  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International urogynecology journal 3 (1992), S. 284-287 
    ISSN: 1433-3023
    Keywords: Cough stress test ; Fluid bridge test ; Genuine stress incontinence ; Stress-Cath®
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The purpose of this study is to assess the positive and negative predictive accuracy of the Stress-Cath® (Continental Pharmaceuticals, UK) as compared to single channel cystometry and a standing cough stress test in the diagnosis of genuine stress incontinence. Twenty-eight women were evaluated for incontinence by single-channel cystometry and a standing cough stress test at cystometric capacity. These same 28 women also underwent a modified fluid bridge test, using a device known as Stress-Cath®. This catheter is able to detect urine in the proximal urethra. The data demonstrated that the Stress-Cath® was 81.3% sensitive and 83.3% specific for the diagnosis of genuine stress incontinence as determined by the simplified urodynamic evaluation. The Stress-Cath® had a positive predictive rate of 86.6% and a negative predictive rate of 76.9%. Its false positive rate was 16.7% and false-negative rate was 18.7%. The Stress-Cath® is relatively insensitive in diagnosing genuine stress incontinence.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 455-465 
    ISSN: 0886-9383
    Keywords: Correspondence analysis ; Cluster analysis ; Optimization ; Eigenanalysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Carey et al. utilized principal components analysis (PCA) to analyze frequency shift data obtained from piezoelectric sensors formed by coating quartz crystals with 27 different GC stationary phases and tested using 14 analytes. The objective of the analysis was to determine an optimal reduced set of coatings for detection of the analytes. The results were correlated with those obtained from cluster analysis. In this paper the data are re-analyzed using correspondence analysis (CA). The advantage of using CA include a symmetric treatment of sensor coatings and analytes and better identification of the representation of the analytes in terms of the detection components. The results obtained by the conjunctive use of PCA, a varimax rotation and cluster analysis were obtained by CA.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 40 (1990), S. 595-611 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Corona discharge (CD) treated polyethylene films were examined using X-ray photoelectron spectroscopy (XPS) and a variety of chemical derivatization techniques. The composition of the CD-treated surfaces were found to be relatively unaffected by aging at temperatures between 70 and 80°F. Ink adhesion testing of films treated under progressively more serve conditions indicated the efficiency of adhesion varied directly with the severity of treatment. Derivatization of CDtreated polyethylene films with pentaflurophenylhydrazine (PFPH) resulted in the formation of a stable hydrazone complex. The PFPH complex extends the detection limit for enolizable carbonyl groups ca. eight-fold and provides relative quantitation of the number of these groups on variously treated polyethylenes. Formation of the hydrazone complex destroyed ink adhesion, indicating that the complex had blocked the site responsible for chemical bonding to the ink. Adhesion of water-soluble printing inks to CD-treated polyethylene is a direct consequence of hydrogen bonding between enolic hydroxyls on the polymer surface and carbonyl groups of the ink.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...