Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Chemistry  (3)
  • Effects of CO  (1)
  • Intestinal Transport  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 289 (1975), S. 217-227 
    ISSN: 1432-1912
    Schlagwort(e): Digitoxin ; Intestinal Transport ; Dose Dependence ; Functional Asymmetry
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary On everted jejunal segments of mice the transfer and tissue uptake of 3H-digitoxin, over a concentration range from 2×10−10–1×10−4M, was investigated from the mucosal (“m”) to the serosal (“s”) side as well as in the opposite direction. 1. The time course of the absorption of 3H-digitoxin and some other compounds investigated (glucose, urea, p-aminohippurate) gave evidence of functional integrity throughout the 75 min-periods of the experiments. 2. When 3H-digitoxin was applied to the mucosal side the permeability coeffcient showed a dose-dependent increase but returned to lower values at higher concentrations. When 3H-digitoxin was administered to the serosal side the permeability coefficient showed a dose-dependent decrease at high concentrations. The ratio of both coefficients “m” → “s”/“s” → “m” increased dose-dependently from 0.4–2.6. 3. The uptake of 3H-digitoxin — applied on the serosal side — into the tissue was independent of dose. However, having administered 3H-digitoxin on the mucosal side the tissue accumulation was 2–5 fold higher and the tissue/medium (T/M) ratio increased within the concentration range from 3.0–9.0. 4. Under DNP (1 mM) the asymmetry and dose dependence of the permeability and tissue uptake of 3H-digitoxin observed in controls were almost abolished. Therefore it is likely that the transfer of 3H-digitoxin in the intestine involves a mechanism more complex than simple diffusion. The existence of more than a two compartment system and/or the contribution of an active transport mechanism is suggested.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-0738
    Schlagwort(e): Acute CO Intoxication ; Venous Oxygen Pressure ; Blood Sugar Concentration ; High (Atmospheric) Pressure ; Effects of CO ; Akute Kohlenoxidvergiftung ; Venöser Sauerstoffdruck ; Blutzuckerverhalten ; Überdruck ; Spezifische Kohlenoxidwirkungen
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung In drei Versuchsreihen an Kaninchen werden nach 1stündiger Einwirkung hoher CO-Konzentrationen unter normalem und erhöhtem Luftdruck Blutzucker, Kohlenoxidhämoglobingehalt (COHb) und Sauerstoff-Partialdruck (pO2) in der V. jugularis gemessen. Hierzu werden analoge Versuche mit reinem Sauerstoffmangel, erzielt durch 1stündige Einwirkung von Sauerstoff-Stickstoffgemischen, in Beziehung gesetzt. Bei 2000 ppm CO in der Einatmungsluft steigt unter normalem atmosphärischen Druck im Mittel von 22 Versuchen der Blutzucker nach 1 Std um 87 % gegenüber dem Ausgangswert von 98,5 mg- % an. Der Sauerstoffdruck im venösen Blut fällt von etwa 45 Torr bereits nach 10 min auf die Hälfte ab und erreicht den Endwert von 9,5 Torr O2 schon nach 30 min. Der sich ebenfalls rasch einstellende COHb-Endwert beträgt 47,9 % im Mittel. Bei Einatmung eines Luftgemisches mit 2000 ppm CO unter einem Druck von 4 ata steigt der Blutzucker trotz annähernd gleichem COHb (43,1 % im Mittel) und etwa gleichem pCO im Gewebe nicht an. Hierbei ist von Bedeutung, daß der venöse pO2 nur auf einen Endwert von 20 Torr absinkt. Die Endwerte für pO2 und COHb sind bereits nach 10 min erreicht. Durch Inhalation eines sauerstoffarmen Stickstoff-Luftgemisches (4 bis 6 Vol- % O2 in der Einatmungsluft) läßt sich der venöse pO2-Abfall der ersten Versuchsreihe mit 2000 ppm CO in Luft unter 1 ata nachahmen. Es zeigt sich, daß pO2 auf etwa 10 Torr absinkt, während der Blutzucker um 100 % gegenüber dem Ausgangswert ansteigt. Nach diesen Untersuchungen scheint der Blutzuckeranstieg bei akuter CO-Vergiftung nicht spezifisch durch den CO-Gehalt von Blut und Geweben, sondern durch den unspezifischen Sauerstoffmangel der Gewebe — als Folge der hypoxischen Wirkung des Kohlenoxids — verursacht zu sein.
    Notizen: Abstract In rabbits, exposed to high CO concentration at normal and increased atmospheric pressure for 1 h, we investigated the effects of CO intoxication of the level of blood sugar, on carboxyhemoglobin (COHb) concentration in blood and on the partial pressure of oxygen (pO2) in jugular venous blood. Analogous experiments were performed with rabbits exposed for 1 h to oxygen deficiency produced by breathing a mixture of oxygen and nitrogen. In animals exposed to 2000 ppm CO under normal atmospheric pressure the level of blood sugar increases after 1 h from 98,5 mg- % to 184 mg- % (mean value of 22 experiments). The partial pressure of oxygen in venous blood decreases within 10 min from 45 torr to about 23 torr and reaches a final value of 9,5 torr O2 after 30 min. The final value of COHb (mean value 47,5 %) is also reached within a short time. Breathing 2000 ppm CO under 4 ata the blood sugar concentration does not increase in spite of about the same CO Hb concentration (mean value 43,1 %) and similar pCO values at the same time. The venous pO2 decreases only to a final value of 20 torr. The final values of pO2 and CO Hb are reached within only 10 min. Breathing mixture of nitrogen and air (4 to 6 % O2 per volume) the venous decrease of pO2 is similar to effects described in the first series with 2000 ppm CO at 1 ata: decrease of pO2 to about 10 torr and increase of blood sugar of about 100% compared to the initial value were observed. These results support the hypothesis that the increase of blood sugar after carbon monoxide intoxication is induced by the nonspecific oxygen deficiency of the organism — caused by CO-poisoning — and is therefore not primarily specific for the CO concentration of blood and tissue.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 340 (1965), S. 1-15 
    ISSN: 0044-2313
    Schlagwort(e): Chemistry ; Inorganic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Beschreibung / Inhaltsverzeichnis: Low-polymeric, cyclic and linear methyl- and phenylsiloxanes are split in methanolic solution by hydrogen iodide. The velocity of the splitting reaction can be determined quantitatively by titration with Karl Fischer's reagent of the silanol groups formed during the process of splitting. The splitting reaction is of the first order and takes place in accordance with the type of an SN 1 reaction.The speed of this acidolytic splitting is very different for the various siloxanes depending on substitution and molecular structure. The influence of the donor-acceptor properties of the substituents as well as of the siloxane bond angle SiOSi on the splittability is discussed.
    Notizen: Niederpolymere, cyclische und lineare Methyl- und Phenylsiloxane werden in methanolischer Lösung mit Jodwasserstoff gespalten. Die Geschwindigkeit der Spaltungsreaktion läßt sich durch Titration der bei der Spaltung entstehenden Silanolgruppen mit Karl-Fischer-Reagenz quantitativ bestimmen. Die Spaltungsreaktion ist 1. Ordnung und verläuft nach dem Typ einer SN 1-Reaktion.Die Geschwindigkeit der acidolytischen Spaltung ist bei verschiedenen Siloxanen je nach der Substitution und der Molekülstruktur sehr unterschiedlich. Der Einfluß der Donator-Acceptoreigenschaften der Substituenten sowie des Siloxanbindungswinkels SiOSi auf die Spaltbarkeit wird diskutiert.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 76 (1964), S. 273-274 
    ISSN: 0044-8249
    Schlagwort(e): Chemistry ; General Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 1 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Angewandte Chemie International Edition in English 3 (1964), S. 310-310 
    ISSN: 0570-0833
    Schlagwort(e): Chemistry ; General Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 1 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...