  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Bedside laboratory analyzes ; Blutgasanalyse ; Kartusche EG7+ ; Hkt/HLM ; i-STAT Analyzer ; Key words Bedside laboratory analyse ; Blood gas tension ; Cartidge EG7+ ; Hct/CPB ; i-STAT analyser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Exact and quick measurements of basic laboratory parameters are important in selected patients in the perioperative period. Depending on the capabilities of a hospital’s central laboratory, the anaesthesiologist may only obtain such laboratory tests after unacceptable delays. This problem may be overcome by a new bedside measurement device that has become available from i-STAT Corporation, Princeton, USA. The hand-held, battery-driven analyser accepts blood specimens that are injected into a disposable cartridge (EG7+) and measures acidity, blood gas tensions, haematocrit, and electrolytes. The aim of this study was to determine the accuracy of such measurements by comparing them with measurements obtained by conventional laboratory test methods. Methods: Heparinised arterial blood specimens were collected in duplicate from 49 surgical patients. Measurements of ionised calcium (Ca), sodium (Na), potassium (K), pH, pCO2, pO2, base excess (BE), haematocrit (Hct), and haemoglobin (Hb) obtained by the i-STAT analyser were compared with measurements from the calibrated analysers ABL 615 and EML 100 (Radiometer, Copenhagen). Because the i-STAT analyser calculates the Hb concentration from a conductometrically measured Hct, 19 blood specimens were centrifuged in order to compare test results with conventionally obtained Hct and Hb values. As the Hct test sensitivity with the i-STAT changes with diluted blood due to its low albumin concentration, Hct and Hb measurements during cardio-pulmonary bypass (CPB) must be corrected by activating an analyser-implemented correction algorithm (Hct/CPB and Hb/CPB). Correlation analysis was performed between conventional measurements and i-STAT values (Ca, Na, K, Hct, pCO2, pO2), between values that the i-STAT analyser derives (Hb, HCO3, BE) and conventionally obtained results, and between normal and CPB-corrected Hct and Hb values. Accuracy was judged according to the national quality standard, whic h requires test results to lie within the 95% confidence interval of conventional tests. Results: Each blood specimen was analysed: erroneous results or technical failures did not occur. Measurement of one set of i-STAT values required 2.5 min. Correlation coefficients (r) between conventional and i-STAT results were: 0.85 for CA, 1.0 for K; 0.86 for Na; 0.99 for pH; 0.98 for pCO2; 0.99 for pO2; 0.93 for HCO3; 0.93 for BE; 0.46 for Hb values not corrected for CPB and 0.95 for CPB-corrected Hb; and 0.74 for Hct values not corrected for CPB and 0.98 for CPB-corrected Hct. The correlation coefficient for Hct between centrifuged and CPB-uncorrected i-STAT values was 0.81 and that for CPB-corrected values was 0.98. National accuracy requirements were not met for tests of: Ca (by 0.02 mmol/l); pH (by 0.01); pO2 including hyperoxic values (by 26.7 mmHg, but were met for pO2 values 〈200 mmHg); Hb (by 1.6 g/dl); Hb/CPB (by 0.8 g/dl); and Hct (by 6.5%, but were met for Hct/CPB values). All other tests fulfilled the required standards. Conclusion: This analyser is easy to use, reliable, and portable, and therefore suitable for the operating room, for analyses during emergencies, on peripheral wards, for preclinical screening, or at times when availability of lab tests is time-consuming or limited. The test accuracy for electrolytes, blood gases, and Hb is high enough to justify routine use of the i-STAT analyser in clinical practice. That the nationally required quality standards for Ca, pH, and Hb were not met is not of importance because the measured deviation was too small to have clinical relevance. When analysing diluted blood with a low Hct and low oncotic pressure, it is important to activate the analyser’s correction algorithm „CPB”, because the obtained results will then comply with the required accuracy.
    Notes: Zusammenfassung Zielsetzung und Methoden: In der chirurgischen Operationseinheit und Intensivstation der Universitätsklinik wurden bei 49 Patienten arterielle Blutproben entnommen und simultan mit dem i-STAT Analyzer (Kartusche EG7+) und einem Referenzgerät ausgewertet. Die Kartusche EG7+ ermittelt die Parameter ionisiertes Kalzium, Kalium, Natrium, pH, pCO2, pO2 und Hämatokrit. HCO3, BE, SO2 und Hb werden aus diesen Daten errechnet. Der Hkt bzw. das Hb kann mit der speziellen Anpassung (HLM) für erniedrigtes Serumprotein z.B. während kardiopulmonalem Bypass unter Herz-Lungenmaschine (HLM) korrigiert werden. Ergebnisse: Mit dem Referenzgerät ABL 615 und EML 100 wurden die Korrelationen (r) für ionisiertes Kalzium (r=0,85), Kalium (r=1,0), Natrium (r=0,86), pH (r=0,99), pCO2 (r=0,98), pO2 (r=0,99), HCO3 (r=0,93), BE (r=0,93), Hb (r=0,46), Hb/HLM (r=0,95), Hkt (r=0,81) und Hkt/HLM (r=0,98) ermittelt. Die 95% Binominalverteilung der Differenzen lagen beim Kalium, Natrium, pCO2, pO2 und Hkt/HLM innerhalb der Vorgaben zur Qualitätssicherung der Bundesärztekammer. Die Meßwerte für ionisiertes Kalzium, pH und Hb/HLM lagen zwar außerhalb der empfohlenen Toleranzen der BÄK, sind aber für den klinischen Gebrauch akzeptabel. Im anästhesiologischen Bereich sollte zur Hkt- oder Hb Bestimmung immer die „HLM” Anpassung für erniedrigtes Serumprotein programmiert werden. Zusammenfassung: Der einfache Gebrauch, die Transportierbarkeit und eine Analysezeit der Blutproben von ca. 2,5 min sowie die Wirtschaftlichkeit bei geringstem Wartungsaufwand prädestinieren dieses Gerät auch für innerklinische Notfälle, z.B. im Schockraum oder auf Normalstation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 48 (1999), S. 142-156 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Tracheotomie: perkutan ; chirurgisch ; Komplikationen ; Ergebnisse ; Kosten ; Key words Tracheostomy: percutaneous ; surgical ; Complications ; Results ; Costs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Tracheostomy is one of the oldest surgical procedures and in the past decades has become the method of choice in the management of patients requiring long-term mechanical ventilation. At present, several alternatives exist to conventional surgical tracheostomy, such as the percutaneous dilatational techniques according to Ciaglia (PDT), Griggs (GWDF), and Schachner (Rapitrach). In particular, PDT according to Ciaglia which was introduced in 1985, has been recognized as an equally safe, but less expensive procedure than conventional tracheostomy. Fantoni’s translaryngeal percutaneous technique is another new and safe procedure, which was first performed in 1996. Nonetheless, we believe that percutaneous procedures should only be performed by experienced physicians who are well-trained in both endotracheal intubation and mask ventilation. Furthermore, the capacity to perform surgical tracheostomy immediately in case of complications should be given. Only if the contraindications are carefully observed, will these new procedures retain their value and benefit in airway management of long-term ventilated patients.
    Notes: Zusammenfassung Die Tracheotomie ist einer der ältesten Eingriffe in der Geschichte der Chirurgie und hat sich in den vergangenen Jahrzehnten zum Verfahren der Wahl im langfristigen Atemwegsmanagement beatmeter Intensivpatienten entwickelt. Alternativ zur klassisch-konventionellen Tracheotomie existieren inzwischen verschiedene Verfahren zur perkutanen Tracheotomie. Hierzu zählen die perkutanen Dilatationstracheotomien nach Ciaglia (PDT), Griggs (GWDF) und Schachner (Rapitrach). Vor allem die 1985 eingeführte PDT nach Ciaglia hat sich gegenwärtig im intensivmedizinischen Bereich als eine sichere und konstenärmere Methode im Vergleich zur chirurgisch durchgeführten Tracheotomie etabliert. Seit 1996 steht mit der translaryngealen Tracheotomie nach Fantoni eine weitere perkutane Technik zur Verfügung, die sich durch eine niedrige Komplikationsrate auszeichnet. Trotz der niedrigen Komplikationsraten der perkutanen Verfahren sollten diese, auch wenn sie rasch erlernbar und technisch wenig aufwendig sind, nur von Ärzten angewendet werden, die die Technik der Reintubation und Maskenbeatmung sicher beherrschen. Auch sollte die Möglichkeit bestehen, ggf. rasch eine konventionelle Tracheotomie durchführen zu können. Nur unter sorgfältiger Beachtung der Kontraindikationen werden die Techniken der perkutanen Tracheotomie ihren Stellenwert behaupten und entsprechende Vorteile für die Patienten bieten können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Perkutane Dilatationstracheotomie ; Ciaglia Blue Rhino ; Komplikationen ; Key words Percutaneous dilatational tracheostomy ; Ciaglia Blue Rhino ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objective: Elective tracheostomy has become an established treatment modality in modern intensive care medicine, and the number of percutaneously performed tracheostomies is steadily increasing. The Ciaglia Blue Rhino (CBR) represents another percutaneous technique in which the tracheostoma is formed by one-step dilation. Our study presents the technique itself and the early clinical experiences. Methods: In 20 adult patients on long-term ventilation, CBR was done. After puncture of the trachea in typical manner, dilation of the tracheostoma was achieved in one single step by means of a curved dilator with a special hydrophilic coating. Then, the tracheostomy tube was inserted over a curved loading dilator. Practicability and safety were determined as well as gas exchange during the procedure by means of arterial blood gas samples. Results: As a result of the dilator’s hydrophilic coating, dilation of the tracheostoma was rapidly achieved within 152±22 s, virtually free from resistance of the trachea or the cervical tissues. Complications such as bleeding, aspiration or postoperative infection of the stoma were not noted in any of our patients. Fractures of isolated tracheal cartilage rings were seen in 5 patients, however, no therapeutic intervention was necessary. In terms of perioperative gas exchange, pre- and postoperative levels of FiO2, PaO2, PaCO2 and the oxygenation index (PaO2/FiO2) did not change significantly. Conclusions: Based on our early clinical experience, Ciaglia Blue Rhino represents a new method that may combine the typical advantages of each of the other techniques for percutaneous tracheostomy (i.e. Ciaglia, Griggs, Fantoni) in one single technique. This method is distinguished by a high level of safety and practicability. However, further comparative trials need to be done before a definitive judgement can be made.
    Notes: Zusammenfassung Fragestellung: Die elektive Tracheotomie stellt in der modernen Intensivmedizin einen festen Bestandteil der Beatmungstherapie dar und wird zunehmend perkutan durchgeführt. Mit der Ciaglia Blue Rhino (CBR) steht nunmehr eine weitere perkutane Technik zur Verfügung, bei der zur Anlage des Tracheostomas nur noch ein einziger Dilatationsschritt erforderlich ist. Ziel der vorliegenden Untersuchung war es, die Technik der CBR und erste klinische Ergebnisse vorzustellen. Methodik: Bei 20 langzeitbeatmeten, erwachsenen Intensivpatienten wurde eine CBR durchgeführt. Nach Punktion der Trachea in typischer Weise erfolgt die Dilatation des Tracheostomas in einem Schritt mittels eines gebogenen Dilatators, der über eine spezielle hydrophile Beschichtung verfügt. Anschließend wird die Trachealkanüle über einen Führungsstab eingeführt. Neben Praktikabilität und Komplikationen der Technik wurde deren Einfluß auf den perioperativen Gasaustausch mittels Blutgasanalysen untersucht. Ergebnisse: Aufgrund der hydrophilen Beschichtung des Dilatators und der damit verbundenen nahezu widerstandslosen Bougierung gelang die Anlage des Tracheostomas im Mittel in 152±22 s. Akut interventionsbedürftige Komplikationen wie Blutungen, Aspiration oder eine postoperative Infektion des Tracheostomas wurden nicht beobachtet. Bei 5 Patienten kam es zu einer Fraktur einzelner Trachealspangen, die jedoch keine therapeutische Konsequenz hatte. Hinsichtlich des perioperativen Gasaustauschs ergaben sich keine Signifikanzen hinsichtlich der prä- und postoperativen Höhen von FiO2, paO2, paCO2 und des Oxygenierungsindex (paO2/FiO2). Schlussfolgerung: Die Ciaglia Blue Rhino-Technik könnte aufgrund dieser ersten klinischen Erfahrungen ein Verfahren darstellen, das die jeweiligen Vorteile der anderen perkutanen Tracheotomietechniken nach Ciaglia, Griggs und Fantoni in sich vereint. Diese weiterentwickelte Technik zeichnet sich durch hohe Praktikabilität und eine sehr rasche und sichere Durchführbarkeit aus. Zur endgültigen Bewertung dieses Verfahrens auch im Hinblick auf Spätkomplikationen müssen jedoch detaillierte Vergleichsstudien folgen.