Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Sevofluran ; Inhalationseinleitung ; Schadstoffbelastung ; Kinderbronchoskopie ; Key words Sevoflurane ; Inhalation induction ; Occupational exposure ; Paediatric bronchoscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract General anaesthetic agents are frequently used for paediatric bronchoscopy. A disadvantage of open-system anaesthesia is the contamination of the working environment. The aim of this study was to determine the exposure of the anaesthesiologist and endoscopist during paediatric bronchoscopy under general anaesthesia in different working environments and to compare these measurements to the currently valid international threshold limits. Materials and methods: Twenty-five children (ASA I–III) scheduled for diagnostic bronchoscopy were included in the study. After inhalational induction, all patients were intubated with a nonflexible bronchoscope and manually ventilated through a side-arm of the bronchoscope. Maintenance of anaesthesia was achieved with sevoflurane (2–3 vol.%) in pure oxygen. Trace concentrations were measured every 90 s in the breathing zones of the operating theatre (OT) personnel by means of a highly sensitive direct-reading instrument (Brüel & Kjaer 1302). The lower detection limit was 0.02 ppm. The investigation was done in an OT with and without air-conditioning and a scavenging system. Results: The mean age of the children was 50.3 months (range: 3–109 months). Ventilation and oxygenation were stable throughout the bronchoscopic procedure. Mean exposure to sevoflurane in the OT without air-conditioning and a scavenging system was over 40 ppm for the anaesthetist and 50 ppm for the endoscopist. All international threshold limit values were exceeded. Peak concentrations higher than 100 ppm could be detected during 40% of the anaesthetics. Conclusion: the main finding of the present study is that under inhalation anaesthesia with sevoflurane for paediatric bronchoscopy, occupational exposure is higher than all known health regulation guidelines permit. Therefore, the use of total intravenous anaesthesia is advocated even in very small infants.
    Notes: Zusammenfassung Die Bronchoskopie bei Kindern mittels volatiler Anästhetika ist ein gängiges und anerkanntes Verfahren. Nachteilig ist allerdings eine Kontamination der Umgebung mit diesen Substanzen. Zielsetzung: Ziel der Untersuchung war es, die Exposition des Personals sowohl in dem vorhandenen Untersuchungsraum in der Pädiatrie als auch unter optimalen lüftungstechnischen Bedingungen im OP Saal hinsichtlich der derzeit gültigen Arbeitsschutzgrenzwerte zu messen. Methodik: 25 Kinder, die für eine diagnostische Bronchoskopie vorgesehen waren, wurden in die Studie eingeschlossen. Nach inhalativer Einleitung wurden die Kinder mit einem starren Bronchoskop intubiert und über eine Bypassöffnung manuell ventiliert. Für die anschließende Gastroskopie wurden die Kinder mit nicht blockbaren Tuben intubiert. Die Narkose wurde mit Sevofluran aufrechterhalten. Die Spurenkonzentrationen wurden mittels eines direktanzeigenden Infrarotspektrometers (Brüel & Kjaer 1302) in den Atemzonen von Pädiater und Anästhesisten gemessen. Die untere Nachweisgrenze betrug für Sevofluran 0,02 ppm, die gemessenen Konzentrationen lagen im Meßbereich des Infrarotspektrometers. Ergebnisse: Das mittlere Alter der Kinder betrug 50,3 Monate (Spannweite 3–109 Monate). Die durchschnittlichen Expositionswerte lagen in dem Raum ohne Klimatechnik für den Anästhesisten deutlich über 40 ppm, für den Pädiater über 50 ppm. Spitzenwerte von Sevofluran über 100 ppm wurden in 40% der Narkosen mehrfach übertroffen. Selbst unter suffizienter Klimatechnik wurden hohe Arbeitsplatzkonzentrationen gemessen. Schlußfolgerung: Arbeitsplatzbelastungen mit Sevofluran können in Räumen mit optimaler Klimatechnik deutlich abgeschwächt werden, obwohl auch dort hohe Arbeitsplatzkonzentrationen nachgewiesen werden konnten. Um ein mögliches Gesundheitsrisiko für Beschäftigte zu minimieren, sollte bei starren Bronchoskopien auf eine total intravenöse Anästhesietechnik ausgewichen werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Bedside laboratory analyzes ; Blutgasanalyse ; Kartusche EG7+ ; Hkt/HLM ; i-STAT Analyzer ; Key words Bedside laboratory analyse ; Blood gas tension ; Cartidge EG7+ ; Hct/CPB ; i-STAT analyser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Exact and quick measurements of basic laboratory parameters are important in selected patients in the perioperative period. Depending on the capabilities of a hospital’s central laboratory, the anaesthesiologist may only obtain such laboratory tests after unacceptable delays. This problem may be overcome by a new bedside measurement device that has become available from i-STAT Corporation, Princeton, USA. The hand-held, battery-driven analyser accepts blood specimens that are injected into a disposable cartridge (EG7+) and measures acidity, blood gas tensions, haematocrit, and electrolytes. The aim of this study was to determine the accuracy of such measurements by comparing them with measurements obtained by conventional laboratory test methods. Methods: Heparinised arterial blood specimens were collected in duplicate from 49 surgical patients. Measurements of ionised calcium (Ca), sodium (Na), potassium (K), pH, pCO2, pO2, base excess (BE), haematocrit (Hct), and haemoglobin (Hb) obtained by the i-STAT analyser were compared with measurements from the calibrated analysers ABL 615 and EML 100 (Radiometer, Copenhagen). Because the i-STAT analyser calculates the Hb concentration from a conductometrically measured Hct, 19 blood specimens were centrifuged in order to compare test results with conventionally obtained Hct and Hb values. As the Hct test sensitivity with the i-STAT changes with diluted blood due to its low albumin concentration, Hct and Hb measurements during cardio-pulmonary bypass (CPB) must be corrected by activating an analyser-implemented correction algorithm (Hct/CPB and Hb/CPB). Correlation analysis was performed between conventional measurements and i-STAT values (Ca, Na, K, Hct, pCO2, pO2), between values that the i-STAT analyser derives (Hb, HCO3, BE) and conventionally obtained results, and between normal and CPB-corrected Hct and Hb values. Accuracy was judged according to the national quality standard, whic h requires test results to lie within the 95% confidence interval of conventional tests. Results: Each blood specimen was analysed: erroneous results or technical failures did not occur. Measurement of one set of i-STAT values required 2.5 min. Correlation coefficients (r) between conventional and i-STAT results were: 0.85 for CA, 1.0 for K; 0.86 for Na; 0.99 for pH; 0.98 for pCO2; 0.99 for pO2; 0.93 for HCO3; 0.93 for BE; 0.46 for Hb values not corrected for CPB and 0.95 for CPB-corrected Hb; and 0.74 for Hct values not corrected for CPB and 0.98 for CPB-corrected Hct. The correlation coefficient for Hct between centrifuged and CPB-uncorrected i-STAT values was 0.81 and that for CPB-corrected values was 0.98. National accuracy requirements were not met for tests of: Ca (by 0.02 mmol/l); pH (by 0.01); pO2 including hyperoxic values (by 26.7 mmHg, but were met for pO2 values 〈200 mmHg); Hb (by 1.6 g/dl); Hb/CPB (by 0.8 g/dl); and Hct (by 6.5%, but were met for Hct/CPB values). All other tests fulfilled the required standards. Conclusion: This analyser is easy to use, reliable, and portable, and therefore suitable for the operating room, for analyses during emergencies, on peripheral wards, for preclinical screening, or at times when availability of lab tests is time-consuming or limited. The test accuracy for electrolytes, blood gases, and Hb is high enough to justify routine use of the i-STAT analyser in clinical practice. That the nationally required quality standards for Ca, pH, and Hb were not met is not of importance because the measured deviation was too small to have clinical relevance. When analysing diluted blood with a low Hct and low oncotic pressure, it is important to activate the analyser’s correction algorithm „CPB”, because the obtained results will then comply with the required accuracy.
    Notes: Zusammenfassung Zielsetzung und Methoden: In der chirurgischen Operationseinheit und Intensivstation der Universitätsklinik wurden bei 49 Patienten arterielle Blutproben entnommen und simultan mit dem i-STAT Analyzer (Kartusche EG7+) und einem Referenzgerät ausgewertet. Die Kartusche EG7+ ermittelt die Parameter ionisiertes Kalzium, Kalium, Natrium, pH, pCO2, pO2 und Hämatokrit. HCO3, BE, SO2 und Hb werden aus diesen Daten errechnet. Der Hkt bzw. das Hb kann mit der speziellen Anpassung (HLM) für erniedrigtes Serumprotein z.B. während kardiopulmonalem Bypass unter Herz-Lungenmaschine (HLM) korrigiert werden. Ergebnisse: Mit dem Referenzgerät ABL 615 und EML 100 wurden die Korrelationen (r) für ionisiertes Kalzium (r=0,85), Kalium (r=1,0), Natrium (r=0,86), pH (r=0,99), pCO2 (r=0,98), pO2 (r=0,99), HCO3 (r=0,93), BE (r=0,93), Hb (r=0,46), Hb/HLM (r=0,95), Hkt (r=0,81) und Hkt/HLM (r=0,98) ermittelt. Die 95% Binominalverteilung der Differenzen lagen beim Kalium, Natrium, pCO2, pO2 und Hkt/HLM innerhalb der Vorgaben zur Qualitätssicherung der Bundesärztekammer. Die Meßwerte für ionisiertes Kalzium, pH und Hb/HLM lagen zwar außerhalb der empfohlenen Toleranzen der BÄK, sind aber für den klinischen Gebrauch akzeptabel. Im anästhesiologischen Bereich sollte zur Hkt- oder Hb Bestimmung immer die „HLM” Anpassung für erniedrigtes Serumprotein programmiert werden. Zusammenfassung: Der einfache Gebrauch, die Transportierbarkeit und eine Analysezeit der Blutproben von ca. 2,5 min sowie die Wirtschaftlichkeit bei geringstem Wartungsaufwand prädestinieren dieses Gerät auch für innerklinische Notfälle, z.B. im Schockraum oder auf Normalstation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Perkutane Dilatationstracheotomie ; Ciaglia Blue Rhino ; Komplikationen ; Key words Percutaneous dilatational tracheostomy ; Ciaglia Blue Rhino ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objective: Elective tracheostomy has become an established treatment modality in modern intensive care medicine, and the number of percutaneously performed tracheostomies is steadily increasing. The Ciaglia Blue Rhino (CBR) represents another percutaneous technique in which the tracheostoma is formed by one-step dilation. Our study presents the technique itself and the early clinical experiences. Methods: In 20 adult patients on long-term ventilation, CBR was done. After puncture of the trachea in typical manner, dilation of the tracheostoma was achieved in one single step by means of a curved dilator with a special hydrophilic coating. Then, the tracheostomy tube was inserted over a curved loading dilator. Practicability and safety were determined as well as gas exchange during the procedure by means of arterial blood gas samples. Results: As a result of the dilator’s hydrophilic coating, dilation of the tracheostoma was rapidly achieved within 152±22 s, virtually free from resistance of the trachea or the cervical tissues. Complications such as bleeding, aspiration or postoperative infection of the stoma were not noted in any of our patients. Fractures of isolated tracheal cartilage rings were seen in 5 patients, however, no therapeutic intervention was necessary. In terms of perioperative gas exchange, pre- and postoperative levels of FiO2, PaO2, PaCO2 and the oxygenation index (PaO2/FiO2) did not change significantly. Conclusions: Based on our early clinical experience, Ciaglia Blue Rhino represents a new method that may combine the typical advantages of each of the other techniques for percutaneous tracheostomy (i.e. Ciaglia, Griggs, Fantoni) in one single technique. This method is distinguished by a high level of safety and practicability. However, further comparative trials need to be done before a definitive judgement can be made.
    Notes: Zusammenfassung Fragestellung: Die elektive Tracheotomie stellt in der modernen Intensivmedizin einen festen Bestandteil der Beatmungstherapie dar und wird zunehmend perkutan durchgeführt. Mit der Ciaglia Blue Rhino (CBR) steht nunmehr eine weitere perkutane Technik zur Verfügung, bei der zur Anlage des Tracheostomas nur noch ein einziger Dilatationsschritt erforderlich ist. Ziel der vorliegenden Untersuchung war es, die Technik der CBR und erste klinische Ergebnisse vorzustellen. Methodik: Bei 20 langzeitbeatmeten, erwachsenen Intensivpatienten wurde eine CBR durchgeführt. Nach Punktion der Trachea in typischer Weise erfolgt die Dilatation des Tracheostomas in einem Schritt mittels eines gebogenen Dilatators, der über eine spezielle hydrophile Beschichtung verfügt. Anschließend wird die Trachealkanüle über einen Führungsstab eingeführt. Neben Praktikabilität und Komplikationen der Technik wurde deren Einfluß auf den perioperativen Gasaustausch mittels Blutgasanalysen untersucht. Ergebnisse: Aufgrund der hydrophilen Beschichtung des Dilatators und der damit verbundenen nahezu widerstandslosen Bougierung gelang die Anlage des Tracheostomas im Mittel in 152±22 s. Akut interventionsbedürftige Komplikationen wie Blutungen, Aspiration oder eine postoperative Infektion des Tracheostomas wurden nicht beobachtet. Bei 5 Patienten kam es zu einer Fraktur einzelner Trachealspangen, die jedoch keine therapeutische Konsequenz hatte. Hinsichtlich des perioperativen Gasaustauschs ergaben sich keine Signifikanzen hinsichtlich der prä- und postoperativen Höhen von FiO2, paO2, paCO2 und des Oxygenierungsindex (paO2/FiO2). Schlussfolgerung: Die Ciaglia Blue Rhino-Technik könnte aufgrund dieser ersten klinischen Erfahrungen ein Verfahren darstellen, das die jeweiligen Vorteile der anderen perkutanen Tracheotomietechniken nach Ciaglia, Griggs und Fantoni in sich vereint. Diese weiterentwickelte Technik zeichnet sich durch hohe Praktikabilität und eine sehr rasche und sichere Durchführbarkeit aus. Zur endgültigen Bewertung dieses Verfahrens auch im Hinblick auf Spätkomplikationen müssen jedoch detaillierte Vergleichsstudien folgen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 48 (1999), S. 142-156 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Tracheotomie: perkutan ; chirurgisch ; Komplikationen ; Ergebnisse ; Kosten ; Key words Tracheostomy: percutaneous ; surgical ; Complications ; Results ; Costs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Tracheostomy is one of the oldest surgical procedures and in the past decades has become the method of choice in the management of patients requiring long-term mechanical ventilation. At present, several alternatives exist to conventional surgical tracheostomy, such as the percutaneous dilatational techniques according to Ciaglia (PDT), Griggs (GWDF), and Schachner (Rapitrach). In particular, PDT according to Ciaglia which was introduced in 1985, has been recognized as an equally safe, but less expensive procedure than conventional tracheostomy. Fantoni’s translaryngeal percutaneous technique is another new and safe procedure, which was first performed in 1996. Nonetheless, we believe that percutaneous procedures should only be performed by experienced physicians who are well-trained in both endotracheal intubation and mask ventilation. Furthermore, the capacity to perform surgical tracheostomy immediately in case of complications should be given. Only if the contraindications are carefully observed, will these new procedures retain their value and benefit in airway management of long-term ventilated patients.
    Notes: Zusammenfassung Die Tracheotomie ist einer der ältesten Eingriffe in der Geschichte der Chirurgie und hat sich in den vergangenen Jahrzehnten zum Verfahren der Wahl im langfristigen Atemwegsmanagement beatmeter Intensivpatienten entwickelt. Alternativ zur klassisch-konventionellen Tracheotomie existieren inzwischen verschiedene Verfahren zur perkutanen Tracheotomie. Hierzu zählen die perkutanen Dilatationstracheotomien nach Ciaglia (PDT), Griggs (GWDF) und Schachner (Rapitrach). Vor allem die 1985 eingeführte PDT nach Ciaglia hat sich gegenwärtig im intensivmedizinischen Bereich als eine sichere und konstenärmere Methode im Vergleich zur chirurgisch durchgeführten Tracheotomie etabliert. Seit 1996 steht mit der translaryngealen Tracheotomie nach Fantoni eine weitere perkutane Technik zur Verfügung, die sich durch eine niedrige Komplikationsrate auszeichnet. Trotz der niedrigen Komplikationsraten der perkutanen Verfahren sollten diese, auch wenn sie rasch erlernbar und technisch wenig aufwendig sind, nur von Ärzten angewendet werden, die die Technik der Reintubation und Maskenbeatmung sicher beherrschen. Auch sollte die Möglichkeit bestehen, ggf. rasch eine konventionelle Tracheotomie durchführen zu können. Nur unter sorgfältiger Beachtung der Kontraindikationen werden die Techniken der perkutanen Tracheotomie ihren Stellenwert behaupten und entsprechende Vorteile für die Patienten bieten können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Intensivmedizin ; Perkutane Dilatationstracheotomie ; Translaryngeale Tracheotomie ; Komplikationen ; Infektion ; Key words Intensive care medicine ; Percutaneous dilatational tracheostomy ; Translaryngeal tracheostomy ; Complications ; Infection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Tracheostomy is considered the airway management of choice in long-term ventilated ICU patients. In the last few years, percutaneous dilatational tracheostomy (PDT) has been established as an attractive and safe alternative to conventional open tracheostomy. Recently, there is another percutaneous technique according to Fantoni with translaryngeal airway access (TLT) available. Our study seeks to evaluate TLT in terms of complications and practicability. In 47 patients of our surgical ICU, elective TLT was performed. Mean operative time was 9.8±10.9 (range 6–27) minutes. Severe complications, such as bleeding, aspiration or infection of the tracheostoma have never been noted. A slight detoriation of arterial oxygen tension occured in 25 patients intraoperatively, demanding to rise the concentration of inspired oxygen temporarily. However, no patient became hypoxic during the procedure.Since during the procedure gas exchange may worsen, TLT should not be employed in patients whose inspired oxygen concentration exceeds 80%. Despite the fact that severe complications associated with TLT have recently not yet been reported, physicians who perform TLT should be well-trained in the technique of conventional open tracheostomy, too. According to our present data, TLT seems to be an attractive and safe alternative to PDT. Nevertheless, for a definiteve evaluation of TLT, further investigations in larger groups of patients and in the long term seem to be necessary.
    Notes: Zusammenfassung Einleitung: Die Tracheotomie langzeitbeatmeter Intensivpatienten hat sich als integrierter Bestandteil der Beatmungsbehandlung etabliert. In den vergangen Jahren konnte sich zunehmend die perkutane Dilatationstracheotomie (PDT) als komplikationsarme Alternative zur konventionellen chirurgischen Tracheotomie durchsetzen. Seit kurzem steht mit der translaryngealen Tracheotomie (TLT) nach Fantoni ein weiteres perkutanes Verfahren zur Verfügung. Ziel der vorliegenden klinischen Untersuchung war es, die Ergebnisse nach elektiver TLT bei chirurgischen Intensivpatienten bezüglich Komplikationsrate und Praktikabilität aufzuzeigen. Methodik und Ergebnisse: Bei 47 Intensivpatienten wurde die TLT nach Fantoni durchgeführt. Die Operationszeit betrug 9,8±10,9 (Range 6–27) min. Akut interventionsbedürftige Komplikationen wie Blutungen, Aspiration oder Infektion des Tracheostomas traten bei keinem Patienten auf. Eine passagere Verschlechterung des paO2 während des Eingriffs erforderte bei 25 Patienten eine vorübergehende Erhöhung der inspiratorischen Sauerstoffkonzentration, ohne daß das Auftreten einer Hypoxie beobachtet wurde. Schlußfolgerungen: Da es bei der Durchführung der TLT zu einer Verschlechterung der Oxygenierungssituation kommen kann, sollte dieses Verfahren nur bei Patienten mit einer FiO2 von weniger als 0,8 durchgeführt werden. Bei der TLT sollte der Arzt mit der Anatomie gut vertraut sein und über Erfahrung mit der konventionellen Tracheostomie verfügen, um eventuelle Komplikationen rasch und sicher behandeln zu können. Aufgrund unserer Ergebnisse scheint die TLT eine sichere und komplikationsarme Alternative zur PDT darzustellen. Dennoch müssen zur endgültigen Bewertung der TLT weitere Untersuchungen an größeren Patientenkollektiven und über einen längeren Beobachtungszeitraum folgen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 49 (2000), S. 592-608 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Minimalinvasive Herzchirurgie ; “off-pump”-Herzchirurgie ; Port-Access-Technik ; Roboterunterstüzte Herzchirurgie ; Anästhesiologisches Management ; Key wordsMinimally-invasive cardiac surgery ; Port-access technique ; “Off-pump coronary artery surgery” ; Anesthetic management
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract When heart-lung machines made extracorporeal circulation possible in the fifties, cardiac surgeons gained virtually unrestricted access to the resting, motionless heart. Valve repair and reconstruction, in particular, made great progress as a result of extracorporeal circulation. While the distinct advantages of extracorporeal circulation for cardiosurgery remain undisputed, awareness of the significant perioperative risks of extracorporeal circulation for the patient has been increasing in recent years. This has lead to an interest in alternative cardiosurgical techniques avoiding extracorporeal circulation. Inspired by minimally-invasive procedures in abdominal surgery, cardiosurgical instruments as well as surgical techniques of access to the heart and large thoracic vessels were systematically modified leading to today's minimally-invasive cardiosurgical procedures such as off-pump coronary artery bypass grafting on the beating heart. Similarly, in the field of cardiac valve repair, new cannulation techniques for instituting extracorporeal circulation make median sternotomy unnecessary. The developments described above have lead to the recent introduction of robot-assisted techniques with or without extracorporeal circulation, which are expected to make possible in the near future the performance of the whole range of cardiosurgical procedures with minimal surgical trauma. The introduction of the new techniques has changed the intraoperative responsibilities of the anesthesiologist. The present article will therefore describe both the new surgical techniques as well as the new tasks required of the anesthesiologist, in particular with regard to cannulation and monitoring. Since a number of terms in minimally-invasive cardiosurgery are not precisely defined, a clear description of the various surgical techniques is also provided.
    Notes: Zusammenfassung Mit der Einführung der extrakorporalen Zirkulation mittels Herz-Lungen-Maschine (HLM) in den 50er Jahren eröffnete sich dem Herzchirurgen die Möglichkeit der weitgehend uneingeschränkten chirurgischen Manipulation am ruhenden Herzen. So wurden in der Herzklappenchirurgie dank der HLM die therapeutischen Methoden der Rekonstruktion pathologisch veränderter Klappen entscheidend weiterentwickelt. Trotz der unbestrittenen Vorteile induziert die HLM auch einen inflammatorischen Gesamtschaden im Organismus. Aus diesem Grund wurden in den letzten Jahren, nicht zuletzt vor dem Hintergrund reduzierter finanzieller Resourcen, intensiv alternative chirurgische Techniken unter Umgehung der HLM vorangetrieben. Parallel hierzu wurde versucht, unter Zuhilfenahme spezieller chirurgischer Instrumente den operativen Zugangsweg zum Herzen und zu den großen intrathorakalen Gefäßen zu minimieren. Daraus entwickelte sich die heutige minimalinvasive Herzchirurgie, die einerseits, unter Umgehung der extrakorporalen Zirkulation, Operationen der Koronargefäße am schlagenden Herzen und andererseits herzchirurgische Verfahren bei deutlich minimiertem chirurgischem Trauma ermöglicht, wobei die Einführung neuartiger herzferner Kanülierungstechniken zum Anschluß der HLM entscheidend mit beigetragen hat. Derzeitiger Endpunkt der Entwicklung sind komplett endoskopische roboterunterstßtzte Operationstechniken. Mit der Einfßhrung der genannten minimalinvasiven herzchirurgischen Verfahren, die zu teilweise deutlich verlängerten Operationszeiten führen, hat sich auch das Anforderungsprofil an den Anästhesisten erheblich verändert. Spezielle Kanülierungstechniken, Ein-Lungen-Ventilation, und die Bedienung der transösophagealen Echokardiographie sind Aufgaben, mit denen der Anästhesist im Rahmen minimalinvasiver herzchirurgischer Verfahren konfrontiert wird. Im Nachfolgenden werden sowohl die veränderten chirurgischen Techniken als auch die hierdurch bedingten veränderten anästhesiologischen Maßnahmen und Anforderungen (insbesondere im Bereich des Monitorings und der Kanülierungsmaßnahmen) näher beschrieben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 6 (1927), S. 2417-2419 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 13 (1999), S. 13-18 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Komplikationen – Kalziumantagonisten – Diltiazem – aortokoronare Bypass-Operation – Anästhesie – myokardiale Ischämien ; Key words complication – calcium entery blockers – diltiazem – coronary artery bypass graft surgery – myocardial ischemia – anesthesia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Introduction: We investigated the incidence of postoperative chest tube bleeding, administration of blood products, and changes in coagulation tests in patients with diltiazem (DIL) administration for reduction of myocardial ischemic episodes during elective CABG. Methods: We retrospectively analyzed the surgical and ICU records of CABG patients who had recieved DIL (27 pats.) or nitroglycerin (NTG; 26 pats.) or a combination thereof (COM; 25 pats.). Data investigated included the amount of postoperative chest tube bleeding (CTB), frequency of administration of packed red blood cells (RBC) and fresh frozen plasma (FFP), and changes in hemoglobin (Hb), thrombocyte (Th) levels as well as changes in prothrombin- (PT) and partial thromboplastine time (PTT). Results: There were no significant differences among the three groups with regard to biometrical or operative data. The amount of CTB as well as the use of RBC and FFP were not significantly different between the groups. Also, there were no significant differences with regard to Hb or Th and PT or PTT, both in the early phase after the operation in ICU as well as after 24 hours in the ICU. Conclusion: The perioperative administration of the calcium entery blocker DIL reduces the incidence of myocardial ischemia during CABG surgery. This administration during CABG surgery does not increase the risk of postoperative bleeding. As compared to NTG, DIL does not have negative effects on Hb and Th levels or the commonly used coagulation parameters in the first 24 hours in the ICU after CABG surgery.
    Notes: Zusammenfassung Wir analysierten das Auftreten postoperativer Nachblutungen, die Häufigkeit der Gabe von Blutkonserven (EK) bzw. frisch gefrorenem Plasma (FFP) sowie die Veränderungen gerinnungsspezifischer Laborparameter bei Patienten mit koronarer Herzkrankheit während der Administration von Diltiazem (DIL) zur Prophylaxe myokardialer Ischämien bei elektiver aortokoronarer Bypass-Operation (ACB-OP). Methoden Retrospektiv wurden die OP-/Intensivstations-Protokolle der Patienten (Pat.) nach einer perioperativen Prophylaxe mit DIL (27 Pat.), Nitroglycerin (NTG; 26 Pat.) bzw. einer Kombination von DIL/NTG (25 Pat.) bezüglich der postoperativen Thoraxdrainagenmenge, der Häufigkeit der EK- bzw. FFP-Gabe, der Veränderungen des Hämoglobins (Hb), der Thrombozytenzahl (Th), der Thromboplastin- (TPZ) und part. Thromboplastin-Zeit (PTT) präoperativ, bei der Aufnahme, sowie 24 h nach der Aufnahme auf der Intensivstation analysiert. Ergebnisse Bezüglich der postoperativen Thoraxdrainagenmenge sowie der Häufigkeit der EK- bzw. FFP-Gabe konnte zwischen den unterschiedlichen Behandlungsgruppen kein signifikanter Unterschied nachgewiesen werden. Auch die Laborparameter Hb, Th, TPZ und PTT bei der Aufnahme bzw. nach 24 h auf der Intensivstation zeigten keine signifikanten Unterschiede. Schlußfolgerung Die perioperative Gabe des Kalziumantagonisten DIL zur myokardialen Ischämieprophylaxe während der ACB-OP erhöht nicht das postoperative Nachblutungsrisiko. Im Vergleich zur perioperativen Gabe von Nitroglycerin werden die Hb-Konzentration sowie wichtige Gerinnungsparameter durch Diltiazem während ACB-OP nicht negativ beeinflußt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 13 (1999), S. 159-163 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Transmyokardiale Laserrevaskularisation ; Hohes Risiko ; Koronare Herzkrankheit ; Intraaortale Ballonpumpe ; Key words Transmyocardial laserrevascularization ; high risk ; coronary artery disease ; intra-aortic balloon pump
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary This case report deals with a patient who demonstreats the difficulty in decision making on the borderline between conventionell coronary bypass grafting and alternative methods of revascularization such as transmyocardial laser revascularization.
    Notes: Zusammenfassung Anhand dieses Falles werden die Schwierigkeiten verdeutlicht, bei sehr schlecht revaskularisierbarem Patienten die Entscheidung zwischen konventionell koronarer Bypassoperation und transmyokardialer Laserrevaskularisation zu treffen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Herz-, Thorax- und Gefässchirurgie 13 (1999), S. 185-191 
    ISSN: 0930-9225
    Keywords: Schlüsselwörter Perkutane Tracheotomie ; Translaryngeal ; Komplikationen ; Intensivmedizin ; Key words Percutaneous tracheostomy ; translaryngeal ; complications ; intensive care medicine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary In intensive care medicine, percutaneous tracheostomy is internationally recognized as a practicable and safe alternative to conventional surgical tracheostomy. This also holds true for Fantoni‘s translaryngeal technique (TLT). Nonetheless, there are a number of reports of technical problems in the performance of TLT, especially with regard to the retrograde passage of the guide wire and the rotation of the cannula. We modified TLT in that the guide wire was passed retrograde through the endotracheal tube under videobronchoscopic control. Also, prior to rotation of the tracheal cannula, its position was verified by laryngoscopy and corrected if necessary. Feasibility of these modifications were analyzed in terms of operating time and oxygenation of the patient. 25 patients underwent modified TLT on our cardiosurgical ICU. Operating time was 4.8±3.9 minutes on the average. This is more than 50% below reported operating times in previous studies. During the procedure, there were no significant changes in PaO2 or oxygenation index (PaO2/FiO2). Also, there were no technical problems or complications. Our modifications enhance the safety and practicability of TLT as compared to the original technique. Nonetheless, a definitive evaluation will have to await the publication of studies with a larger number of patients.
    Notes: Zusammenfassung Die perkutane Tracheotomie in der Intensivmedizin ist als eine praktikable und komplikationsarme Alternative zur konventionell-chirurgischen Tracheotomie weltweit anerkannt. Auch für das neue Verfahren der translaryngealen Technik nach Fantoni (TLT) konnten bislang ähnliche Ergebnisse gezeigt werden. Dennoch wurde mehrfach auf technische Probleme bei der Durchführung der TLT berichtet, die vor allem das retrograde Ausleiten des Führungsdrahtes sowie die Rotation der Kanüle betrafen. Die Technik der TLT wurde dahingehend modifiziert, daß der Draht unter videobronchoskopischer Sicht retrograd durch den Tubus ausgeleitet und vor der Trachealkanülenrotation die Kanülenlage unter laryngoskopischer Sicht kontrolliert und gegebenenfalls korrigiert wurde. Die Praktikabilität des Verfahrens wurde anhand der Operationszeiten bestimmt und der Einfluß auf die Oxygenierung der Patienten gemessen. Das Verfahren wurde bei 25 herzchirurgischen Intensivpatienten durchgeführt. Die OP-Zeiten betrugen im Mittel 4,8±3,9 Minuten und lagen damit mehr als 50% unter denen früherer Untersuchungen. PaO2 und Oxygenierungsindex (PaO2/FiiO2) veränderten sich während des Eingriffs nicht signifikant. Es wurden keinerlei Komplikationen, Infektionen oder technische Probleme beobachtet. Durch die Modifikation der Technik konnten Praktikabilität und Sicherheit der TLT gegenüber früheren Untersuchungen erhöht werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...