Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    HNO 48 (2000), S. 75-90 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter ; 3D-Navigation ; Rahmenlose Stereotaxie ; Computerunterstützte Chirurgie ; Intraoperative Navigation ; Key words ; 3D-navigation ; Frameless stereotaxy ; Computer aided surgery ; CAS ; Intraoperative navigation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary 3D-navigation systems have only recently been introduced into the surgical field. Since then they have gained increasing importance not only in ENT surgery but also in neurosurgery, orthopedic surgery, maxillo-facial surgery, radiology and radiotherapy. Following a brief historical introduction this article reviews existing navigation technologies, in terms of indication, practicability, accuracy, forensic and financial aspects. The selection of the navigation system is strongly influenced by the planned procedure (endoscopic, microscopic, open approach). According to our experience most of these systems provide useful support intraoperatively. The clinical application accuracy regularly lies in the range of 1–2 mm.
    Notes: Zusammenfassung Seit der Entwicklung und der kommerziellen Verfügbarkeit von intraoperativen 3D-Navigationssystemen hat diese Technologie nicht nur in der Hals-Nasen-Ohrenchirurgie sowie der Neurochirurgie, sondern auch anderen Disziplinen, wie Orthopädie, Kieferchirurgie, Strahlentherapie und Radiologie an Bedeutung gewonnen. Nach einem kurzen historischen Überblick werden unterschiedliche Navigationstechnologien in ihrer Arbeitsweise dargestellt und anhand von klinischen Anwendungen verdeutlicht. Die Auswahl des geeigneten Navigationssystems richtet sich nach der Art des geplanten Eingriffs (endoskopisch, mikroskopisch, kombiniert). Durch intensive Weiterentwicklung dieser Systeme leisten sie bereits heute eine wertvolle Unterstützung für den HNO-Chirurgen. Die derzeit erzielbare intraoperative Genauigkeit liegt für die meisten Systeme regelhaft bei 1–2 mm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Intraoperative Navigation ; Computerunterstützte Chirurgie ; Felsenbein ; Modellstudie ; ISG Viewing Wand ; Key words Intraoperative navigation ; Computer-assisted surgery ; Petrous bone ; Anatomic model ; ISG Viewing Wand
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Surgical interventions in the petrous bone have to be performed in close relationship to vital and delicate anatomical structures. In cases of revision surgery or with massive pathological changes 3D computer-assisted navigation provides an essential tool for preoperative planning, definition of target structures and intraoperative orientation. This technology can help to diminish intraoperative risks for the patient and may help to optimize any microsurgery. In this report we present our first experiences in using the ISG Viewing Wand in the petrous bone through a specially designed model. By recording more than 4000 single measurements we found that the ISG Viewing Wand can be used with sufficient precision. We have now outlined the most important conditions necessary for possible application to a patient.
    Notes: Zusammenfassung Chirurgische Eingriffe am Felsenbeim werden in engster Nachbarschaft von vitalen Strukturen durchgeführt. Bei Revisionsoperationen oder bei ausgedehnten pathologischen Veränderungen kann der Chirurg durch den Einsatz computerunterstützter intraoperativer 3D-Navigation zur Orientierung und Definition von Zugangswegen sowie Zielstrukturen, Operationsrisiken entscheidend verringern. Wir zeigen die Möglichkeiten und Grenzen eines Einsatzes der ISG Viewing Wand (ISG Technologies, Mississauga, Ontario, Kanada) für dieses neue Einsatzgebiet anhand von Genauigkeitsmessungen an einem Felsenbeinmodell auf. Die unter möglichst realistischen Bedingungen durchgeführten Messungen am Modell zeigen, daß die ISG Viewing Wand unter bestimmten Voraussetzungen bei Eingriffen am Felsenbein verwendet werden kann, so daß der Operateur eine zuverlässige intraoperative Navigation zur Verfügung hat. Wir präsentieren die Ergebnisse aus über 4000 Einzelmessungen und skizzieren einen möglichen Einsatz am Patienten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...