Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1440
    Keywords: Gated blood pool scintigraphy ; Coronary heart disease ; Ejection fraction ; Volume curves ; Funktionsszintigraphie des Herzens ; Koronare Herzerkrankung ; Auswurffraktion ; max. Volumenänderungsgeschwindigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 43 Patienten mit koronarer Herzerkrankung sowie 24 Patienten, bei denen eine Erkrankung des Herzens ausgeschlossen werden konnte, wurden nach i.v. Injektion von 15mCi99mTc-Humanserum-Albumin mittels eines Gamma-Kamera-Computersystems die Volumenänderungen im Verlauf einer „repräsentativen“ Herzaktion auf nichtinvasivem Wege registriert und quantitativ ausgewertet. Aus der so gewonnenen Volumenänderungskurve des linken Ventrikels wurden die Auswurffraktion sowie die maximale Füllungs- und Entleerungsgeschwindigkeit bestimmt. Bei Patienten mit koronarer Herzerkrankung kam es zu einer signifikanten, schweregradabhängigen Abnahme dieser Parameter, wobei die Veränderung der maximalen Füllungsgeschwindigkeit als Ausdruck einer Herabsetzung der Compliance besonders ausgeprägt war. Das Verfahren erscheint somit zur nichtinvasiven Beurteilung der Funktion des linken Ventrikels geeignet.
    Notes: Summary In 43 patients with angiographically proven coronary heart disease and in 24 patients without heart disease, gated blood pool scintigraphy was done under resting conditions with 15 mCi99mTcHSA in LAO projection. Scintigraphic data were collected in list mode by means of a gamma camera connected to a computer system (Siemens 330). A cumulative scintigram sequence with a time resolution of 100 frames/s was constructed using several hundred heart cycles of equal duration. After background correction volume curves of the left ventricle were obtained and the following parameters were calculated: EF,dV/dt max,dV/dt min. In all patients with coronary heart disease, these parameters were reduced depending on the severity of the stenotic lesion. The changes ofdV/dt min and to a greater extent ofdV/dt max were more pronounced than those of the EF. These results are in keeping with invasively obtained data which show that a decrease of myocardial compliance is one of the earliest manifestations of CHD. Quantitative gated nuclear cardiography allows, therefore, noninvasive evaluation of left ventricular function even under resting conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...