Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (9)
  • Cytoskeleton  (4)
  • Forensic identification  (2)
  • Submillimeter wave  (2)
Material
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/General Subjects 880 (1986), S. 197-203 
    ISSN: 0304-4165
    Keywords: (Human platelet) ; Cytoskeleton ; Mersalyl ; Myosin ; Sulfhydryl
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    FEBS Letters 206 (1986), S. 273-278 
    ISSN: 0014-5793
    Keywords: (Blood platelet) ; Ca^2^+ transient ; Cytoskeleton ; Myosin ; Phorbol ester ; Protein kinase C
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/General Subjects 801 (1984), S. 290-297 
    ISSN: 0304-4165
    Keywords: (Human) ; Calmodulin ; Cytoskeleton ; Platelet activation
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 110 (1997), S. 36-38 
    ISSN: 1437-1596
    Keywords: Key words CSF1PO ; STR polymorphism ; Forensic identification ; Degraded DNA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Abstract We describe new primers for the detection of the STR polymorphism at the CSF1PO locus. These primers have been designed to produce shorter amplicons (150– 182 bp) than the primers in standard use (295–327 bp). The reliability of the new primers for CSF1PO typing has been demonstrated by testing on known samples and by sequence analysis. These primers are superior to the original primers with regard to electrophoretic resolution and utility for typing of severely degraded DNA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 110 (1997), S. 36-38 
    ISSN: 1437-1596
    Keywords: CSF1PO ; STR polymorphism ; Forensic identification ; Degraded DNA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Abstract We describe new primers for the detection of the STR polymorphism at the CSF1PO locus. These primers have been designed to produce shorter amplicons (150–182 bp) than the primers in standard use (295–327 bp). The reliability of the new primers for CSF1PO typing has been demonstrated by testing on known samples and by sequence analysis. These primers are superior to the original primers with regard to electrophoretic resolution and utility for typing of severely degraded DNA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1615-6102
    Keywords: Boergesenia forbesii ; Cellulose synthesizing complex ; Cytoskeleton ; Helicoidal wall ; Membrane fluidity ; Microfibril orientation ; Plasma membrane
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary Microfibrillar textures and orientation of cellulose microfibrils (MFs) in the coenocytic green alga,Boergesenia forbesii, were investigated by fluorescence and electron microscopy. Newly formed aplanosporic spherical cells inBoergesenia start to form cellulose MFs on their surfaces after 2 h of culture at 25°C. Microfibrillar orientation becomes random, fountain-shaped, and helicoidal after 2, 4, and 5 h, respectively. The fountain orientation of MFs is usually apparent prior to helicoidal MF orientation and thus may be considered to initiate helicoid formation. Microfibrils continue to take on the helicoidal arrangement during the growth ofBoergesenia thallus. The helicoidal orientation of MFs occurs through gradual counterclockwise change in MF deposition by terminal complexes (TCs) viewed from inside the cell. On the dorsal side of curving TC impressions in helicoidal texture formation on a freeze-fractured plasma membrane, the aggregation of intramembranous particles (IMPs) occurs. Membrane flow may thus possibly affect the regulation of helicoidal orientation inBoergesenia. Following treatment with 3 μM amiprophos-methyl (APM) or 1 mM colchicine, cortical microtubules (MTs) completely disappear within 24 h but helicoidal textures formation is not affected. With 15 μM cytochalasin B or 30 μM phalloidin, however, the helicoidal orientation of MFs becomes random. Treatment with CaCl2 (10 mM) causes the helicoidal MF orientation of cells to become random, but co-treatment with N-(6-aminohexyl)-5-chloro-1-naphthalene sulfonamide (W-7) (100 mM) prevents this effect, though W-7 has no effect on the helicoidal MF formation. It thus follows that MF orientation inBoergesenia possibly involves actin whose action may be regulated by calmodulin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 19 (1998), S. 1303-1316 
    ISSN: 1572-9559
    Keywords: Gyrotron ; Misalignment ; Electron beam ; Submillimeter wave
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Electron beam misalignment in a submillimeter-wave gyrotron strongly affects its total efficiency as well as excitation of rotating and counterrotating modes. Some of misalignment phenomena were studied theoretically and experimentally.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 19 (1998), S. 919-930 
    ISSN: 1572-9559
    Keywords: Gyrotron ; Submillimeter wave ; High mode purity operation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The cavity of the newest gyrotron, Gyrotron FU IVA in the high frequency series of Fukui University gyrotrons (the Gyrotron FU series) is designed to minimize the mode conversion from the main cavity mode to the higher modes. In this paper, the experimental results are compared with simulations for the complete gyrotron oscillator. The gyrotron has an additional advantage to cover the wide frequency range in submillimeter wave region.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 2061-2074 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: As demonstrated in Part II of this series of studies, the hydrophobic character of CF4 plasma-treated Nylon 6 and poly(ethylene terephthalate) (PET) decay with time of water immersion, and the rate of decay can be used as a measure for the surface mobility of (substrate) polymers. The same method of using fluorine-containing moieties introduced by CF4 plasma treatment as surface labeling is applied to investigate the influence of a thin layer of plasma polymer of methane applied onto the surface of those polymers. An ultrathin layer of plasma polymer provides a barrier to the rotational and diffusional migration of the introduced chemical moieties from the surface into the bulk of the film. The influence of operational parameters of plasma polymerization on the surface dynamic stability are examined by measuring the decay rate constants for (subsequently) CF4 plasma-treated samples. The rate constant was found to decrease sharply with increasing value of plasma energy input manifested by J/kg monomer, and no decay was observed as the energy input reached a threshold value (about 6.5 GJ/kg for PET, about 7.0 GJ/kg for Nylon 6), indicating that unperturbable surfaces can be created by means of plasma polymerization.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 1781-1794 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Macromolecules at the surface of a polymeric solid have considerable mobility, and the specific arrangement of functional groups of macromolecules at the surface is dictated by the environmental conditions in which the surface is placed. Consequently, the change of environmental conditions, such as immersion in water or placement in a biological surrounding, could cause a cosiderable degree of change in the surface characteristics of a polymer from those evaluated in the laboratory against ambient air. The mobile nature of a polymer surface can be investigated by surface-implanting fluorine-containing moieties, mainly - CF3, by the plasma implantation technique and following the disappearance and reappearance of fluorine atoms on the surface. The disappearance rates (based on the immersion time in water at room temperature) of ESCA F1s signals, the decay rates of (advancing) contact angle of water, and the recovery of these values on heat treatment of water-immersed samples were measured as a function of crystallinity of polymer samples (at three levels of crystallinity) for poly(ethylene terephthalate) and nylon 6.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...