    Keywords: High-speed GC ; Electron capture detector (ECD) ; Detection limits ; PCBs ; Pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this work the combination of high-speed narrow-bore capillary GC with electron capture detection is evaluated. The make-up gas flow rate is a key parameter in the successful coupling of narrowbore columns and ECD detection. The make-up flow has to be as high as possible to eliminate peak tailing caused by the large detection cell volume. The sensitivities at these elevated make-up flow rates (400 to 1000 ml/min), measured for some pesticides like HCB and dieldrin, were very good. Detection limits for these compounds of 0.1 pg were obtained, resulting in minimum detectable concentrations of approximately 0.2 ppb. The performance of the system is illustrated by several high-speed analyses of environmentally relevant samples of PCBs and pesticides.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 491-497 
    ISSN: 0935-6304
    Keywords: Fast GC ; narrow-bore columns ; trace analysis ; splitless injection ; on-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The use of hot splitless, cold splitless, and on-column injections for trace analysis in narrow-bore capillary GC is evaluated. Despite the low flow rates for the columns used, the required splitless times for splitless injections can be surprisingly short if liners with a small inside diameter are used. On-column injection can be applied by using an appropriate normal-bore precolumn coupled to the narrow-bore analytical column using a specially designed low dead volume column connector. The effects of the experimental conditions such as sample volume, injection temperature, and initial oven temperature on peak focusing and the discrimination and degradation behavior of the analytes are discussed. The possibilities to obtain sensitive and fast separations are illustrated by various applications.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 509-513 
    ISSN: 0935-6304
    Keywords: Fast GC ; fast temperature programming ; resistive heating techniques ; short columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---One possible way to speed up a gas chromatographic analysis is the application of fast temperature programming by using resistive heating techniques. With this heating technique programming rates up to 20° per second can be reached. A relative standard deviation of retention times better than 0.2% is obtained. Using fast temperature programming the analysis-times of a mineral oil sample, an industrial oligomer sample, and toxic compounds in diesel fuel have been reduced 5 to 20 times, compared to a standard temperature programmed analysis. In most cases resistive heating cannot be applied to reduce the analysis time of a complex sample. The use of fast temperature programming is preferable to the use of short columns and columns operated at above-optimum carrier gas velocities.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 517-524 
    ISSN: 0935-6304
    Keywords: GC/MS ; Scan speed ; Detection limits ; High-speed GC ; Narrow-bore columns ; High-resolution MS ; Sector mass spectrometers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this work the application of high-speed narrow-bore capillary GC in combination with a fast scanning double focusing magnetic sector mass spectrometer is evaluated. Special emphasis is placed upon detection limits and scan speed in the full scan mode and in the selected ion monitoring mode (SIM). In the full scan mode, up to 20 scans per second could be obtained. The detection limits are in the low picogram range in the full scan mode and improve even to 5 to 50 fg in the SIM mode, depending on the sample complexity and mass resolving power. It will be illustrated that by increasing the resolution in the SIM mode, interferences from ions of the same nominal mass-to-charge ratio as the ions of interest are significantly reduced. Chemical background noise can therefore be largely eliminated, thus enhancing the signal-to-noise ratio.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...