Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Solid-phase extraction ; Gas chromatography ; Ion trap tandem mass spectrometry ; Water samples ; Environmental analysis ; Pesticides ; Bromide ; Nitrite
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On-line solid-phase extraction-gas chromatographyion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90°C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1–500 ng L−1, using a sample volume of 10–100 mL for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01–4 ng L−1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L−1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L−1, respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Atomic emission and MS detection ; Solid-phase extraction ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC systems to enable the determination of microcontaminants at the 0.02–1 μg L−1 level in 7–50 mL of aqueous sample. The screening was limited to compounds present in at least one heteroatom-selective GC-AED trace above a predetermined concentration level. These compounds were identified by their partial formulae (AED) and the corresponding mass spectra, which were obtained from the GC-MS chromatogram via the retention index concept. The potential of the approach was demonstrated by the identification of target compounds as well as all unknowns present in tap and waste water above the predetermined threshold of 0.05 μg L−1 (tap water) or 0.5 μg L−1 (waste water).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...