Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • HPLC chiral stationary phase  (2)
  • chiral separation  (2)
  • protein binding  (2)
  • 1
    ISSN: 1573-904X
    Keywords: chiral stationary phases ; human serum albumin ; protein binding ; binding sites ; high-performance liquid chromatography ; immobilized proteins ; chemical modification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The in situ modification of an immobilized human serum albumin (HSA) high-performance liquid chromatographic chiral stationary phase by p-nitrophenyl acetate is reported. This procedure, which is thought to affect primarily a single reactive tyrosine residue within the protein structure, influenced the chromatographic retention and enantioselectivity factors of a wide range of solutes. For certain solutes, increases in both capacity factor and chiral resolution were observed. Ultrafiltration studies on representative test solutes using free HSA, treated in a similar manner to the immobilized protein, gave similar results as the chromatographic observations, indicating that the latter effects are not artifactual results of immobilization. The effect of the modification of HSA on the binding behavior of drugs reportedly sharing the site predominantly affected by the derivatization, namely, the indole–benzodiazepine binding site, varied greatly. This observation suggests that the affected binding area is not a single, tightly structurally defined site.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-904X
    Keywords: propanolol enantiomers ; enantioselective high-performance liquid chromatography (HPLC) ; HPLC chiral stationary phase ; serum levels
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A commercially available high-performance liquid chromatographic (HPLC) chiral stationary phase (HPLC-CSP) has been used to measure serum levels of d- and l-propranolol. The HPLC-CSP is based upon cellulose–tris(3,5-dimethylcarbamate) and is able to stereochemically resolve d- and l-propranolol without precolumn derivatization using a mobile phase composed of hexane:2-propranol:N,N-dimethyloctylamine (92:8:0.01, v/v/v). Under these conditions the observed stereochemical resolution (α) of the two enantiomers was α = 2.2. A subject's concentration–time curve of the two isomers was determined following the ingestion of 160 mg racemic propranolol.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0899-0042
    Keywords: gas chromatography ; modified β-cyclodextrin column ; chiral separation ; assay ; mexiletine ; hydroxylated metabolites ; urine ; conjugation/deconjugation ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The enantiomers of mexiletine and four of its hydroxylated metabolites were directly separated by capillary gas chromatography using a heptakis(6-O-tert-butyl-dimethylsilyl-2,3-di-O-methyl)-β-cyclodextrin column. The method was applied to the analysis of urine samples from cancer patients who were treated with racemic mexiletine as part of a study of the use of mexiletine in the relief of neuropathic pain. Samples analyzed before and after deconjugation of the urine with β-glucuronidase/arylsulfatase showed a high stereoselectivity in the formation and conjugation of these compounds. © 1996 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0899-0042
    Keywords: protein binding ; stereoselectivity ; immobilized human serum albumin ; HPLC chiral stationary phase ; chiral drugs ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A human serum albumin-based HPLC chiral stationary phase (HSA-CSP) has been examined as a tool to investigate binding of chiral drugs to HSA and drug-drug protein-binding interactions. Rac-oxazepam hemisuccinate (OXH) was used as a model compound and the chromatographic retention (k′) of its enantiomers was determined after addition of displacers to the mobile phase. Compounds known to bind at the same site as OXH and at different sites were tested for their displacing capacities. Competitive binding interactions between the OXH enantiomers and displacers in the mobile phase were reflected by decreases in the k′s of (R)- and (S)-OXH. The results indicate that retention on the HSA-CSP accurately reflects binding to native HSA and the technique can determine enantioselective and competitive binding interactions at specific sites on HSA. The HSA-CSP was also able to recognize separate binding areas for (S)- and (R)-OXH.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0899-0042
    Keywords: salbutamol ; chiral separation ; validated assay ; fluorescence detection ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sensitive enantioselective high-performance chromatographic (HPLC) method was developed and validated to determine low levels of (-)-R and (+)-S-albuterol in plasma. Baseline resolution was achieved by using a teicoplanin-based chiral stationary phase with a polar organic mobile phase consisting of methanol/acetonitrile/glacial acetic acid/diethylamine, 40:60:0.3:0.2, (v/v/v/v) and a flow-rate of 1.0 ml/min. Enantioselectivity (α) equaled 1.18 and resolution (Rs) equaled 1.8. By using fluorescence detection maximized at 230 and 310 nm for excitation and emission, respectively, concentrations of each enantiomer could be measured down to 125 pg/ml from a 1-ml plasma sample. Initially, the method was applied to plasma samples from a small single-dose inhalation study of racemic albuterol in a human volunteer and, later, to in vivo samples from a canine inhalation study of the single enantiomer, (-)-R-albuterol. Results from the canine study showed that no chiral inversion of (-)-R-albuterol occurs in the dog. Chirality 10:484-491, 1998. © 1998 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗