Summary The absolute oral bioavailability of pindolol has been estimated by two analytical methods, fluorimetry and GLC-ECD. The study was carried out in six healthy subjects who received either i.v. or oral pindolol in random order. The results obtained by both methods were similar and confirm the high bioavailability (about 75%) of pindolol. The present findings are compared with previous publications and emphasize the importance of undertaking bioavailability studies in the same subjects.