Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Insulin antibodies  (1)
  • Insulin receptor binding  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of molecular medicine 63 (1985), S. 545-553 
    ISSN: 1432-1440
    Schlagwort(e): Type I diabetes ; Insulin resistance ; Euglycaemic clamp ; Insulin receptor binding ; Insulin antibodies
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Insulin sensitivity was assessed using the euglycaemic clamp technique in eight type I diabetic patients (after overnight blood glucose normalization with an artificial pancreas) and in six healthy subjects. Basal insulin concentrations were higher in diabetic patients (25±4 µU/ml) than in control subjects (17±1 µU/ml;P〈0.05). Insulin infusion of 0.5, 1.0, 2.0 and 5.0 mU/kg per min during subsequent 2-h periods resulted in similar mean steady-state insulin concentrations in both groups. The mean dextrose requirements during the last 40 min of each period were nevertheless decreased in diabetic patients (1.6±0.5, 3.5±0.8, 6.5±0.7, 10.2±0.7 mg/kg per min) as compared with control subjects (4.7±0.3, 8.2±0.9, 10.2±0.9, 12.4±0.9 mg/kg per min). At low insulin concentrations dextrose requirements were diminished in all diabetic subjects. At the highest insulin levels, individual dose-response curves from only four patients were within the normal range. Under basal conditions, the monocyte receptor number was significantly reduced in diabetic patients (17,500±2,800 sites/cell) as compared with control subjects (26,700±2,500 sites/cell;P〈0.05), whereas there were no differences regarding empty site affinities. Receptor data did not differ in patients with normal and decreased maximal dextrose requirements. Insulin resistance is apparently a common feature of type I diabetes at serum insulin concentrations of approximately 100 µU/ml. Normalization of the insulin effect by higher insulin concentrations is not possible in all patients. Insulin antibodies at concentrations observed in this study (〈0.16 mU/ml) do not contribute significantly to insulin resistance; receptor and postreceptor defects are possibly more important.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...