  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 63 (1985), S. 545-553 
    ISSN: 1432-1440
    Keywords: Type I diabetes ; Insulin resistance ; Euglycaemic clamp ; Insulin receptor binding ; Insulin antibodies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Insulin sensitivity was assessed using the euglycaemic clamp technique in eight type I diabetic patients (after overnight blood glucose normalization with an artificial pancreas) and in six healthy subjects. Basal insulin concentrations were higher in diabetic patients (25±4 µU/ml) than in control subjects (17±1 µU/ml;P〈0.05). Insulin infusion of 0.5, 1.0, 2.0 and 5.0 mU/kg per min during subsequent 2-h periods resulted in similar mean steady-state insulin concentrations in both groups. The mean dextrose requirements during the last 40 min of each period were nevertheless decreased in diabetic patients (1.6±0.5, 3.5±0.8, 6.5±0.7, 10.2±0.7 mg/kg per min) as compared with control subjects (4.7±0.3, 8.2±0.9, 10.2±0.9, 12.4±0.9 mg/kg per min). At low insulin concentrations dextrose requirements were diminished in all diabetic subjects. At the highest insulin levels, individual dose-response curves from only four patients were within the normal range. Under basal conditions, the monocyte receptor number was significantly reduced in diabetic patients (17,500±2,800 sites/cell) as compared with control subjects (26,700±2,500 sites/cell;P〈0.05), whereas there were no differences regarding empty site affinities. Receptor data did not differ in patients with normal and decreased maximal dextrose requirements. Insulin resistance is apparently a common feature of type I diabetes at serum insulin concentrations of approximately 100 µU/ml. Normalization of the insulin effect by higher insulin concentrations is not possible in all patients. Insulin antibodies at concentrations observed in this study (〈0.16 mU/ml) do not contribute significantly to insulin resistance; receptor and postreceptor defects are possibly more important.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...