Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Internal standard  (1)
  • Lorentz-Lorenz relation  (1)
  • Selenium  (1)
  • 1
    ISSN: 1438-2385
    Keywords: Key words Polymerase chain reaction ; Campylobacter ; Internal standard ; Food ; False negatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract  A heterologous internal standard, termed "mimic", was developed for the polymerase chain reaction (PCR)-based detection of Campylobacter jejuni and Campylobacter coli in food. Mimic was designed to contain a heterologous DNA fragment of plasmid pUC18, flanked by a primer binding site, identical to the bacterial target DNA. Application of mimic in the PCR permitted its co-amplification together with the bacterial DNA with similar efficiency. As the length of the amplified products differed, they were easily detectable by agarose gel electrophoresis. The presence or absence of the mimic PCR product was indicative of the efficacy of the PCR. The use of approximately 60 mimic molecules per reaction was optimal for determining the reliability of the diagnostic PCR assays without decreasing the detection limit. This system for the detection of the two species of Campylobacter was successfully applied in routine food surveillance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 17 (1991), S. 40-44 
    ISSN: 1432-1238
    Keywords: Septic shock ; Lipid peroxidation ; Alphatocopherol ; Selenium ; Oxygen free radicals ; Outcome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In order to assess if an oxidant/antioxidant imaalance is involved in human septic shock and its outcome, we measured plasma levels of the lipid peroxides malondialdehyde—as thiobarbituric acid reactive substance—conjugated dienes and fluorescent products, together with the antioxidants alpha-tocopherol, glutathione peroxidase activity and selenium in 12 patients with septic shock and compared them with values of normal controls. At first measurements, malondialdehyde (median 3.9 μmol/l; range 2–38.8) and fluorescent products (median 21.2%; range 9.4–134) were elevated (p〈0.05), alpha-tocopherol (median 15 μmol/l; range 7–25) and selenium (median 0.76 μg/ml; range 0.49–1.09) were depressed (p〈0.05). Conjugated dienes and glutathione peroxidase activity were in the normal range. In non-survivors (n=5) initial levels of malondialdehyde and fluorescent products (median 11 versus 3.1 μmol/l; 74 versus 135 respectively) were higher than in survivors (p〈0.05) and initial selenium levels were lower (median 0.58 versus 0.92 μg/l;p〈0.05). These results are consistent with the concept that an oxidant/antioxidant imbalance—as indicated by elevated plasma lipid peroxides and depressed antioxidants—is involved in human septic shock and a fatal outcome.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 7 (1986), S. 41-51 
    ISSN: 1572-9567
    Keywords: capillary coefficient ; coexistence curve ; Lorentz-Lorenz relation ; mixtures ; refractive index ; surface tension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The objective of this paper is to present measurements of the vapor pressure, capillary coefficient, and refractive index of four binary mixtures, CO2-SF6, R14-SF6, SF6-R13B1, and SF6-R22, at liquid-vapor equilibrium at different average concentrations. The measuring temperature range covered the entire liquid-vapor region from the triple line up to the critical point. The capillary coefficient was determined by means of the capillary rise method; the refractive index, by measuring the angle of refraction of a light beam passing through a prism and the sample. In order to obtain the liquid-vapor densities of pure substances the Lorentz-Lorenz relation can be used. However, in applying this relation to calculate the liquid-vapor densities of a mixture, one may need the concentrations of both the liquid and the vapor phase, which are, for the most part, quite different from the average concentration of the mixture. Calculating the concentrations of both fluid phases with the aid of an equation of state and comparing with measurements, we could show that the molar refraction coefficient of the mixtures can be simply determined from the average concentration and the molar refraction coefficients of their pure components. The surface tension of the mixtures could then be calculated from the measured capillary coefficient and the refractive index with the aid of the Lorentz-Lorenz relation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...