Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    HNO 48 (2000), S. 75-90 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter ; 3D-Navigation ; Rahmenlose Stereotaxie ; Computerunterstützte Chirurgie ; Intraoperative Navigation ; Key words ; 3D-navigation ; Frameless stereotaxy ; Computer aided surgery ; CAS ; Intraoperative navigation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary 3D-navigation systems have only recently been introduced into the surgical field. Since then they have gained increasing importance not only in ENT surgery but also in neurosurgery, orthopedic surgery, maxillo-facial surgery, radiology and radiotherapy. Following a brief historical introduction this article reviews existing navigation technologies, in terms of indication, practicability, accuracy, forensic and financial aspects. The selection of the navigation system is strongly influenced by the planned procedure (endoscopic, microscopic, open approach). According to our experience most of these systems provide useful support intraoperatively. The clinical application accuracy regularly lies in the range of 1–2 mm.
    Notes: Zusammenfassung Seit der Entwicklung und der kommerziellen Verfügbarkeit von intraoperativen 3D-Navigationssystemen hat diese Technologie nicht nur in der Hals-Nasen-Ohrenchirurgie sowie der Neurochirurgie, sondern auch anderen Disziplinen, wie Orthopädie, Kieferchirurgie, Strahlentherapie und Radiologie an Bedeutung gewonnen. Nach einem kurzen historischen Überblick werden unterschiedliche Navigationstechnologien in ihrer Arbeitsweise dargestellt und anhand von klinischen Anwendungen verdeutlicht. Die Auswahl des geeigneten Navigationssystems richtet sich nach der Art des geplanten Eingriffs (endoskopisch, mikroskopisch, kombiniert). Durch intensive Weiterentwicklung dieser Systeme leisten sie bereits heute eine wertvolle Unterstützung für den HNO-Chirurgen. Die derzeit erzielbare intraoperative Genauigkeit liegt für die meisten Systeme regelhaft bei 1–2 mm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0458
    Keywords: Schlüssselwörter Eismann ; Computerunterstützte Chirurgie ; CAS-Intraoperative Navigation ; Schleimhautbiopsien ; Key words Prehistoric Iceman ; Computer assisted surgery ; Intraoperative navigation ; Mucosal biopsies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The University of Innsbruck possesses a unique prehistoric, completely conserved 5300-year-old human cadaver. We report our experiences during which ENT specialists collected samples from various cavities inside the Iceman. Guidance of biopsy instruments was accomplished with computer-assisted navigation based on Interventional Video Tomography. This technology allows surgical guidance by interlinking currently available imaging modalities with live endoscopic video. The system operates without patient fixation and is practically free of external contact. Apart from sterility, special precautionary measures were necessary to avoid contamination with heavy metals or microorganisms. Visual inspection of the samples of mucosa from the nose, maxillary sinus and larynx revealed the typical patterns of a human cadaver without overt pathology.
    Notes: Zusammenfassung Die Universität Innsbruck bewahrt einen einzigartigen prähistorischen Fund: eine vollständige, erstaunlich gut erhaltene 5300 Jahre alte Gletscherleiche. Wir berichten über die Gewinnung menschlicher archäologischer Gewebeproben unter Verwendung modernster minimal-invasiver computerunterstützter 3D-Navigationstechniken. Neben Erfüllung der üblichen hygienischen Standards mußte in diesem Spezialfall eine Kontamination des Eismannes mit Schwermetallen, Partikeln, oder Teilen von Mikroorganismen vermieden werden. In dem Eingriff wurden Proben aus der Nasenschleimhaut, der Kieferhöhle und dem Larynx gewonnen. Eine klinische Beurteilung durch den Operateur zeigte – trotz ihres Alters – eine typische, gesunde humane Kadaverschleimhaut.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...