    Intensive care medicine 26 (2000), S. 84-87 
    ISSN: 1432-1238
    Schlagwort(e): Key words High-frequency ventilation ; Noise production ; Newborn ; Neonatal intensive care unit ; Decibel
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: To test the hypothesis that neonatal high-frequency ventilators create different noise levels depending upon ventilator settings and device-specific properties.¶Materials: Three neonatal ventilators with built-in high-frequency options (Babylog 8000, Infant Star, Stephanie) and an exclusive high-frequency oscillator (SensorMedics 3100A).¶Measurements: Noise levels were recorded by a microphone and measured by a decibel recording device at a defined distance from a test lung.¶Results: Noise levels were highest for the SensorMedics and the Babylog (70 dB and 62 dB, respectively). Whereas the SensorMedics increased noise production with amplitude, the Babylog remained at a constant level. The Infant Star (52 dB) and the Stephanie (54 dB) were significantly less noisy at their maximum levels of amplitude (40 mbar and 50 mbar, respectively).¶Conclusion: Most levels recorded were below those measured within an incubator without the use of a ventilator. We conclude that neonatal high-frequency ventilators do not represent a major contribution to noise levels for newborns in neonatal intensive care units (NICUs).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1076
    Schlagwort(e): Key words Inhaled nitric oxide ; Intrapulmonary shunt ; Rabbit ; Surfactant deficiency ; Meconium
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Marked hypoxia secondary to intrapulmonary right-to-left shunting is a characteristic of respiratory failure in human neonates and can sometimes be complicated by additional extrapulmonary right-to-left shunting. To investigate the effect of inhaled nitric oxide (iNO) on intrapulmonary shunting, two typical pulmonary diseases of the newborn (respiratory distress syndrome and meconium aspiration) were reproduced in 32 mechanically ventilated rabbits weighing approximately 2 kg each. After tracheotomy, catheters were inserted into a jugular vein, a carotid artery and the right ventricle (to measure systolic right ventricular pressure [SRVP] and mixed venous oxygen content for calculation of shunt by Fick equation). Repeated airway lavages (LAV) with normal saline or repeated instillations of a suspension of human meconium (MEC) were continued until both the a/A-ratio was ≤0.14 and a peak inspiratory pressure ≥22 mbar was needed to keep the tidal volume constant at 10 ml/kg of body weight. Measurements of shunt, SRVP, systolic systemic pressure, physiological dead space, tidal volume and a ventilation index were performed before and after completion of lung damage and at 20 and 60 min after administering iNO at 80 ppm. Four groups of rabbits were studied (n = 8 in each group): LAV control and intervention, Mec control and intervention. 60 min after starting iNO, there was a decrease in shunt (LAV: 67.6% ± [SD] 11.3% vs 56.2 ± 16.4, P = 0.05; MEC: 52.6 ± 6.3 vs 44.3 ± 8.3, P 〈 0.05), in SRVP (LAV: 29.7 mmHg ± 10.1 mmHg vs 20.0 ± 8.2, P 〈 0.01; MEC: 25.1 ± 4.4 vs 22.3 ± 5.0, P = 0.46) and in dead space (% of tidal volume, LAV: 32.7% ± 10.5% vs 25.9 ± 10.1, P 〈 0.01; MEC: 26.1 ± 16.6 vs 18.9 ± 10.1, P = 0.05). These results demonstrate that iNO decreases intrapulmonary shunt (as well as SRVP and dead space). We suggest that iNO may be beneficial in human newborns with severe respiratory failure even if no extrapulmonary shunting via ductus or foramen ovale is apparent.
    Materialart: Digitale Medien