Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Lunge ; Mehrschicht-Spiral-CT ; MPR ; MIP ; Key words Lung ; Multisclice spiral-CT ; MPR ; MIP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: To test, whether axial, coronal and sagittal MIP and MPR reconstructions of diagnostic quality can be obtained from 1-mm collimation MSCT data of the chest for the evaluation of thoracic anatomy and pathology. Materials and Methods: 1-mm collimation MSCT scans were obtained with a pitch of 6 in an acrylic phantom and in 20 patients. Axial images were reconstructed with 0.6-mm increment. Multiplanar Reformations (MPRs) and Sliding Thin-Slab Maximum Intensity Projections (STS-MIPs) were reconstructed in axial, coronal and sagittal planes. Images were printed in lung windows and evaluated by three readers by using a standardized evaluation scheme. Results: Overall, both methods allowed good visualization of anatomic structures. MIP was superior for visualization of the pulmonary arteries (p 〈 0.05) while central and peripheral bronchi and the lung parenchyma were better depicted on multiplanar reconstructions. A confident diagnosis of thoracic pathology was feasible using both modalities, however MIPs appeared less usefull for evaluation of gross parenchymal abnormalities, such as pneumonic infiltrates or fibrotic changes. No significant difference in the degree of motion artifacts were detected between both modalities. Conclusion: MSCT data sets are ideally suited for generating MPR and MIP reconstructions. While MIPs are superior for the evaluation of thoracic vessels, MPR is advantageous for visualizing central and peripheral bronchi and the pulmonary parenchyma.
    Notes: Zusammenfassung Untersucht wurde die Darstellung der normalen und pathologischen Strukturen des Thorax mit der MPR- und MIP-Technik in drei Raumrichtungen berechnet aus einem 1 mm Spiraldatensatz des Mehrzeilen-Spiral-CT. Ein Plexiglasphantom und 20 Patienten wurden im Mehrzeilen-Spiral-CT mit 1 mm Schichtdicke und einem Pitch 6 untersucht. Die mit 0,6 mm Inkrement errechneten Bilddaten wurden mit der Multiplanaren Reformation (MPR) und der Sliding Thin-Slab Maximum Intensity Projection (STS-MIP) in axialer, koronarer und sagittaler Schichtführung reformatiert, im Lungenfenster ausgespielt und von drei Untersuchern nach festgelegten Kriterien ausgewertet. Beide Methoden boten eine gute Darstellung der anatomischen Strukturen. Die MIP-Technik war überlegen für die Darstellung der Lungengefäße ( p 〈 0,05), während in der MPR die zentralen und peripheren Atemwege sowie das Lungenparenchym besser dargestellt werden konnten. Die vorhandenen Pathologien waren mit beiden Verfahren diagnostizierbar, wobei die MIP-Berechnung für die Beurteilbarkeit von flächenhaften, hyperdensen Läsionen, z.B. Pneumonie oder ausgedehnte Fibrose weniger gut geeignet war. Hinsichtlich der Artefaktanfälligkeit fanden sich keine Unterschiede. Die Mehrschicht-Spiral-CT bietet optimale Voraussetzungen für die Rekonstruktion von MPR- und MIP-Datensätzen. Während die MIP für die Beurteilung der Gefäße vorteilhaft ist, ist die MPR für die Darstellung der zentralen und peripheren Atemwege und des Lungenparenchym besser geeignet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Lunge ; Mehrschicht-CT ; Spiral-CT ; Hochauflösende CT ; Lungenembolie ; Key words Lung ; Multislice CT ; Computed tomography ; Spiral-CT ; Thin-section CT ; Pulmonary embolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary With Multislice Spiral Computed Tomography (MSCT), existing indications for performing CT of the chest are strengthened and new applications are emerging. The high speed of MSCT improves efficiency, image quality and patient comfort of ”routine”- imaging of the chest. The ability to cover large volumes with thin slices improves the evaluation of mediastinal lymph nodes and pulmonary nodules and allows for high-quality secondary reconstruction. If a comprehensive diagnosis of the mediastinal structures and the pulmonary parenchyma is desired, MSCT for the first time allows reconstruction of contiguous and high- resolution (HRCT) sections from the same set of thin-collimation raw data. This way, contiguous chest images of superior and HRCT sections of equal image quality compared to conventional CT scanning can be obtained. Vascular protocols greatly benefit from the high speed of MSCT: For imaging the thoracic aorta or pulmonary emboli (PE), the amount of contrast material can be substantially reduced. Owing to thin collimation, the detection-rate of small peripheral emboli can be significantly increased. If indicated, the entire subphrenic venous system can be evaluated during the same session, without additional contrast material.
    Notes: Zusammenfassung Mit der Einführung der Mehrschicht-Spiral-CT (MSCT) werden die bestehenden Indikationen für die CT des Thorax bestätigt und neue Indikationen lassen sich erschließen. Die „Routine”-Bildgebung im Thorax ist mit der MSCT in gewohnter Weise möglich, wobei die hohe Scan-Geschwindigkeit die Effizienz der Untersuchung, die Bildqualität und den Patientenkomfort erhöht. Die Möglichkeit, auch große Organvolumina mit dünner Schichtung zu erfassen verbessert die Beurteilung von mediastinalen Lymphknoten und Lungenrundherden und ermöglicht qualitativ hochwertige dreidimensionale Rekonstruktionen. Soll eine umfassende Diagnose der Weichteilstrukturen und des Lungenparenchyms erfolgen, so ist es mit der MSCT erstmals möglich, aus einem einzigen, dünn kollimierten Spiral-Rohdatensatz sowohl kontinuierliche, als auch hochauflösende CT (HRCT) Schichten zu berechnen. Gegenüber der einzeiligen Spiral-CT ergibt sich dabei eine signifikant verbesserte Organabbildung in den kontinuierlichen Schichten und eine vergleichbare Bildqualität der HRCT. Die hohe Geschwindigkeit der MSCT ist von besonderer Bedeutung bei der Gefäßdarstellung im Thorax: Bei der Bildgebung der thorakalen Aorta und bei der Diagnostik der Lungenembolie (LE) kann die Kontrastmittel-Menge erheblich reduziert werden. Durch die dünne Schichtführung läßt sich der Nachweis segmentaler und subsegmentaler Embolien signifikant verbessern. Bei akuter LE kann das gesamte Venensystem der unteren Extremität ohne zusätzliche Kontrast- mittel in der gleichen Sitzung untersucht werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...