Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of earth sciences 85 (1996), S. 293-302 
    ISSN: 1437-3262
    Keywords: Iran ; palaeomagnetism ; Triassic ; Cretaceous ; Central Iran ; geotectonics ; palaeoreconstruction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Notes: Abstract New pole positions for Triassic and Cretaceous times have been obtained from volcanic and sedimentary sequences in Central Iran. These new results confirm the general trend of the Apparent Polar Wander Path (APWP) of the Central-East-Iran microplate (CEIM) from the Triassic through the Tertiary as published by Soffel and Förster (1983, 1984). Two new palaeopoles for the Triassic of the CEIM have been obtained; limestones and tuffs from the Nakhlak region yield a mean direction of 094.0°/25.0°, N=12, k=4.1,α 95=24.7°, after bedding correction, corresponding to a palaeopole position of 310.8°E; 3.9°S, and volcanic rocks from the Sirjan regions yield a mean direction of 114.5°/35.1°, N=44, k=45.9,α 95=3.2° after bedding correction and a palaeopole position of 295.8°E; 10.3°N. Combining these with the two previously published results yields a new palaeopole position of 317.5°E; 12.7°N, for the Triassic of the CEIM, thus confirming that large counterclockwise rotations of the CEIM have occurred since the Triassic time. New results have also been obtained from Cretaceous limestones from the Saghand region of the CEIM. The mean direction of 340.7°/26.3°, N=33, k=44.3,α 95=3.8°, and the corresponding palaeopole position of 283.1°E; 64.4°N, is in agreement with previously determined Cretaceous palaeopole positions of the CEIM. Furthermore, results have also been obtained from Triassic dolomite, limestone, sandstone and siltstone from the Natanz region, which is located to the west of the CEIM. A total of 161 specimens from 44 cores taken at five sites gave a mean direction of the five sites at 033.3°/25.1°, N=5, k=69.0,α 95=9.3° and a palaeopole position of 167.2°E; 53.7°N. They pass the positive fold test of McElhinny (1964) on the level of 99% confidence. This pole position is in fairly good agreement with the mean Triassic pole position of the Turan Plate (149°E; 49°N). It indicates that the area of Natanz has not undergone the large counterclockwise rotation relative to the Turan plate since the Triassic, which has been shown for the CEIM. A Triassic palaeogeographic reconstruction of Iran, Arabia (Gondwana) and the Turan Plate (Eurasia) is also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Geologische Rundschau 85 (1996), S. 293-302 
    ISSN: 0016-7835
    Keywords: Key words Iran ; palaeomagnetism ; Triassic ; Cretaceous ; Central Iran ; geotectonics ; palaeoreconstruction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Notes: Abstract  New pole positions for Triassic and Cretaceous times have been obtained from volcanic and sedimentary sequences in Central Iran. These new results confirm the general trend of the Apparent Polar Wander Path (APWP) of the Central-East-Iran microplate (CEIM) from the Triassic through the Tertiary as published by Soffel and Förster (1983, 1984). Two new palaeopoles for the Triassic of the CEIM have been obtained; limestones and tuffs from the Nakhlak region yield a mean direction of 094.0°/25.0°, N=12, k=4.1, α95=24.7°, after bedding correction, corresponding to a palaeopole position of 310.8°E; 3.9°S, and volcanic rocks from the Sirjan regions yield a mean direction of 114.5°/35.1°, N=44, k=45.9, α95=3.2° after bedding correction and a palaeopole position of 295.8°E; 10.3°N. Combining these with the two previously published results yields a new palaeopole position of 317.5°E; 12.7°N, for the Triassic of the CEIM, thus confirming that large counterclockwise rotations of the CEIM have occurred since the Triassic time. New results have also been obtained from Cretaceous limestones from the Saghand region of the CEIM. The mean direction of 340.7°/26.3°, N=33, k=44.3, α95=3.8°, and the corresponding palaeopole position of 283.1°E; 64.4°N, is in agreement with previously determined Cretaceous palaeopole positions of the CEIM. Furthermore, results have also been obtained from Triassic dolomite, limestone, sandstone and siltstone from the Natanz region, which is located to the west of the CEIM. A total of 161 specimens from 44 cores taken at five sites gave a mean direction of the five sites at 033.3°/25.1°, N= 5, k=69.0, α95=9.3° and a palaeopole position of 167.2°E; 53.7°N. They pass the positive fold test of McElhinny (1964) on the level of 99% confidence. This pole position is in fairly good agreement with the mean Triassic pole position of the Turan Plate (149°E; 49°N). It indicates that the area of Natanz has not undergone the large counterclockwise rotation relative to the Turan plate since the Triassic, which has been shown for the CEIM. A Triassic palaeogeographic reconstruction of Iran, Arabia (Gondwana) and the Turan Plate (Eurasia) is also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 245 (1988), S. 136-141 
    ISSN: 1434-4726
    Keywords: Tympanic membrane structure ; Topical anesthetics ; Emla ; Rat ; Guinea pig
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A eutectic mixture of two anesthetic solutions is that of lidocaine and prilocaine, which is available commercially as Emla (eutectic mixture of local anesthetics). This solution is commonly used in clinics in superficial skin surgery and when inserting intravenous catheters, and we also wanted to determine its surface effects when applied onto the tympanic membranes (TM) of rats and guinea pigs as animal models. The animals were observed by otomicroscopy for 2 weeks up to 5 months after administrations of the anesthetic solution. Tissue specimens were then obtained for light microscopy and fine structural analysis. The application of Emla caused minor structural changes to the rat TM, but hardly any alterations to that of the guinea pig. The changes displayed were an overall increased thickness, with typical submucosal edema but only slight epithelial reaction. In comparison with previous results with lidocaine, phenol and Bonain's solution, Emla seemed to be harmless to the structure of the TM. However, the efficacy of Emla as a topical TM anesthetic remains to be proved in future clinical trials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 249 (1993), S. 470-472 
    ISSN: 1434-4726
    Keywords: Otitis media ; Tympanic membrane ; Topical phenol anesthesia ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In the present study, local anesthetics were applied to the tympanic membrane (TM) of rats following experimentally evoked purulent otitis media (POM). The structure of the TM was evaluated 24 h, 2 weeks and 3 months after application of phenol to a discrete are of the right TM. The left ear was used as a control. POM induced swelling of all tissue layers of the pears tensa. The tissues were invaded by inflammatory cells and disintegrated. The fibrous layer also dissolved, leaving spontaneous perforations. However, phenol on inflamed TMs did not further alter the TM structure. These findings infer that the injurious effect of topical anesthesia on the intact TM is more or less negligible when applied to diseased TMs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...