Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 15 (1982), S. 403-408 
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Reaction detector ; Colorimetric detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A reaction detector with non-segmented flow in open tubes as reaction track is described. To minimize peak broadening the open tubes are arranged in a three dimensional coiled structure by knitting. At low volume flow rates the h-values in these open tubes are independent of flow rate and are significantly lower than predicted by theory. The applicability of this reactor for classical colorimetric detection with corrosive reagents is shown.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 559-565 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reaction detector ; Formaldehyde determination ; Trace analysis ; Cosmetic products
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The determination of free formaldehyde in the presence of its donators in cosmetic samples by a combination of reversed phase chromatography and post column reaction detection is described. The free formaldehyde is separated on a RP column with water as eluent from interfering formaldehyde-containing compounds and consecutively determined by the lutidine method in a reaction detector with knitted open tubes. With detection in the visible (420nm) the minimum detectable quantity is 40 ppb, with fluorimetric detection 15 ppb. The sample clean-up procedure for cosmetic products ranging from mascara to shampoo is by extracting the formaldehyde with water of pH 3, where the decomposition rate of the donators is minimal. Smaller amounts of free formaldehyde are always found compared to the standard lutidine method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 30 (1990), S. 523-526 
    ISSN: 1612-1112
    Keywords: Protein detection ; Protein hydrolysis ; OPA derivatization ; Reaction detector ; Micro wave
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The detection sensitivity for proteins can be improved significantly by microwave-enhanced hydrolysis and subsequent post-column OPA derivatization. Compared to native fluorescence detection the detection limit can be lowered by a factor between 60 and 120 depending on the amino acid composition of the protein. A hydrolysis time of 45 sec with a microwave energy of 750 watts is sufficient to reduce the detection limit to 0.04 μg/ml for BSA. Protein hydrolysis is not only enhanced by the higher temperature achieved but microwave irradiation seems to play a major role in improving the efficiency of the hydrolysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...