    ISSN: 1432-1238
    Keywords: Intrinsic PEEP ; Respiratory failure ; Pressure-controlled ventilation ; Inverse ratio ventilation ; Functional residual capacity ; Alveolar distension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives To study the ability of different ventilatory approaches to keep the lung open. Design Different ventilatory patterns were applied in surfactant deficient lungs with PEEP set to achieve pre-lavage PaO2. Setting Experimental laboratory of a University Department of Anaesthesiology and Intensive Care. Animals 15 anaesthetised piglets. Interventions One volume-controlled mode (L-IPPV201:1.5) and two pressure-controlled modes at 20 breaths per minute (bpm) and I:E ratios of 2:1 and 1.5:1 (L-PRVC202:1 and L-PRVC201.5:1), and two pressure-controlled modes at 60 bpm and I:E of 1:1 and 1:1.5 (L-PRVC601:1 and L-PRVC601:1.5) were investigated. The pressure-controlled modes were applied using “Pressure-Regulated Volume-Controlled Ventilation” (PRVC). Measurements and results Gas exchange, airway pressures, hemodynamics, FRC and intrathoracic fluid volumes were measured. Gas exchange was the same for all modes. FRC was 30% higher with all post-lavage settings. By reducing inspiratory time MPAW decreased from 25 cmH2O by 3 cmH2O with L-PRVC201.5:1 and L-PRVC601:1.5. End-inspiratory airway pressure was 29 cmH2O with L-PRVC201.5:1 and 40 cmH2O with L-IPPV201:1.5, while the other modes displayed intermediate values. End-inspiratory lung volume was 65 ml/kg with L-IPPV201:1.5, but it was reduced to 50 and 49 ml/kg with L-PRVC601:1 and L-PRVC601:1.5. Compliance was 16 and 18 ml/cmH2O with L-PRVC202:1 and L-PRVC201.5:1, while it was lower with L-IPPV201:1.5, L-PRVC601:1 and L-PRVC601:1.5. Oxygen delivery was maintained at prelavage level with L-PRVC201.5:1 (657 ml/min·m2), the other modes displayed reduced oxygen delivery compared with pre-lavage. Conclusion Neither the rapid frequency modes nor the low frequency volume-controlled mode kept the surfactant deficient lungs open. Pressure-controlled inverse ratio ventilation (20 bpm) kept the lungs open at reduced end-inspiratory airway pressure and hence reduced risk of barotrauma. Reducing I:E ratio in this latter modality from 2:1 to 1.5:1 further improved oxygen delivery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...