Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 72 (1999), S. 480-484 
    ISSN: 1432-1246
    Keywords: Key words Glycol ethers ; Percutaneous absorption ; In vitro experiments ; Skin absorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives: The increased use of glycol ethers (GEs) for water-based paints and cleaning products, combined with a lack of information about many of these products, particularly with regard to the effects of percutaneous exposure, led us to evaluate the skin absorption rates of a group of glycol ethers in vitro. Methods: Skin permeation was calculated using the Franz cell method with human skin. A physiological solution was used as the receiving phase. The amount of solvent passing through the skin was analysed with a gas chromatographic technique employing flame ionization detection. A permeation profile was obtained and steady state, lag time and permeation constant flux was calculated for each of the following solvents: ethylene glycol monoethyl ether (EGMEE), propylene glycol mono-methyl ether (PGMME); propylene glycol mono-methyl ether acetate (PGMMEac); 2-propylene glycol 1-butyl ether (2PG1BE), ethylene glycol dimethyl ether (EGDME), ethylene glycol diethyl ether (EGDEE) and diethylene glycol dimethyl ether (DEGDME). All solvents were tested in their pure form and with 70% acetone. Results: For all solvents tested the lag time was less than 2 h, and for the majority of them was about 60 min. Flux at steady state ranged between 0.017 ± 0.005 and 3.435 ± 1.897 mg/cm2/h and permeation rate was from 0.0192 to 1.02 × 10−3 cm/h. The presence of acetone in the solution caused a reduction in lag time and an increase in permeation rate, higher for EGMEE, lower for EGDEE, indicating the enhancing effect of this mixture of solvents. Conclusions: Our results confirm the high percutaneous absorption of the GEs tested. The Franz method might be helpful for obtaining a grading of skin notation for hydrophilic substances: in the case of glycol ethers, it can give us precise information about permeation risk, particularly important in the evaluation of exposure. In the case of solvents with high dermal absorption, the air concentration is no longer a sufficient measure of the total exposure to workers, and therefore merely respecting threshold limit values (TLVs) in the air is not necessarily enough to protect them.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...