    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 42 (1998), S. 634-641 
    ISSN: 0021-9304
    Keywords: biocompatibility ; subcutaneous implant ; implant surface ; microgrooves ; in vivo ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We investigated the behavior of microgrooved implants in soft tissue using polystyrene implantable disks, either smooth or microgrooved (1-10 μm) on both sides. The implants were placed subcutaneously in a goat for 1, 4, or 12 weeks. Light and transmission electron microscopy showed that fibrous capsule formation around the implants was fairly uniform. After 1 week the implants were covered with a fibrous capsule about 80 μm thick. The collagen matrix was loose, and many inflammatory cells were present. After 4 weeks the matrix was more dense and contained many newly formed blood vessels. At the implant surface a layer of inflammatory cells about 10 μm thick had accumulated. Finally, after 12 weeks the matrix had densified. One cellular layer of inflammatory cells was present at the implant surface. We carried out histomorphometric measurements of capsule thickness, inflammatory layer thickness, and the number of blood vessels. Capsule thickness appeared not to decrease with time. Further, these measurements showed that there were no differences in tissue reaction between smooth and microgrooved implants. On the basis of our observations, we suggest that 1 μm deep and 1-10 μm wide microgrooves do not influence tissue response around polystyrene implants in soft tissue. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 634-641, 1998.