Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Synchrotron radiation (SR) has been proved to be a powerful tool for x-ray study under pressure. So far, an energy dispersive method has been used because the intensity of the monochromatized beam is not strong enough for the very small sample under pressure, even if SR is used. In order to perform an angle-dispersive method under pressure, we need to use one- or two-dimensional detectors. Recently, a photostimulable fluorescence plate, named an imaging plate (IP), has been successfully used as an x-ray detector at the Photon Factory. We tried to combine a diamond anvil cell with SR and IP. Exposure time on IP for the diffraction from Ag in a diamond anvil cell at 22 keV is shorter than that on an x-ray film by a factor of 50. Resolution of IP (180 μm) is not a severe problem where IP is apart from the sample by 150 mm. Data on IP are digitally treated, so that it is easy to integrate the intensity along the Debye ring. Then, the reliability becomes more than 10 times better than a one-dimensional scan. Accuracy in determination of lattice constants and integrated intensity will be presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 59 (1991), S. 1401-1403 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A ZnSe/ZnSSe blue semiconductor laser was demonstrated to show very low threshold by direct photopumping of the ZnSe active layer. The lowest threshold at the excitation wavelength of 445 nm was 10 kW/cm2 at 300 K which is equivalent to the current density of 3.6 kA/cm2. This is the lowest threshold ever reported in II-VI photopumped lasers and is approaching the theoretically calculated threshold. The characteristic temperature of the threshold, which characterizes the temperature dependence of the threshold in the exponential form, was 124 K up to the measured 400 K and was comparable to III-V double-heterostructure lasers. The differential quantum efficiency remained the similar level up to 400 K and its decrease observed at 400 K was within 23% of the efficiency at 300 K.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 107 (1985), S. 1427-1429 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 34 (1995), S. 2870-2874 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 1666-1667 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The characteristics of argon electron cyclotron resonance plasma discharged by 7.0, 8.0, and 9.4 GHz microwaves were investigated. Experiments were conducted in a fixed magnetic field. It was found that the electron temperatures Te exhibited a trend of Te7.0〈Te8.0〈Te9.4 (suffixes represent the discharge microwave frequencies). © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 53 (1998), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We have studied the recovery of post-tetanic count and train-of-four responses at the great toe and thumb accelerographically after the administration of vecuronium 0.2 mgkg−1. Sixty adult patients scheduled for anaesthesia with nitrous oxide and isoflurane were studied. The times to the return of the first post-tetanic twitch were comparable at the great toe and thumb (mean (SD) times: 30.0 (6.5) min and 35.0 (8.5) min, respectively). Recovery of post-tetanic count followed similar time courses at the great toe and thumb. Also, time to the return of the first twitch of the train-of-four did not differ significantly at the great toe and thumb (47.5 (9.6) min vs. 49.7 (10.5) min). Similarly, time to the return of the second, third and fourth twitches of the train-of-four did not significantly differ at the great toe and the thumb. However, the value of the first twitch of the train-of-four, expressed as a proportion of control twitch, was significantly higher than that at the thumb between 50 min and 110 min after the vecuronium injection, and the train-of-four ratio at the great toe was significantly higher than that at the thumb between 60 min and 100 min after the vecuronium injection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The efficacy of granisetron, droperidol and metoclopramide for the prevention of postoperative nausea and vomiting in female patients undergoing middle ear surgery was compared. In a randomised, double-blind study, 180 patients received granisetron 40 μg.kg−1, droperidol 20 μg.kg−1 or metoclopramide 0.2 mg.kg−1 given intravenously immediately before induction of anaesthesia (n = 60 for each). A standardised general anaesthetic technique was employed throughout. A complete response, defined as no postoperative nausea and vomiting and no need for another rescue anti-emetic, during the first 3 h after anaesthesia was achieved in 83%, 58% and 55% of patients who had received granisetron, droperidol and metoclopramide, respectively. The corresponding incidence during the next 21 h after anaesthesia was 85%, 54% and 47% (p 〈 0.05). No clinically important adverse effects were observed in any of the groups. We conclude that prophylactic therapy with granisetron is superior to droperidol or metoclopramide in the prevention of postoperative nausea and vomiting after middle ear surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 54 (1999), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated the accelographic train-of-four response evaluated at the great toe at varying stimulating currents. Fifteen adult patients undergoing elective general anaesthesia were studied. The mean current at which a supramaximal T1 value could be elicited was 〉 49 (9) mA [mean (SD)]. Ratios of accelographic T1 values at 50, 40, 30, 20 and 10 mA to accelographic T1 value at 60 mA were 0.90 (0.18), 0.58 (0.37), 0.38 (0.37), 0.19 (0.26) and 0.00 (0.00), respectively [mean (SD), p 〈 0.05 for 50 mA vs. 30, 20 and 10 mA, p 〈 0.05 for 40 mA vs. 20 and 10 mA, and p 〈 0.05 for 30 vs. 10 mA]. Threshold currents for train-of-four (the lowest currents at which any train-of-four response could be elicited) before and after induction of anaesthesia were 30 (10) and 31 (10) mA, respectively. The train-of-four ratio (T4/T1) measured at varying currents did not differ significantly. However, in the patients in whom threshold currents for train-of-four were 40, 30 and 20 mA, the train-of-four ratio recorded at the threshold current was significantly less than at 50 mA. We conclude that at the great toe, the mean current at which a supramaximal response to train-of-four can be yielded is as high as 〉 49 mA. The mean threshold currents for TOF before and after induction of anaesthesia were 30 and 31 mA, respectively. Train-of-four ratio measured at the threshold current is less than that at 50 mA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 632-634 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A compact electron cyclotron resonance (ECR) ion source (compact ECRIS) for the mass spectrometer was tested. A feature of the compact ECRIS is its size, i.e., inner diameter: 22.5 mm (1 in. tube), length: 56 mm. ECR plasmas in this ion source using argon gas were discharged by high-frequency microwaves, 7–10 GHz. It was confirmed that the plasma was generated in the pressure range 30–410 mPa at the low input power of 5 W. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1365-2559
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Aims : To investigate whether Glia maturation factor-β (GMFB) is expressed in thymomas and is associated with T-cell development.Methods and results : We investigated the expression of GMFB by immunohistochemistry in 86 cases of thymoma classified into five type A, 35 type AB, 11 type B1, 26 type B2, and nine type B3 thymomas according to the World Health Organization classification system. Immunoblotting and in situ hybridization (ISH) studies were also performed in selected cases. The results of the immunoblot analysis were in accordance with those of immunohistochemical scoring. The ISH study ascertained the tumour cells producing the protein. Immunohistochemically, GMFB expression was observed in one (20%) of type A, 32 (80%) of type AB, all (100%) of type B1 and B2, and eight (89%) of type B3 thymoma with statistically significant differences between type A and type AB, type B1, or type B2 thymoma, and between type B3 and type AB or type B2 thymoma. There was a significant correlation between GMFB expression and the amount of accompanying non-neoplastic T cells. GMFB promoted T-cell differentiation into CD4–/CD8+ cells when analysed by two-colour flow cytometry.Conclusions : The present study suggests that T-cell development in thymoma may be maintained partly by GMFB produced by the tumour cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...