Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    ISSN: 0942-0940
    Keywords: Gamma Knife ; MRI ; Stereotactic atlas ; rat ; stereotactic device
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Stereotactic devices for experimental Gamma Knife irradiation and magnetic resonance imaging (MRI) have recently been developed for experimental studies using rats [6, 7]. The present study examined the accuracy of these devices using the following two approaches. In the first approach, Gamma Knife irradiation was performed using the stereotactic device with targets based on a standard stereotactic atlas. Gadolinium-enhanced T1-weighted magnetic resonance imaging was performed using the MRI stereotactic device. Animals were then sacrificed after Evans blue injection, and the rat brain was sliced using an attachment to the stereotactic device. The center coordinates of the gadolinium-enhanced area from the MRI and Evans blue-stained area from the tissue sections were obtained using a computer-assisted image analysis system. These coordinates were compared with the target coordinates planned from the stereotactic atlas. In the second approach, a thermoluminescence dosimeter was implanted in the rat brain. Stereotactic MRI was performed using the stereotactic MRI device, and the coordinates of the implant were obtained. Gamma Knife irradiation was then performed at this target using the stereotactic device. The absorbed dose was measured and compared with the planning dose. These experiments demonstrated a spatial error of 0.6 mm (standard error ± 0.07) between Gamma Knife irradiation based on a comparison of the atlas coordinates and the lesion, and a spatial error of 1.0 mm (standard error ± 0.13) based on a comparison of the stereotactic MR images and the lesion. Gamma Knife irradiation based on MR images using the stereotactic device demonstrated a maximum error of 10% in absorbed dose at the target center. Together, the stereotactic devices for Gamma Knife irradiation and magnetic resonance imaging provide useful tools for Gamma Knife research in an animal model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 132 (1995), S. 138-144 
    ISSN: 0942-0940
    Keywords: Stereotactic surgery ; mycotic aneurysm ; laser guidance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The Steiner-Lindquist laser intra-operative guidance method is described and its application in the surgical treatment of mycotic aneurysm is presented. Three illustrative cases of distal middle cerebral artery aneurysms are reported. The authors argue that all ruptured mycotic aneurysms should be treated surgically. The laserguided stereotactic approach is presented as simple, flexible and reliable method to improve safety and accuracy of the operation in these cases. In our experience it compares favorably with previously described stereotactic techniques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 139 (1997), S. 259-260 
    ISSN: 0942-0940
    Keywords: Cavernous sinus ; meningioma ; paedriatic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...