Library

You have 0 saved results.
Mark results and click the "Add To Watchlist" link in order to add them to this list.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 313-345 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Sample pretreatment ; Coupling on-line to capillary GC ; Robotization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; On-line coupling ; Ion-exchange membrane ; Ion-pair reagent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant in the membrane was tetrabutylammonium hydroxide dissolved in acetonitrile/water, which effects an anion-exchange of methanesulphonate ions for regenerant hydroxide ions. The efficiency of the exchange process was found to be 99.9%. This enabled the direct introduction of the LC eluent, free of ions and with the proper acetonitrile/water ratio, into the GC. The applicability of the on-line LC-micromembrane-GC system has been illustrated for the potential drug eltoprazine, which is quantitatively recovered with a coefficient of variation for standard solutions of 3% at the 150 μg/ml analyte level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...