Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1569-8041
    Keywords: bone marrow scintigraphy ; immunoscintigraphy ; malignant lymphoma ; Tc-99m labelled anti-NCA-95
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: The purpose of this study was to elucidate the clinical reliability of immunoscintigraphy (IS) to detect infiltration of the bone marrow in patients with malignant lymphoma. Patients and methods: Whole body IS was performed in 103 patients with Hodgkin's disease (HD) or non-Hodgkin's lymphoma (NHL) using Tc-99m labelled anti-NCA-95 which allows visualization of the granulopoietic bone marrow. Of these, 52% were studied prior to any therapy. Findings were compared to posterior iliac crest biopsy as well as MRI and/or follow-up examination. Criteria of marrow infiltration were a positive biopsy, positive follow-up, or positive results of MRI. Results: Comparison of IS and biopsy revealed concordant findings in 69 and discordant findings in 34 of 103 patients. Of the 34 patients with discordant results, IS showed lesions suspicious of bone marrow infiltration in 29 patients despite normal biopsy findings. When follow-up and additional examinations were taken into consideration, 10 patients remained with probably false positive and five with false negative IS findings. IS proved to be highly sensitive and specific in patients with HD (100% and 84%, respectively) and high-grade NHL (93% and 84%, respectively). Moderate sensitivity (60%) was found in low-grade NHL. This was possibly due to false negative IS in three to five patients with chemotherapy in contrast to one of five false negative results in patients without chemotherapy. Conclusion: Bone marrow scintigraphy using antigranulocyte antibodies is highly sensitive in HD and high-grade NHL. Positive findings in IS subsequent to a negative biopsy should be followed by guided re-biopsy or MRI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 40 (2000), S. 751-753 
    ISSN: 1432-2102
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1084
    Keywords: Key words: Lung neoplasms ; Staging ; Pleura ; CT
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this investigation was to evaluate whether thin-sectional CT with different reconstruction algorithms can improve the diagnostic accuracy with regard to chest wall invasion in patients with peripheral bronchogenic carcinoma. Forty-one patients with intrapulmonary lesions and tumor contact to the thoracic wall as seen on CT staging underwent additional 1-mm CT slices with reconstruction in a high-resolution (HR) and an edge blurring, soft detail (SD) algorithm. Five criteria were applied and validated by histological findings. Using the criteria of the intact fat layer, HRCT had a sensitivity of 81 % and a specificity of 79 %, SD CT had a sensitivity of 96 % and a specificity of 78 %, and standard CT technique had a sensitivity of 50 % and a specificity of 71 %, respectively. Regarding changes of intercostal soft tissue, HRCT achieved a sensitivity of 71 % and a specificity of 96 %, SD CT had a sensitivity of 94 % and a specificity of 96 % (standard CT technique: sensitivity 50 % and specificity 96 %) . For the other criteria, such as pleural contact area, angle, and osseous destruction, no significant differences were found. Diagnostic accuracy of chest wall infiltration can be improved by using thin sectional CT. Especially the application of an edge-blurring (SD) algorithm increases sensitivity and specificity without additional costs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...