Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1076
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1076
    Keywords: W170 ; Aerobic capacity ; Validity ; Congenital heart disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 20 Jungen und 23 Mädchen im Alter von 6–16 Jahren mit unterschiedlichen Herzfehlern wurde die W170, d. h. die Leistung bei einer Herzfrequenz von 170/min, und die maximale O2-Aufnahme in einem Arbeitsgang bestimmt. Sowohl die W170-Werte als auch die Werte der maximalen O2-Aufnahme wurden unter Berücksictigung von Alter und Körperlänge zu entsprechenden Normwerten in Beziehung gesetzt. Für die Beziehung zwischen W170 und maximaler O2-Aufnahme fanden sich Korrelationskoeffizienten zwischen 0,36 und 0,66. Das bedeutet, daß nur zwischen 13 und 44% der Varianz der maximalen O2-Aufnahme durch die W170 abgedeckt waren. Die unvollkommene Übereinstimmung zwischen indirekt und direkt bestimmter kardiovasculärer Leistungsfähigkeit beruhte zum Teil auf der erheblichen Variabilität der maximalen Herzfrequenz. Dementsprechend ergaben sich für die Beziehung zwischen maximaler Herzfrequenz einerseits und der Differenz zwischen den prozentualen Werten der maximalen O2-Aufnahme und der W170 andererseits in den verschiedenen Gruppierungen Korrelationskoeffizienten zwischen 0,28 und 0,69. Der Fehler einer indirekten Bestimmung mit Hilfe der W170 ist also in der Regel um so größer, je stärker die maximale Herzfrequenz vom Gruppenmittelwert abweicht. Die Beurteilung der kardiovasculären Leistungsfähigkeit mit Hilfe der W170 fiel besonders bei jüngeren Kindern deutlich besser aus als mit Hilfe der maximalen O2-Aufnahme. Die Ursache hierfür liegt wahrscheinlich darin, daß bei den jetzigen Untersuchungen ein anderer Ergometertyp verwandt wurde als bei der Ermittlung der Normwerte der W170, die auch bei den jetzigen Untersuchungen zugrunde gelegt wurden. Wir vermuten, daß die unterschiedliche Schwungmasse verschiedener Ergometertypen trotz gleicher Eichung über einen unterschiedlichen Wirkungsgrad einen Einfluß auf die Bestimmung der W170 hat.
    Notes: Abstract W170, i.e., the work rate at a heart frequency of 170 beats per minute, and maximal oxygen uptake were determined in one performance in 20 boys and 23 girls from 6 to 16 years of age on a bicycle ergometer. The results were related to normal values according to age and height. In different age and sex groups correlation coefficients between W170 and maximal oxygen uptake amounted to values between 0.36 and 0.66. Accordingly only 13–44% of the variance of maximal oxygen uptake were covered by W170. The imperfect conformity between indirectly and directly measured cardiovascular performance capacity was due to the considerable variability of the maximal heart rate. Accordingly we found correlation coefficients from 0.28 to 0.69 for the relations between maximal heart rate on the one hand and the difference between percentage values of maximal oxygen uptake and W170 on the other hand. That means that the error of an indirect determination by means of the W170 is mostly higher, the more the maximal heart rate differs from the mean value of the group. The estimation of cardiovascular performance capacity by means of the W170 yielded higher relative values than by means of the maximal oxygen uptake. The reason for this is probably that in our present investigations we used another type of ergometer than that we had used earlier for determination of normal values of W170, to which we referred in our present investigations. We suggest that the different gyrating mass of different types of ergometers in spite of identical calibration may influence the results via a different mechanical efficiency.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1435-1803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An insgesamt 36 Kindern ohne Shuntvitien wurden etwa 280 Impedanzmessungen vorgenommen, um die Aussagekraft der Impedanzkardiographie über die Größe von Herzzeit- bzw. Herzschlagvolumina prüfen zu können. Zur Auswertung der Impedanzkardiogramme wurden pro Kind bis zu 22 Kombinationen von Meßbedingungen und Auswerteverfahren herangezogen. Als Bezugsmethode diente dasFicksche Prinzip. Die Reproduzierbarkeit der Impedanzmessungen war sehr gut, eine Übereinstimmung zwischen den Ergebnissen der Impedanzkardiographie mit den entsprechenden Werten derFickschen Methode bestand jedoch nicht. Es gibt Gründe für die Annahme, daß die Impedanzkardiographie lediglich herzsynchrone Schwankungen des intrathorakalen Flüssigkeitspegels widerspiegelt, von denen aus formalen Gründen jedoch nicht auf das Ausgangsschlagvolumen geschlossen werden sollte. Außerdem sprechen physikalische Gründe gegen eine quantitative Erfaßbarkeit dieser Volumenschwankungen.
    Notes: Summary In 36 children without shunts nearly 280 electrical impedance measurements were carried out in order to estimate the accuracy of the impedance cardiography as a means of calculating cardiac output. During evaluation up to 22 combinations of test conditions and possibilities of evaluation per child were tested. As a reference method theFick Principle was used. The reproducibility of impedance measurements showed itself to be high, but no agreement of the results by impedance cardiography and corresponding values by theFick method could be found. Some reasons give rise to suppose that impedance cardiography only reflects changes of the intrathoracic fluid level occurring during heart action from which because of formal reasons no inference should be drawn about the original cardiac output. Besides physical arguments tell against the possibility of picking up these volume-changes quantitatively by analyzing transthoracic electrical impedance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...