Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 659-664 
    ISSN: 0935-6304
    Keywords: Splitless injection, 100 μl volumes ; Injector insert, packing of ; Sample evaporation in vaporizing injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: If a sample evaporates by flash vaporization in an empty injector insert, the solute material is well mixed with the expanding solvent vapors and the maximum injection volume is determined by the requirement that no vapors must leave the vaporizing chamber. If evaporation occurs from a surface (e.g., of Tenax packing), however, the solvent evaporates first. The site of evaporation is cooled to the solvent's boiling point, and the cool island formed in the hot injector retains solutes of at least intermediate boiling point (visually observed for perylene). Solvent vapors, free from such solutes, may now expand backwards from the injector insert and leave through the septum purge exit. When solvent evaporation is complete, the site of evaporation warms up, causing the high boiling solutes to evaporate and to be carried into the column by the carrier gas. The technique somewhat resembles PTV injection, but is performed using a classical vaporizing injector.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 715-722 
    ISSN: 0935-6304
    Keywords: Splitless injection, large volumes ; Injector insert ; packing of Vapor overflow ; splitless injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Sample evaporation in splitless injection of large volumes is rapid: depending on the experiment, results indicate that 200 μl of hexane, for instance, evaporates in 2-10 s, producing vapor at a rate of many hundreds of milliliters per minute. A 60 × 4 mm packed bed of 20-35 mesh Tenax TA enabled injection of 200 μl volumes of all solvents tested, and even 1 ml injections were possible provided they were performed over a period of 30 s. Retention of volatile sample components depends on the sample solvent, the injection volume, and the injection speed, but only little on the injector temperature. Losses of n-tridecane varied from hardly 15 % (when dissolved in pentane) to ca 60 % (ethyl acetate); losses of n-heptadecane were usually below 20 %. The column temperature during injection should be at least ca 20-30°C above the standard solvent boiling point.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...