Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-4838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Four different implant materials were installed into the mandibular corner of goats to investigate the trabecular bone response in a mainly unloaded model. The implants were installed using a standardized technique and were left in situ for 12 weeks. One goat had to be sacrificed after surgery because of a broken rib; the other animals healed uneventfully. After sacrifice of the animals, the bone response to the uncoated and the three different Ca–P implants was evaluated histologically and histomorphometrically. Four sections of each implant were evaluated; two were located in the cortical and two in the trabecular bone. Of the 44 retrieved implants, 20 implants appeared to be installed partially in the mandibular canal, as clearly visible on the X-rays. These implants were not used in the histomorphometrical measurements. Histological evaluation showed that the trabecular and cortical bone reactions were similar; there was no significant difference in the percentage of bone contact nor in the amount of bone in contact with the implants. In conclusion this study showed that the mandibular corner is an unsatisfactory model for the installation of implants because of anatomical restrictions. Also, the experiment remained inconclusive about the influence of loading conditions on bone behaviour. Nevertheless, the histological results confirmed the bioactive properties of Ca–P coatings.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brånemark® implants were inserted in the trabecular bone of the maxilla. Before the insertion of the implants, the two first upper premolars of 16 goats were bilaterally extracted. Four months later, each animal received four types of implants: three different Ca-P-coated types and one uncoated. After an endosseous period of 6 months, the implants were provided with permucosal abutments. Four months later the animals were killed. At the end of the experiment, it appeared that 10 of the 16 installed noncoated implants had failed while of the 48 Ca-P-coated implants, only 6 had failed. All successful implants were retrieved and prepared for histomorphometrical evaluation of the bone and gingiva response. The Ca-P-coated implants showed a significantly greater percentage of bone in contact with the implant surface compared with the uncoated implants. The length of the epithelium was not significantly different for the coated compared to the uncoated implants, but the connective tissue was significantly thicker for the noncoated implants than for the Ca-P-coated implants. Also, measurements revealed that all coatings showed reduction in thickness. On the basis of these findings, we concluded that the application of Ca-P coatings (1) improves the bone-implant reaction, although all coatings reduced in thickness, and (2) is of benefit during the healing period in less mineralized trabecular bone. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 1061-1069 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The trabecular bone response to noncoated and fluorapatite (FA), hydroxyapatite (HA), and hydroxyapatite heattreated (HAHT) plasma-sprayed coated implants was investigated in a goat animal model. Forty-eight cylindrical implants were inserted into the trabecular bone of the lateral and medial femoral condyles of twelve goats according to a split plot design. After an implantation period of twelve weeks, the bone-implant interface was evaluated histologically. Quantitative histomorphometrical measurements demonstrated a significant difference in bone contact between implants inserted in the lateral and medial condyles. In addition, a significant difference in bone apposition was observed between the coated and the uncoated implants. Finally, all Ca-P coatings showed reduction in coating thickness. Measurements revealed that FA and HAHT showed less reduction in coating thickness than HA coating. Despite the coating reduction, the bone remained in close contact with the implant surface. © 1995 John Wiley & Sons, Inc.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The response of bone of low density to uncoated, fluorapatite (FA), hydroxyapatite (HA), and hydroxyapatite heat treated (HAHT) plasma-sprayed coated implants was investigated 3 and 6 months after installation. Forty-eight threaded implants of commercially pure titanium were inserted into the maxilla of twelve goats according to a split-plot design. One goat died shortly after installation of the implants, five goats were sacrificed 3 months after installation, and the other six goats 6 months after installation. Histological evaluation revealed no difference in bone reaction between the 3- and 6-month implantation periods. In addition, probably due to the wide inter- and intra-animal variability, no significant difference between the 3- and the 6-month periods could be observed in the histomorphometrical measurements performed. Further, no significant differences were found in bone reaction among the various implant materials. Finally, qualitatively it appeared that all coatings showed reduction in coating thickness and that such reductions were most pronounced for the HA coatings. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...