Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1459
    Keywords: Key words Multiple sclerosis ; Brain magnetic resonance imaging ; Repositioning ; Clinical trials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to assess the variability of lesion load measurements for repeated brain magnetic resonance imaging (MRI) scans judged to have either poor or good repositioning quality on the basis of subjective criteria used for clinical trials in multiple sclerosis (MS). Scan-rescan variability was also compared with the intra-observer variability assessed from three repeated volume measurements of the same scan. Nine patients with MS were studied; each of them underwent the scan-rescan procedure on the same day. Five scans were considered to have poor and four scans to have good repositioning. Between these two groups there were no differences in either the mean lesion loads or the measurement variance. For the whole group of patients, the intra-observer variability of repeated measurements gave a significantly lower coefficient of variation (COV=4.9%) than the variability owing to repositioning (COV=8.9%, P〈0.01, F test). Our results confirm that the effect of repositioning on brain MRI lesion load assessment is stronger than that owing to the intra-observer variability for repeated measurements and indicate that the simple visual judgment about the scan repositioning quality seems unable to predict the scan-rescan reproducibility.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1459
    Keywords: Key words Multiple sclerosis ; Brain ; Spinal cord ; Magnetic ; resonance imaging ; FLAIR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Recent reports have suggested that fluid attenuated inversion recovery (FLAIR) is a technique superior to conventional (CSE) or fast spin echo (FSE) T2-weighted sequences in detecting intrinsic lesions both in the brain and spinal cord. We report our experience of an inversion recovery prepared FSE, which we refer to as fast FLAIR, in a comparative study of ten patients with clinically definite multiple sclerosis (MS) who underwent cervical cord and brain imaging with both FSE and fast FLAIR. The results showed that in the cerebral hemispheres fast FLAIR detected more lesions than FSE (P 〈 0.001). However, FSE detected more lesions than fast FLAIR in the posterior fossa (P = 0.02) and in the cord fast FLAIR was much inferior detecting only 2 of 33 lesions seen on FSE. Estimating the T2 relaxation times of lesions in each of three areas (periventricular, posterior fossa, cervical cord) showed that the T2 value of posterior fossa and cervical cord lesions was significantly lower than that of periventricular lesions, suggesting that the lesion composition is different and consequently their imaging appearances are different. In conclusion, although fast FLAIR improves the detection of MS lesions in the cerebral hemispheres, its substantially lower sensitivity in the posterior fossa and spinal cord is a potentially important limitation to its use as a tool for the diagnosis of MS and for monitoring therapies. Further studies are needed to elucidate the mechanisms underlying the loss of sensitivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...