  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Neurosurgical review 17 (1994), S. 237-239 
    ISSN: 1437-2320
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Neurosurgical review 22 (1999), S. 173-187 
    ISSN: 1437-2320
    Schlagwort(e): Key words Stereotaxy ; Accuracy ; Localisation frame ; Computed tomography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  The accuracy of coordinate transformation from the computed tomographic (CT) space to the stereotactic frame space was analysed for frame-based stereotactic systems which use a localisation frame and coordinate transformation based on matrix calculation. The coordinate transformation was divided into three consecutive steps: (1) transforming the localisation frame into the CT image built up from pixels with distinct attenuation values, (2) determining the rod centres of the localisation frame in the CT image, and (3) coordinate transformation from the image to the frame space using the centres of the rods in the image space and algebraic, matrix-based calculation. The error contribution at each step was evaluated separately and its effect on the subsequent mathematical operations was analysed. The first step dealt with the influences of the mathematical and physical properties of the CT on the image of the localisation frame. Noise, slice thickness, convolution filter, dimension of the pixel matrix, and image processing had an influence on the attenuation values in each pixel. Above all, the slice thickness had an effect on the shape of the oblique rods in the CT image. At the second step, the main error contribution was due to the method by which the centre of the rods was calculated. The most accurate method was to determine the centre of gravity using the attenuation values as single mass points (with accuracy in the range of ±1/10 pixel, or ±0.125 mm), followed by rounding off the centre of gravity and the highest pixel value in the square matrix R2(N) within 1 pixel. Pointing with a cursor under visual control was accurate to 1 pixel and the pixel with the highest attenuation value showed deviations of up to 2 pixels in the x and y axes. Thus, the methods differed by a factor of 20. The influence of the CT mathematics and physics on the determination of the centre of the fiducials was negligible in comparison to the method of calculation used. There was no systemic error due to the filtred back projection algorithm. Data input errors due to noise were in the range of 1/10 pixel. The effects of the remaining physical influences were all in the range of the error due to noise. In particular these results speak in favour of no influence of slice thickness on coordinate transformation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Neurosurgical review 21 (1998), S. 213-214 
    ISSN: 1437-2320
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Neurosurgical review 22 (1999), S. 188-203 
    ISSN: 1437-2320
    Schlagwort(e): Key words Stereotaxy ; Accuracy ; Localisation frame ; Coordinate transformation ; Computer simulation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  The accuracy of coordinate transformation from a CT image to a stereotactic frame was investigated for stereotactic systems using a localisation frame and matrix-based coordinate transformation. The main source of error influencing calculation was input data, due to inaccurate calculation of the centres of the rods of the localisation frame in the CT image, and the propagation of this input error during subsequent matrix calculation. Systemic errors during matrix calculation do not exist, and rounding off errors were of subordinate importance compared to the input data error. The influence of input data error on coordinate transformation was studied by geometric methods, computer simulation, and numerical analysis. In the geometric model, input data errors affected the calculation of the centres of the three oblique rods in the frame space and shifted them three points upwards or downwards on the axis of each rod. The three centres of the oblique rods defined the ”CT plane” in the 3D space of the stereotactic frame. Displacements of these three centres caused a characteristic tilting of the CT plane. The positions of the correct and tilted CT planes defined the spatial error properties for all target points on the CT plane. The computer simulation investigated the effects on matrix-based transformation of all possible displacement combinations on the three oblique rods by 1 pixel (1.16 mm) in the x and y directions. A characteristic, space-dependent distribution of the frame-related coordinates was obtained for each target point. In the centre of the frame, we found a maximal deviation of 1.0 mm in the xy direction and 2 mm in the z direction. This corresponded to an error amplification of 0.73 in the xy direction and 1.22 in the z direction relative to the error at the centres of the rods. The maximum deviation (found in the periphery) for all combinations on the three oblique rods was 1.7 mm in the xy direction and 3.3 mm in the z direction. This resulted in an amplification of 1.03 in the xy direction and 2.01 in the z direction. This results had to be multiplied by 2 to obtain a maximal error estimate for displacements including all nine rods of the localisation frame. Numerical analysis showed stable solutions with low error amplification for hexagonal frame arrangements.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Neurosurgical review 23 (2000), S. 205-205 
    ISSN: 1437-2320
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Acta neurochirurgica 115 (1992), S. 152-155 
    ISSN: 0942-0940
    Schlagwort(e): Stereotactic biopsy ; Doppler techniques ; cerebral vessels
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The use of a 20 MHz pulsed Doppler technique during stereotactic brain tumour biopsies is described. By means of a miniaturized ultrasonic probe the tissue planned for biopsy was investigated for vessel signals. Out of 41 patients, with this technique a flow-pulse curve in front of the biopsy cannula was registered in 14 cases. In 9 cases one pulse curve was determined and in 5 cases two or more flow curves were found, indicating the presence of arterial vessels. The depth of the vesses signal could be localized and this area avoided for biopsy sampling. In a series of 41 Stereotactic biopsies carried out in this way there was no intra-operative haemorrhage or postoperative haematoma.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...