Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: Key words Perflubron ; Partial liquid ventilation ; Nitric oxide ; ARDS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To assess the effects of increasing concentrations of inhaled nitric oxide (NO) during incremental dosages of partial liquid ventilation (PLV) on gas exchange, hemodynamics, and oxygen transport in pigs with induced acute lung injury (ALI). Design: Prospective experimental study. Setting: Experimental intensive care unit of a university. Subjects: 6 pigs with induced ALI. Interventions: Animals were surfactant-depleted by lung lavage to a partial pressure of oxygen in arterial blood (PaO2) 〈 100 mmHg. They then received four incremental doses of 5 ml/kg perflubron (LiquiVent). Between each dose the animals received 0, 10, 20, 30, 40, and 0 parts per million (ppm) NO. Measurements and main results: Blood gases, hemodynamic parameters, and oxygen delivery were measured after each dose of perflubron as well as after each NO concentration. Perflubron resulted in a dose-dependent increase in PaO2. At each perflubron dose, additional NO inhalation resulted in a further significant (ANOVA, p 〈 0.05) increase in PaO2, with a maximum effect at 30 ± 10 ppm NO. The 5 ml/kg perflubron dose led to a significant decrease in mean pulmonary artery pressure, which decreased further with higher NO concentrations. Conclusions: PLV can be combined with NO administration and results in a cumulative effect on arterial oxygenation and to a decrease in pulmonary artery pressure, without having any deleterious effect on measured systemic hemodynamic parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Hemodynamics ; Gas exchange ; Mechanical ventilation ; Oxygen ; Perfluorocarbon ; Respiratory distress syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To assess the effect of partial liquid ventilation with perfluorocarbons on hemodynamics and gas exchange in large pigs with induced acute lung injury (ALI). Design Randomized, prospective, double-control, experimental study. Setting Experimental intensive care unit of a university. Materials Eighteen large pigs (50±5 kg body weight) with an average anterior posterior thoracic diameter of 24 cm and induced acute lung injury. Interventions All animals were surfactant depleted by lung lavage to aP aO2 below 100 mmHg and randomized to receive either perflubron (n=6) or saline (n=6) in five intratracheal doses of 5 ml/kg at 20-min intervals, or no instillation (n=6). Measurements and results In all animals heart rate, arterial pressures, pulmonary pressures, cardiac output and blood gases were recorded at 20-min intervals. There was no deleterious effect on any hemodynamic parameter in the perflubron group, whereas systolic and mean pulmonary arterial pressure values showed a persistent decrease after the first 5 ml/kg of perflubron, from 48.7±14.1 to 40.8±11.7 mmHg and from 39.7±13.2 to 35.2±12.0 mmHg, respectively. Perflubron resulted in a significant (ANOVAP〈0.01), dose-dependent increase inP aO2 values from 86.3±22.4 to a maximum of 342.4±59.4 mmHg at a dose of 25 ml/kg; the other groups showed no significant increase inP aO2. Conclusions Tracheal instillation of perflubron in induced ALI results in a dose-dependent increase inP aO2 and has no deleterious effect on hemodynamic parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...