Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 30 (2003), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  The purpose of this study was to examine the relationship between masticatory performance and maximal occlusal force in dentate subjects, using test foods of varying hardness. Subjects were 20 young males with natural dentitions. Gummy jellies with two different degrees of hardness have been used as test foods to evaluate masticatory performance. Masticatory performance was evaluated by the increase of the surface area of expectorated pieces of comminuted gummy jelly that was calculated from the concentration of gelatin. Maximal occlusal force was measured with pressure sensitive sheets (DENTAL PRESCALE™ 50H R type). The results suggested that maximal occlusal force had a significant positive correlation to the masticatory performance both with soft gummy jelly and hard gummy jelly. The correlation coefficient (r) with hand gummy jelly tended to be larger than with soft gummy jelly.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  Recently, a newly developed magnetic attachment with stress breaker was used in retentive components in overdentures. Excessive lateral stress has a more harmful effect on natural teeth than axial stress, and the magnetic attachment with stress breaker is expected to reduce lateral forces on abutment teeth and protect it teeth from excessive stress. However, the properties of this retainer have not yet been determined experimentally. This study compares the lateral forces on abutment teeth for three retainers under loading on the denture base in a model study. A mandibular simulation model is constructed to measure lateral stress. Three types of retentive devices are attached to the canine root. These devices include the conventional root coping, the conventional magnetic attachment and the new magnetic attachment with stress breaker. For each retentive device, load is generated on the occlusal table of the model overdenture, and the lateral stress on the canine root and the displacement of the overdenture measured. The magnetic attachment with stress breaker does not displace the denture and exhibits lower lateral stress in the canine root than conventional root coping and magnetic attachments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of environmental contamination and toxicology 21 (1979), S. 526-532 
    ISSN: 1432-0800
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...