Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Melbourne, Australia : Blackwell Science Pty
    International journal of urology 9 (2002), S. 0 
    ISSN: 1442-2042
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: We report here an extremely rare case of cystosarcoma phyllodes of the seminal vesicle.Methods: A 65-year-old man presented with urinary hesitancy, frequency and constipation. Clinical examinations including two needle biopsies were performed, and the patient had undergone open surgery.Results: The final pathological diagnosis was cystosarcoma phyllodes of the seminal vesicle. Seven months after the operation, a chest X-ray showed lung metastasis, and the patient died 11 months after the operation.Conclusion: To our knowledge, only one case of cystosarcoma phyllodes of the seminal vesicle has been previously reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 23 (1994), S. 471-474 
    ISSN: 1432-2161
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2161
    Keywords: Transpedicular screw ; Isthmic diameter ; Pedicle ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The isthmic diameter of the vertebral pedicle is an important dimension affecting the stability of transpedicular screwing. The isthmic diameter of the pedicle was measured in the lumbar spines of 18 Japanese cadavers (10 male, 8 female) by axial computed tomographic (CT) scan and directly with calipers. In L1 and L2, there was no significant difference between the average value of the isthmic diameter as determined by the two methods (Student's t-test). However, in L3-5, the average value of the isthmic diameter as determined by axial CT scan was significantly greater than that given by caliper measurement. In view of the fact that caudally the longitudinal axis of the pedicle diverges to wards the mid-line of the vertebral body in the coronal plane, the plane of the CT scan cannot be parallel to the real isthmic diameter of the pedicle. Therefore, it is suggested that below L2 the diameter as determined by axial CT scanning is greater than the real isthmic diameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 61 (1996), S. 859-863 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Transparent polymeric materials with high heat resistance and low water absorption were designed based on the alternating copolymers of N-substituted maleimide (RMI) with isobutene (IB). The N-substituent of the maleimide significantly affected the glass transition temperature (Tg) and water absorption of the copolymers. Poly(N-cyclohexylmaleimide-alt-JB) [poly(CHMI-IB)] showed a Tg value as high as 192°C and relatively low water absorption. Furthermore, the incorporation of a small amount of lauryl methacrylate in the copolymers was confirmed to reduce the water absorption of the copolymer drastically, although it decreased the Tg of the copolymers at the same time. Poly(CHMI-IB), containing 4 mol % lauryl methacrylate, showed a good balance of excellent transparency, high heat resistance, acceptable mechanical properties, and low water absorption. The heat deflection temperature was as high as 141°C. The water absorption at 23°C after immersion for 14 days was 0.56% and the dimensional change after 7 days was 0.06%. They are half and one-quarter of those of poly(methyl methacrylate), respectively. © 1996 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...