    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 234 (1996), S. S142 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract • Background: Excimer laser trephination, as an alternative to mechanical trephination of the cornea in penetrating keratoplasty, is expected to reduce long-term postkeratoplasty astigmatism. Trephination with high energy densities may induce thermal epithelial alterations when metal aperture masks are used. • Methods: Ninety porcine eyes fixed in an artificial anterior chamber (20 mmHg) were trephined with a 193-nm excimer laser in order to study the effect of the temperature on the cornea and the aperture mask during and after termination of the laser exposure. Energy levels tested were in the range used in patients. A pyroelectric infrared sensor connected to a PC via an analog-digital converter was used. With a high-speed sampling routine written inC++ it was possible to monitor on line the temperature in a focus 0.8 mm in diameter. • Results: In donor trephination the maximum temperature increase of the metal mask was 11 K (donor tissue 6.1 K, repetition rate 30/s). During recipient trephination the maximum temperature increase of the mask was 9.4 K (7.5 K on the cornea). An increase in the repetition rate and a decrease in the rotation speed resulted in greater temperature increase of the exposed cornea or metal mask. • Conclusions: Online monitoring of cornea and mask surface temperatures during excimer laser trephination is possible using high-speed sampling equipment. Appropriate adjustment of repetition rate and rotation speed may reduce thermal effects, especially in donor trephination.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0423
    Keywords: Key words Penetrating keratoplasty • Corneal ; topography • Astigmatism • Excimer laser trephination • Fourier analysis ; Schlüsselwörter Perforierende Keratoplastik • Topographie der Hornhaut • Astigmatismus • Excimer- Laser-Trepanation • Fourier-Analyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Hintergrund: Die semiquantitative Klassifizierung der Hornhauttopographie nach perforierender Keratoplastik bietet die Möglichkeit, neben dem keratometrischen oder topographischen Astigmatismusbetrag gebündelt Information über die flächige Brechkraftentwicklung der Hornhaut zu erhalten. Ziel der Studie war, den subjektiven semiquantitativen Prozeß der Klassifizierung auf der Basis von Fourier-Koeffizienten zu objektivieren und mit der subjektiven Klassifizierung zu korrelieren. Patienten und Methode: 50 Patienten (30 mit Keratokonus, 20 mit Fuchsscher Dystrophie) unterzogen sich einer nichtmechanischen Trepanation (Excimer-Laser MEL60, Aesculap-Meditec, Jena) im Rahmen einer perforierenden Keratoplastik. Alle Eingriffe (7,5 mm Trepanationsdurchmesser bei Fuchs, 8,0 mm bei Keratokonus, doppelt fortlaufende 10–0-Nylonnaht) wurden von demselben Operateur durchgeführt, prä-, intra- sowie postoperative Behandlung waren identisch. Im postoperativen Verlauf wurde der keratometrische Netto-Astigmatismus, die automatisierte Hornhauttopographieanalyse qualitativ und quantitativ sowie die Sehschärfe und Refraktion erfaßt. Die Hornhauttopographie wurde manuell semiquantitativ und auf der Basis von Fourier-Koeffizienten klassifiziert. Ergebnisse: Nach einer Beobachtungsdauer von 24 ± 5 Monaten stabilisierte sich der keratometrische Netto-Astigmatismus bei 3,0 bzw. 2,7 Dioptrien bei Keratokonus bzw. Fuchsscher Dystrophie. Qualitativ zeigte die Hornhauttopographie eine Regularisierung im zeitlichen Verlauf im Sinne einer Tendenz hin zu höherer Orthogonalität der Doppelkeulenstruktur sowie zu geringerer Unsymmetrie der Brechkräfte in gegenüberliegenden Hemimeridianen. Die semiquantitative Klassifizierung zeigte eine statistisch sichere Übereinstimmung mit der Klassifizierung auf der Basis von Fourier-Koeffizienten, besonders bei hohem Astigmatismus und nach Fadenentfernung (p = 0,04/0,01 vor/nach Fadenentfernung). Schlußfolgerung: Nach nichtmechanischer Keratoplastik läßt sich die semiquantitative Klassifizierung der Hornhauttopographie insbesondere bei höheren Astigmatismuswerten mit hoher statistischer Sicherheit aus den Fourier-Koeffizienten ableiten. Zukünftig könnte dieses Verfahren zur Abschätzung des potentiellen Visus nach Keratoplastik beitragen.
    Notes: Background: Semiquantitative classification of corneal topography after penetrating keratoplasty has the potential for focusing information about the areal dioptric power of the cornea. The purpose of this study was to objectify the procedure of manual semiquantitative classification using a Fourier transform of corneal topography power data and to correlate both methods. Patients and methods: Fifty patients each (30 keratoconus, 20 Fuchs dystrophy) underwent nonmechanical trephination (excimer laser MEL60, Aesculap-Meditec, Jena) in penetrating keratoplasty. All procedures (7.5-mm trephination diameter in Fuchs, 8.0 mm in keratoconus, double-running 10–0 nylon suture) were done by one surgeon. Pre-, intra- and postoperative treatment were identical. At the follow-up examinations, the keratometric astigmatism, qualitative and quantitative criteria of the automatic videokeratography, visual acuity and refraction were assessed. Corneal topography was classified both manually and based on Fourier coefficients. Results: After a mean follow-up of 24 ± 5 months, keratometric net astigmatism was 3.0 and 2.7 D with keratoconus and Fuchs dystrophy. Corneal topography analysis showed a higher orthogonality of the bow-tie shape and less asymmetry between opposite hemimeridians with increasing follow-up after keratoplasty. The semiquantitative classification showed a statistically significant correlation with the classification based on Fourier coefficients, especially with higher astigmatism and after suture removal (P = 0.04/0.01 before/after suture removal). Discussion: After nonmechanical trephination, the semiquantitative classification of corneal topography can be synthetized using Fourier analysis of corneal dioptric power data. In the future, this method may be favored for prediction of potential best-corrected visual acuity after penetrating keratoplasty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-0423
    Keywords: Key words Penetrating keratoplasty • Immunologic graft reactions • Nonmechanical trephination • Excimer laser • Irreversible endothelial decompensation ; Schlüsselwörter Perforierende Keratoplastik • immunologische Transplantatreaktionen • nichtmechanische Trepanation • Excimerlaser • irreversible Transplantateintrübung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Hintergrund: Die nichtmechanische Hornhauttrepanation ist heute in unserer Klinik das Standardverfahren bei der perforierenden Keratoplastik (PK) zur Therapie avaskulärer Hornhautprozesse und wurde bisher bei 400 Augen erfolgreich durchgeführt. Ziel der Studie war die Analyse der Häufigkeit und Reversibilität immunologischer Transplantatreaktionen nach nichtmechanischer Trepanation sowie deren Einflußgrößen. Patienten und Methoden: Im Zeitraum von 07/1989 bis 09/1997 gingen 286 konsekutive Operationen mit ausreichender Beobachtungsdauer in die Studie ein (104 × Keratokonus, 78 × Fuchssche Dystrophien, 31 × bullöse Keratopathien, 28 × akute Ulzera, 25 × avaskuläre Narben, 12 stromale Dystrophien, 4 × Buphthalmus, 4 × sonstige; 202 × alleinige PK, 84 × kombinierte Eingriffe; 276 Erst-PK). Das Operationsalter der 138 Frauen und 148 Männer schwankte zwischen 16 und 89 (im Mittel 55 ± 19) Jahren. Die Empfänger- und Spendertrepanation wurde mittels eines 193 nm-Excimerlasers (MEL50 bzw. MEL60, Aesculap-Meditec, 1,5 × 1,5 mm Punktprofil, 16–24 mJ/Puls, Repetitionsrate 30 bzw. 25/s; Metallmasken) von epithelial durchgeführt. Die Empfängertrepanation war entweder rund mit 4 bzw. 8 „Orientierungszähnchen bzw. -kerben“ (n = 251; 5,0 bis 8,0 mm Durchmesser) oder elliptisch (n = 35, 6,0 × 7,0 bis 7,5 × 8,5 mm Durchmesser). Bei 62 % der Operationen wurde frisches bzw. kurzzeitkonserviertes, bei 38 % organkultiviertes Spendergewebe verwendet. Ergebnisse: Insgesamt ereigneten sich während einer mittleren Beobachtungsdauer von 22 ± 18 Monaten (maximal 7,7 Jahren) 10 akute diffuse (davon 3 (1,0 %) irreversibel) und 3 chronische fokale endotheliale Transplantatreaktionen (4,5 %) frühestens 4 Monate und spätestens 35 Monate nach PK. Bei Elektiveingriffen war die Gesamtrate (3,5 %) signifikant (p = 0,01) geringer als bei Ulzera (14,3 %). Nach 1, 2 bzw. 3 Jahren war bei 1,3 %, 6,3 % bzw. 13,9 % der Elektiveingriffe eine Transplantatreaktion aufgetreten (Kaplan-Meier-Werte), jedoch nach keiner der 26 elliptischen Trepanationen. Bei kurzzeitkonserviertem Spendergewebe (4,2 %) traten die Reaktionen nicht signifikant häufiger, jedoch früher (12 ± 6 Monate) als bei organkultiviertem Gewebe (2,2 %, 30 ± 6 Monate) auf. Bei Keratokonus (4,9 %) ereigneten sich die Reaktionen häufiger (p = 0,05, LogRank) und früher als bei Fuchsscher Dystrophie (1,3 %). Schlußfolgerungen: Im historischen Vergleich scheint die nichtmechanische Trepanation neben optischen Vorteilen immunologisch zumindest keine Nachteile zu haben.
    Notes: Background: Nonmechanical trephination has been established as the standard procedure in penetrating keratoplasty (PK) for avascular corneal diseases at our institution. The purpose of this study was to analyze the incidence and reversibility of immunologic graft reactions after nonmechanical trephination and to detect potentially causative factors. Patients and methods: Out of a total series of 400 nonmechanical PKs, 286 consecutive procedures with sufficient follow-up performed between 07/1989 and 09/1997 were included in the study (104 × keratoconus, 78 × Fuchs' dystrophies, 31 ×bullous keratopathies, 28 × ulcers, 25 × avascular scars, 12 × stromal dystrophies, 4 × buphthalmos, 4 × others; 202 × PK only, 84 × combined procedures; 276 first PK). The age of the 138 females and 148 males at the time of surgery ranged from 16 to 89 (mean 55 ± 19) years. The recipient and donor trephinations were performed from the epithelial side using an 193-mm excimer laser (MEL50 or MEL60, Aesculap-Meditec, 1.5 ×1.5 mm spot mode, 16–24 mJ/pulse, repetition rate 30 or 25/s; metal masks). The shape of the recipient trephination was either circular with four or eight “orientation teeth” (n = 251; 5.0–8.0 mm diameter) or elliptical (n = 35, 6.0 × 7.0 to 7.5 × 8.5 mm diameter). In 62 % of procedures fresh or short-term-preserved donor tissue was used, and in 38 % of procedures the donor tissue was organ-culture-preserved. Results: During a mean follow-up of 22 ± 18 months (maximum 7.7 years), 10 acute diffuse (3 irreversible; 1.0 %) and 3 chronic focal endothelial graft reactions occurred (4.5 %) not earlier than 4 months and not later than 35 months after PK. Elective procedures (3.5 %) resulted in significantly (P = 0.01) less reactions than acute corneal ulcers (14.3 %). After 1, 2 and 3 years, the cumulative reaction rates (Kaplan-Meier values) were 1.3 %, 6.3 % and 13.9 % in elective procedures, none of which, however, occurred after 26 elliptical trephinations. With fresh or short-term-preserved donor tissue (4.2 %), graft reactions did not happen more frequently but earlier (12 ± 6 months) than with organ-culture-preserved donor tissue (2.2 %, 30 ± 6 months). In patients with keratoconus (4.9 %), reactions occurred more frequently (P = 0.05, LogRank) and earlier than in patients with Fuchs' dystrophy (1.3 %). Conclusions: In addition to well-established optical advantages, nonmechanical trephination seems to have no immunologic drawbacks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1433-0423
    Keywords: Schlüsselwörter Hornhautendothel ; Spiegelmikroskopie ; Automatisierte Videobildanalyse ; Reliabilität ; Validität ; Key words Corneal endothelium ; Specular microscopy ; Automated video image analysis ; Reliability ; Validity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Purpose: This prospective study was designed to test the reproducibility of a new automated technique for analyzing the corneal endothelium and to assess the validity of the technique by comparing it with a standard method. Subjects and methods: We used a contact specular microscope combined with a video camera (Tomey EM-1000) and a computer (IBM compatible PC, 486DX33) with suitable software (Tomey EM-1100, version 0.94). Video images of the corneal endothelium (area: 0.312 mm2) were passed directly into the computer input by means of a frame grabber and were automatically processed. The area to be analyzed could be varied by location and size (5580 – 135,150 µm2), depending on the quality of the image. Healthy corneas of 67 volunteers (age: 30.9±8.6 years) were examined. One examiner measured cell density three times in each of 42 eyes (retest-stability); three different examiners made one measurement in each of 25 eyes (objectivity). We evaluated the cell density determined by the computer after automated analysis and assessed the corrected cell density. This second result was obtained after the examiner had corrected the processed image by drawing in cell boundaries that the computer had not recognized or erasing cell boundaries the computer had sketched in by mistake. Additionally, a photograph of the corneal endothelium (specular microscope Bio Optics LSM 2000 A) was obtained from 40 volunteers to be used for manual cell counting applying a ,,fixed-frame`` technique (validity). Results: The corrected values showed a high retest-stability (reliability coefficient r = 0.943) and a high objectivity (r = 0.904). The values obtained by the automated method (2415±214 cells/mm2) did not differ significantly from those obtained by manual cell counting (2431±228 cells /mm2) (P = 0.898). The uncorrected values (2252±190 cells/mm2) were on average 7.2±2.6% lower than the corrected ones (177±69 cells/mm2). Retest-stability (r = 0.856) and objectivity (r = 0.737) of the uncorrected values were satisfactory. The uncorrected value was significantly lower than the value of manual cell counting (P〈0.001). The size of the analyzed area (range 12,750 – 84,708 µm2; average 31,438±10,655 µm2) had no significant effect on cell density (Spearman's correlation coefficient k = –0.150, P = 0.093). Conclusion: The automated method for analyzing the corneal endothelium quickly produces valid, reproducible results in normal corneas, provided that the correction mode of the software is applied.
    Notes: Ziel dieser prospektiven Studie war die Prüfung der Reproduzierbarkeit eines automatisierten Verfahrens der Hornhautendothelanalyse und die Beurteilung seiner Validität im Vergleich zu einer Standardmethode. Personen und Methoden: Verwendet wurde ein Kontaktspiegelmikroskop mit integrierter Videokamera (Tomey EM-1000) und ein Computer (IBM kompatibler PC, 486DX33) mit zugehöriger Software (Tomey EM-1100, Version 0.94). Grundprinzip des Verfahrens ist die direkte Überführung eines Videoendothelbilds (Fläche: 0,312 mm2) in ein digitalisiertes Computerbild und dessen automatisierte Prozessierung unter Umgehung einer Filmvorlage. Die Methode wurde bei 67 Probanden mit unauffälliger Hornhaut (Alter: 30,9±8,6 Jahre) angewendet. Bei 42 Normalprobanden wurde die Zelldichte 3mal von demselben Untersucher (Retest-Stabilität), bei 25 Probanden je 1mal von 3 verschiedenen Untersuchern (Objektivität) bestimmt. Festgehalten wurden der nach Analyse des Rohbilds vom Rechner ermittelte Zelldichtewert sowie ein 2. Wert nach Korrektur des prozessierten Bilds durch den Untersucher. Zusätzlich wurde die Endothelzelldichte anhand von Photographien (Spiegelmikroskop Bio Optics LSM 2000 A) in Fixed-frame-Technik durch manuelles Auszählen ermittelt (Validität). Ergebnisse: Bezüglich der korrigierten Zelldichtewerte waren sowohl die Reteststabilität (Reliabilitätskoeffizient r = 0,943) als auch die Objektivität (r = 0,904) hoch. Die Werte der automatisierten Methode (2415±214 Zellen/mm2) und nach manuellem Auszählen (2431±228 Zellen/mm2) waren nicht signifikant verschieden (p = 0,898). Die mittlere Abweichung betrug 3,3±2,4%, wobei keine systematische Abweichung in eine Richtung vorlag. Die unkorrigierten Zelldichtewerte (2252±190 Zellen/mm2) lagen im Mittel um 7,2±2,6% unter den korrigierten. Bezüglich der unkorrigierten Werte waren die Reteststabilität (r = 0,856) und die Objektivität (r = 0,737) zufriedenstellend. Der unkorrigierte Wert war gegenüber dem durch manuelles Auszählen ermittelten Wert signifikant erniedrigt (p〈0,001). Schlußfolgerung: Das getestete Endothelanalyseverfahren liefert bei normaler Hornhaut schnell zuverlässige und reproduzierbare Ergebnisse, vorausgesetzt, daß vom Korrekturmodus der Software Gebrauch gemacht wird.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  · Background: A study was carried out to evaluate the potential suitability of a free-running erbium:YAG 2.94-µm laser for trephination of human corneas in penetrating keratoplasty. · Methods: Two human donor corneas were placed in an artificial anterior chamber and moved with an automated rotation device (one rotation per minute). An erbium:YAG laser beam (pulse duration 400 µs, repetition rate 2/s, energy density 2.5 and 15.0 J/cm2) was focused on the outer edge of a round ceramic mask placed on the human donor corneas for ablation of tissue. · Results: With a fluence of 15.0 J/cm2, perforation was achieved after 500 pulses. Perpendicular central cut edges with mild stromal ridges and, by light microscopy, a 12 to 45-µm area of stromal thermal effects and focal endothelial changes up to 200 µm central to trephination were observed. · Conclusions: The erbium:YAG laser could be a promising ”low-cost alternative” to the excimer laser for nonmechanical trephination in penetrating keratoplasty. Further studies will have to focus on reduction of thermal damage and on wound healing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 237 (1999), S. 113-116 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  · Background: Photorefractive keratectomy (PRK) using the excimer laser is a well-established surgical technique for correction of mild to moderate myopic refraction errors in case of spectacle or contact lens incompatibility. As it is still uncertain whether this procedure causes intraocular inflammatory changes, it was the purpose of this study to quantify breakdown of the blood-aqueous barrier following PRK and to look for possible correlations with clinical parameters. · Patients and methods: Aqueous flare was quantified using the laser flare-cell meter after medical pupil dilation preoperatively and on days 1, 3 and 7 as well as 1 month and 3 months following PRK with a 193-nm excimer laser (MEL 60, Aesculap-Meditec) in 37 eyes of 22 patients. The preoperative spherical equivalents were −4.4±3.1 D (range −1.5 to −8.0 D). Pre-, intra- and postoperative treatment was standardized. · Results: Preoperatively, aqueous flare values were 3.9±0.8 photon counts/ms and showed no significant correlation with the spherical equivalent (p〉0.1). Postoperatively, aqueous flare rise was very small with flare values not significantly higher than preoperative values. All postoperative flare values were below the normal limit ( 〈8.0 photon counts/ms). Flare was highest on day 3 after PRK surgery. There was no statistically significant correlation between aqueous flare and depth of stromal ablation. The number of aqueous “cells” did not increase following PRK at any postoperative follow-up examination. · Conclusion: Our results indicate that PRK in mild to moderate myopia does not cause a significant breakdown of the blood-aqueous barrier.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...