Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Bending magnet beamline 9.3.2 at the Advanced Light Source (ALS) was designed for high resolution spectroscopy with the capability for delivering circularly polarized light in the soft x-ray energy region using three gratings. The monochromator is a fixed included-angle spherical grating monochromator (SGM) and was originally used at SSRL as a prototype for later insertion-device-based monochromators for the ALS. For operation at the ALS, the toroidal pre-mirror used at SSRL was replaced by a horizontally focusing and a vertically focusing mirror in the Kirkpatrick-Baez configuration. Circularly polarized radiation is obtained by inserting a water-cooled movable aperture in front of the vertically focusing mirror to allow selecting the beam either above or below the horizontal plane. To maintain a stable beam intensity through the entrance slit, the photocurrent signals from the upper and lower jaws of the entrance slit are utilized to set a feedback loop with the vertically deflecting mirror piezoelectric drive. The beamline end station has a movable platform that accommodates two experimental chambers enabling the synchrotron radiation to be directed to either one of the two experimental chambers without breaking the vacuum. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0168-9002
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Inst. and Methods in Physics Research, B 16 (1986), S. 244-250 
    ISSN: 0168-583X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Diabetologia 24 (1983), S. 326-329 
    ISSN: 1432-0428
    Keywords: Continuous subcutaneous insulin infusion ; insulin absorption ; half-time of insulin ; local insulin degradation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary One of the reasons for the variability of blood glucose regulation in Type 1 (insulin-dependent) diabetic patients is the huge variation in subcutaneous absorption of intermediate-acting insulin. We have investigated the variation in insulin absorption during continuous subcutaneous insulin infusion in eight such patients. The content of insulin in the subcutaneous tissue was measured using 125I-labelled insulin. The concentration of free serum insulin and blood glucose was followed from 1 h before and from 7 h after breakfast on two consecutive days. The amount of insulin absorbed during 24 h differed in all cases by less than 3% from the daily insulin dose given by the pumps. Mean insulin absorption rates and mean free insulin concentration showed peak values 30–90 min after meal bolus injections; this was sufficient to maintain near-normal blood glucose. Mean free serum insulin correlated strongly with disappearance of insulin from the subcutaneous tissue (r=0.98). From the insulin absorption rates and free insulin concentrations during basal constant insulin infusion, the half-time of serum insulin was calculated as 6 min. Compared with the known large variability in the absorption of intermediate-acting insulin, continuous subcutaneous insulin infusion offers a precise and reproducible way of insulin administration resulting in post-prandial serum insulin peaks sufficient to maintain near-normal blood glucose levels. The half-time of serum insulin during subcutaneous infusion corresponds to values for intravenous infusion given in the literature, indicating that local degradation of insulin in subcutaneous tissue is of minor importance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0428
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0428
    Keywords: Type 1 (insulin-dependent) diabetes mellitus ; HbA1c ; microalbuminuria ; insulin infusion pumps ; continuous subcutaneous insulin infusion ; blood pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We re-examined 69 of the 70 patients entering the two independent Steno Studies of effects of improved metabolic control on progression of late diabetic complications. They were analysed according to an intent to treat after follow-up for 8 years (Steno Study 1) and 5 years (Steno Study 2). The glycaemic control had improved in the insulin infusion group compared with the conventional treatment group (mean HbA1c) by 2.0±0.6% vs 0.7±1.2 in Steno Study 1 and by 1.8±1.2% vs 0.4±1.3 (p〈0.01) in Steno Study 2. In the insulin infusion groups three patients had died during episodes of ketoacidosis. These were not caused by malfunction of the insulin infusion pumps. In the conventional treatment groups, three patients suffered five cardiovascular events causing two deaths. From the sixth month of Steno Study 1 the annual change of the glomerular filtration rate was −3.7 (−5.4 to −2.0) ml·min−1·1.73 m−2 vs −1.0 (−2.1 to −0.1) (conventional vs insulin infusion group, mean (95% confidence interval, p〈0.01)). The change in urinary albumin excretion was associated with the glycaemic control (n=69, r=0.49, p〈0.0002). No progression was observed among 32 patients with low range microalbuminuria (30 to 99 mg/24 h). Among the 19 patients with an initial albumin excretion between 100 and 300 mg/24 h, progression of complications was more frequent during conventional treatment (n=10) vs insulin infusion (n=9): Clinical nephropathy (10 of 10 vs 2 of 9, p〈0.01) and arterial hypertension (7 of 10 vs 1 of 9, p〈0.01). The glomerular filtration rate declined during conventional treatment by −23 (−42 to −4) ml·mm−1·1.73 m−2 (p〈0.05) but not during insulin infusion (−13 (−31 to 5) NS). These results suggest that patients at risk of nephropathy should be offered near normal glycaemic control in order to preserve their kidney function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Diabetologia 17 (1979), S. 291-295 
    ISSN: 1432-0428
    Keywords: Insulin absorption ; intermediate acting insulin ; reactive hyperglycaemia ; Somogyi effect ; insulin dependent diabetes ; insulin therapy ; 125I-insulin ; Monotard insulin ; Isophane insulin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The absorption of monocomponent porcine125I-insulin Monotard and Isophane was studied in six insulin dependent diabetic patients over a period of 12 days. The absorption of insulin was measured as the disappearance of radioactivity from sites of injection. The daily125I-insulin doses ranged from 20 to 48 IU between patients. The insulin absorbed varied considerably within and between patients. The range of individual daily absorbed insulin varied from 19 to 104 per cent of the125I-insulin dose. A significant correlation (p〈0.05) was found between insulin absorption and blood glucose concentration. Insulin absorption rates were relatively high before all hypoglycaemic episodes and reactive hyperglycaemia was only observed when relatively low insulin absorption rates followed the hypoglycaemic attack. The results show that lability in some insulin dependent diabetics is explained by variation in insulin absorption.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Diabetologia 21 (1981), S. 161-162 
    ISSN: 1432-0428
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-0428
    Keywords: Long-term mean blood glucose concentration ; glycaemic control ; haemoglobin A1c ; Type 1 diabetes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Since glucose control and glycosylated haemoglobin varies asyncroneously, we have studied the steady-state relationship between these two factors. In Type 1 (insulin-dependent) diabetic patients with a constant haemoglobin A1c during the preceding 2 years, 15 ambulatory blood glucose profiles during a 5-week period showed a constant glucose level and provided a precise estimate of the mean blood glucose concentration. In addition, we studied 15 non-diabetic subjects who provided three glucose profiles and had one haemoglobin A1c determination performed. A good correlation was found for a curvilinear relationship (haemoglobin A1c=2.07 x mean blood glucose0.596, r=0.98). This close relationship indicates that glycosylated haemoglobin is a valuable, but not very sensitive, index of glucose control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...