Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 36 (1991), S. 240-243 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 35 (1990), S. 136-137 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 36 (1991), S. 329-331 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Achieving balanced electron–hole injection and perfect recombination of the charge carriers is central to the design of efficient polymer light-emitting diodes (LEDs). A number of approaches have focused on modification of the injection contacts, for example by incorporating an ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 249-253 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Schematic optimization approach ; Overlapping resolution mapping ; Nitroaromatics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of an interpretative optimization method to predict optimum conditions for the supercritical fluid chromatographic separation of nitroaromatics is demonstrated. The scheme utilizes the overlapping resolution mapping (ORM) procedure for multivariate prediction of the pressure gradient and temperature in order to separate eight nitroaromatics. Using the ORM scheme, only seven experiments were conducted before a global optimum was revealed. All the peaks were satisfactorily separated using experimental conditions derived from the scheme.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Microcolumn liquid chromatography ; C60 bonded phase ; Calixarenes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 15 (1994), S. 1273-1275 
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: The use of mixed surfactants for the separation of nine phenylthiohydantoin amino acids (PTH amino acids) by micellar electrokinetic chromatography (MEKC) was examined. The potential of a mixed surfactant system, consisting of cationic and anionic surfactants, for enhancing the selectivity of MEKC separations was explored. Both sodium dodecyl sulfate (SDS) and cetyltrimethylammonium bromide (CTAB) in the electrophoretic medium were found to improve the separation of the PTH-amino acids compared to the use of CTAB or SDS alone. Complete separation of the PTH amino acids was achieved using a buffer containing 2.5 mM CTAB and 40 mM SDS. The analysis was performed without the need to reverse the polarity of the electrodes, typically required if oppositely charged micelles are used. The migration behavior of the nine PTH amino acids using the mixed surfactant system was compared with MEKC in presence of SDS alone.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 16 (1995), S. 647-653 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Tumor necrosis factor ; Recombinant-DNA technology ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Capillary electrophoresis was used for the analysis of recombinant human tumor necrosis factor beta (rhTNF-β). Reproducible separation of the protein could be achieved in Polybrene-coated capillaries. Optimum conditions for separation were achieved with a pH 4.5 sodium acetate buffer. Besides Polybrene-coated capillaries, other commercially available column and column-coating reagents were also examined for the separation of rhTNF-β. Capillary electrophoresis was found to be a potentially useful method for product analysis and process monitoring in recombinant-DNA technology.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 18 (1997), S. 2024-2029 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Carbohydrates ; Enzyme electrode ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new approach to detect underivatized carbohydrates in capillary zone electrophoresis (CZE) with a bienzyme electrode is described. The bienzyme electrode is based on immobilization of two enzymes, glucose oxidase and amyloglucosidase, on a platinum microelectrode. Maltose and glucose were used as substrates to establish the method and study its feasibility. Using this electrode, underivatized glucose and maltose were determined after separation in 60 mM borate buffer (pH 9.3) by CZE. A liquid junction, between the surface of the bienzyme electrode and the outlet of the separation capillary, was used to lower the pH of the eluting separation borate buffer so that the immobilized enzymes could maintain high activities. The detection limits were 0.17 mM for maltose and 0.35 mM for glucose. The effects of borate ion and pH on the responses of the bienzyme electrode to maltose and glucose are discussed. The bienzyme electrode did not show any decay in responses to maltose or glucose during one week of continuous operation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 1719-1727 
    ISSN: 0173-0835
    Keywords: Micellar electrokinetic chromatography ; Octanol-water partition coefficient ; Pesticides ; Hydrophobicity ; Sodium cholate ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Micellar electrokinetic chromatography (MEKC) was evaluated as a new technique for the rapid estimation of octanol-water partition coefficient (logKow). Retention measurements for more than 40 reference pesticides with varied structural characteristics and hydrophobicity were carried out in two MEKC systems, based on sodium dodecyl sulfate (SDS) and sodium cholate (SC), respectively. To enable an accurate determination of capacity factors in the SC-MEKC system, cypermethrin (a synthetic pyrethroid insecticide) was utilized instead of Sudan III as the SC micelle tracer, since a few highly hydrophobic pesticides were found to elute after Sudan III. The linear correlation between logarithmic capacity factor (logk̃′1) and logKow in the two systems was examined. It was found that, under the typical buffer condition (10 mM sodium phosphate with 60 mM surfactant, pH 7.0), the SDS-MEKC system provided a somewhat wider dynamic range for hydrophobicity (logKow from -1.0 to 4.5). However, the correlation of logk̃′i with logKow was not very high when all the reference pesticides were included in one single calibration set. For the SC-MEKC system, the dynamic range for logKow was in the range of 1.0-5.5, and a good linear correlation existed between logk̃′i and logKow, even when all reference pesticides were incorporated into a single calibration group. By comparing the regression line of the reference pesticides with that of a group of simple aromatic derivatives, it was discovered that molecular size and functionality posed a less significant effect on the measurement of logKow in the SC-MEKC system than in the SDS-MEKC system. Thus, SC-MEKC shall be the system of choice for the estimation of logKow. The typical error on logKow determination using the current MEKC technique was within 0.5 units, suggesting that MEKC can be a valuable complement to reversed phase - high performance liquid chromatography (RP-HPLC) for the indirect determination of logKow. Besides maintaining all the advantages of the HPLC approach, the MEKC technique showed some unique benefits, such as better inter-column reproducibility, higher throughput, and less handling of toxic pesticides and solvents.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...