Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9673
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Analytical protocols have been adapted for the study of hydrocarbons at the trace level in the environment. Various samples, including sediments and biota, were collected from the Kuwaiti environment, treated according to the protocol and analyzed by chromatographic and spectroscopic methods. The methods used were synchronous scanning fluorescence spectroscopy (SSFS); high-performance liquid chromatography (HPLC) on C18 reversed-phase and NH2 normal-phase columns with UV and fluorescence detectors; gas chromatography on fused-silica capillary columns (GC) with flame ionization detector (FID), mass spectrometer (MS) and flame photometric detector (FPD); and high-resolution molecular spectrofluorimetry in Shpol'skii matrix at 10 K (HRSS). The different methods were found to give complementary information. SSFS was useful for fast evaluation and preliminary assessment of oil pollution during extended programs; it permitted sample selection for deeper analyses but, when applied to biota, needed special care in the clean-up procedure. GC/FID, was used to analyze saturated and ethylenic compounds and was useful for obtaining information on the origin of hydrocarbons but inconvenient for analyzing the aromatic fraction. GC/FPD was difficult to use with sediment samples and yielded little information on biota samples, although it did permit confirmation of high oil contamination in some examples. HPLC on a normal-phase column with UV and fluorescence detectors was useful for the fractionation of samples and for the separation of different families of aromatic compounds according to aromatic carbon number. GC/MS was used to quantify polycyclic aromatic hydrocarbons (PAHs) of less than four cycles but was not sensitive enough for PAHs of higher molecular weight. HRSS, however, was useful for the quantification of heavy PAHs and was also faster, could be automated, and gave accurate results. However, in an oil-pollution study, it must be backed up by the other techniques. In fact, no single analytical technique was found to be sufficient, and only judicious combinations of the tested techniques yielded adequate information on the origin of hydrocarbons in the environment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...