Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 100 (1994), S. 7984-7994 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The ionization and dissociation processes occurring after two-photon excitation of the d 1Σ+ state of NH have been investigated using one- and two-color multiphoton ionization spectroscopy in combination with mass-resolved ion and kinetic energy-resolved electron detection. The photoelectron spectra obtained for ionization of the molecule via the d 1Σ+ state (v'=0,1) reveal a one-photon ionization process to all energetically accessible vibrational levels of the X 2Π ground ionic state, at variance with a one-configuration description of the two states. Moreover, electrons are observed that derive from a one-photon ionization of excited neutral nitrogen and hydrogen atoms. Two-color excitation experiments of the d 1Σ+ state show that the influence of discrete states at the overall three-photon level on the dissociation dynamics is insignificant. Using the results of ab initio calculations it is concluded that these experimental observations can be interpreted consistently if two competing processes are assumed to take place from the d 1Σ+ excited state: a molecular one-photon ionization which is forbidden in zeroth order, and a two-photon nonresonance enhanced excitation to neutral (pre)dissociative states.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 100 (1978), S. 446-448 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-044X
    Keywords: Key words Anterior cruciate ligament • Biodegradable • Interference screw • Hamstring tendons • Mechanical testing ; Schlüsselwörter Vorderes Kreuzband • Semitendinosussehne • biodegradierbare Interferenzschraube • Biomechanik
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Verwendung von Semitendinosus-gracilis (STG)-Sehnentransplantaten beim Ersatz des vorderen Kreuzbands (VKB) stellt ein anerkanntes Verfahren dar. Vorteile wie eine geringe Transplantatentnahmemorbidität und Nachteile wie eine geringe Verankerungsfestigkeit und -steifigkeit wurden beschrieben. Kürzlich wurde gezeigt, daß eine ursprungsnahe Transplantatverankerung am ehemaligen Ansatz des VKB wesentlich dazu beiträgt, die vordere Kniestabilität und die Transplantat Isometrie zu erhöhen. Die direkte Interferenzschraubenverankerung der STG-Sehnen bietet dafür gute Voraussetzungen. Daten zur initialen Verankerungsfestigkeit liegen jedoch nicht vor. Daher wurde die Verankerungsfestigkeit eines Semitendinosussehnentransplantats, fixiert mit einer rundgewindigen Titan- und einer biodegradierbaren Interferenzschraube, in einem standardisierten Modell untersucht und die gewonnenen Daten mit denen der konventionellen Patellarsehnenverankerung verglichen. An 56 proximalen Kalbstibiae und humanen Semitendinosussehnen wurde die Ausreißkraft, das Eindrehmoment und die Verankerungssteifigkeit der direkten und der zusätzlichen Knochenblockverankerung eines 3-strängigen Semitendinosussehnentransplantats (STT) untersucht. Die Verankerungsfestigkeit einer biodegradierbaren rundgewindigen Poly (D, L-Laktid)-Interferenzschraube (Sysorb) (ohne Knochenblock: Gruppe I, mit Knochenblock: Gruppe II) und einer rundgewindigen Titanschraube (RCITM) (ohne Knochenblock: Gruppe III, mit Knochenblock: Gruppe IV) wurde verglichen. Als Kontrolle wurde die Verankerungsfestigkeit des Patellarsehnentransplantats (PT), fixiert mit der biodegradierbaren Poly (D, L-Laktid)-Schraube ((Gruppe V) und einer konventionellen Titaninterferenzschraube (Gruppe VI) bestimmt. Die Ausreißkraft des STT mit anhängendem Knochenblock (Gruppe II: 717 ± 90 N, Gruppe IV: 602 ± 117 N) war signifikant höher als bei der direkten (Gruppe I: 507 ± 93 N, Gruppe IV: 419 ± 77 N) Sehnenverankerung. Die Ausreißkraft des STT war jeweils unter Verwendung der biodegradierbaren Schraube signifikant höher. Die biodegradierbare Interferenzschraubenverankerung des STT mit anhängendem Knochenblock war nicht signifikant unterschiedlich zur PT-Verankerung (Gruppe V: 713 ± 210 N, Gruppe VI: 822 ± 130 N). Die Resultate der vorliegenden Untersuchung zeigen, daß die biodegradierbare Interferenzschraubenverankerung des STT der rundgewindigen Titanschraubenverankerung überlegen ist. Die Transplantatentnahme mit anhängendem tibialen Knochenblock kann die Verankerungsfestigkeit erheblich erhöhen und erreicht vergleichbare Werte zur Patellarsehnenverankerung. Diese Ergebnisse zeigen auf, daß biomechanische Nachteile herkömmlicher nicht anatomischer STG-Verankerungstechniken durch die Verwendung von Interferenzschrauben kompensiert werden können.
    Notes: Summary Anterior cruciate ligament (ACL) reconstruction using autologous hamstring tendons are being performed more frequently and satisfactory results have been reported. Advantages such as low donor site morbidity and ease of harvest as well as disadvantages like low initial construct stiffness have been described. Recently, it has been demonstrated that graft fixation close to the original ACL insertion sites increases anterior knee stability and graft isometry. Hamstring tendon fixation techniques using interference screws offer this possibility. To reduce the risk of graft laceration, a round threaded titanium interference screw (RCI) was developed. To improve initial fixation strength, fixation techniques for hamstring tendons with separate or attached tibial bone plugs were introduced. However, data on fixation strength do not yet exist. With respect to the proposed advantages of biodegradable implants, like undistorted magnetic resonance imaging, uncompromised revision surgery and a decreased potential of graft laceration during screw insertion, we performed pullout tests of round threaded biodegradable and round threaded titanium interference screw fixation of semitendinosus (ST) grafts with and without distally attached tibial bone plugs. Data were compared with bone-tendon-bone (BTB) graft fixation using biodegradable and conventional titanium interference screws. We used 56 proximal calf tibiae to compare maximum pullout force, screw insertion torque, and stiffness of fixation for biodegradable direct ST tendon and bone plug fixation (group I: without bone plug, group II: with bone plug) versus titanium interference screw fixation (group III: without bone plug, group IV: with bone plug). A round threaded biodegradable poly-(D, L-lactide) (Sysorb) and a round threaded titanium interference screw (RCI) were used. As a control calf bone-tendon-bone (BTB) grafts fixed with either poly-(D, L-lactide) (group V) or conventional titanium (group VI) interference screws were used. ST tendons were harvested either with or without their distally attached tibial bone plugs from human cadavers and were folded to a three-stranded graft. Specimen were loaded in a material testing machine with the applied load parallel to the long axis of the bone tunnel. Maximum pullout force of ST bone plug (group III: 717 N ± 90, group IV: 602 N ± 117) fixation was significantly higher than that of direct tendon (group I: 507 N ± 93, group III: 419 N ± 77) fixation. Maximum pullout force of biodegradable screw ST fixation was higher than that of titanium screw fixation in both settings. There was no significant difference in pullout force between biodegradable (713 N ± 210) and titanium (822 N ± 130) BTB graft fixation or between ST fixation with bone plug and biodegradable screw with BTB fixation. Pullout force of hamstring tendon interference screw fixation can be improved by using a biodegradable implant. In addition, initial pullout force can be greatly improved by harvesting the hamstring tendon graft with its distally attached tibial bone plug. This may be important, especially in improving tibial graft fixation. This study encourages further research in tendon-bone healing with direct interference screw fixation to confirm the potential of this advanced method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Der Chirurg 71 (2000), S. 1024-1033 
    ISSN: 1433-0385
    Keywords: Schlüsselwörter: Kreuzband ; biodegradierbar ; Doppelbündel ; Wachstumsfaktoren ; Navigation ; Robotik. ; Keywords: Cruciate ligament ; Biodegradable ; Double-bundle ; Growth factors ; Navigation ; Robotic technology.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract. Although long-term results in cruciate ligament surgery are continuously improving, we are still confronted with a certain rate of surgical failures and an increasing number of revision procedures. Despite a tremendous effort towards experimental and clinical research in the field of anterior and posterior cruciate ligament surgery over the past decades, there is still a strong need to further improve results. Therefore, the goal of the present paper is to introduce and discuss new developments in the rapidly changing field of cruciate ligament surgery, in order to give the clinician a base for discussion to include these developments in their daily clinical work. The present paper focuses on current developments and future perspectives such as biodegradable implants, new aspects in graft selection, double-bundle posterior cruciate ligament reconstruction, possibilities of biological intervention with growth factors, and the new technology of robotics and navigation.
    Notes: Zusammenfassung. Obwohl sich die Langzeitergebnisse nach Kreuzbandersatz laufend verbessern, werden wir nach wie vor mit einer gewissen Versagerquote und einer weiter steigenden Anzahl an Revisionseingriffen konfrontiert. Trotz intensivster experimenteller und klinischer Kreuzband-Forschung der letzten Jahrzehnte, ist der aktuelle Bedarf weiter sehr hoch, die Resultate in diesem operativen Gebiet reproduzierbar zu verbessern. Daher ist es das Ziel der vorliegenden Arbeit, neuste Entwicklungen in diesem sich rapide verändernden Feld vorzustellen und zu diskutieren. Dies hat das Ziel dem allgemein tätigen Kreuzbandchirurgen neue Denkanstöße zu geben, um diese in den klinischen Alltag mit einfließen zu lassen. Die vorliegende Arbeit versucht einen Einblick in neue Konzepte der Kreuzbandchirurgie, wie z. B. den Einsatz biodegradierbarer Implantate, neuere Überlegungen zur Transplantatauswahl und die Doppelbündel-Rekonstruktion des hinteren Kreuzbandes, kombiniert mit aktuellen Aspekten der biologischen Interventionsmöglichkeit durch Wachstumsfaktoren oder dem Einsatz von Robotik und Navigation zu geben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Azetabulumfraktur • Azetabulumtrümmerfraktur • Operative Behandlung • Erweiterter Zugang • 2-Jahres-Ergebnisse ; Key words Acetabular fractures • Complex acetabular fractures • Operative treatment • Extensile approach • Two-years follow-up
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Fourty-nine patients with 50 complex acetabular fractures were treated with open reduction and internal fixation from August 1993 to February 1996 in a prospectively documented study. The fractures were fixed with small fragment implants through a modified extensile iliofemoral approach (Maryland approach). Thirty-seven patients were polytraumatized with an ISS of 20 pts. on average. In 10 patients the ISS was 〉 25 pts. Good or anatomic initial fracture reduction with a fragment stepoff K 2 mm could be achieved in 48 fracturers (96 %). Thirty-six patients with 37 fractures could be evaluated after 25 months on average. In 28 fractures (76 %) the functional outcome was good or excellent according to the d'Aubigne and Harris scores. Radiological results were excellent in 21 fractures (57 %) and satisfactory in 12 fractures (Heeg score). In 7 cases (14 %) a postoperative subcutaneous seroma had to be treated surgically. No wound infections, however, were observed. Further complications were secondary a loss of reduction in 4 cases (11 %), relevant heterotopic ossifications (Brooker III/IV) in 5 cases (14 %), and aseptic femoral head necrosis in 2 cases (5 %). In two cases a total hip replacement (THR) for posttraumatic arthritis had to be performed. Two more cases are scheduled for THR due to symptomatic femoral head necrosis. A good joint reconstruction can be achieved through the modified extensile iliofemoral approach (Maryland) in complex fractures of the acetabulum. However, the approach related morbidity seems to be worrysome. In complex fractures with comminution in the roof of the acetabulum the prognosis remains uncertain even in cases where initial anatomic joint reconstruction can be achieved.
    Notes: Zusammenfassung In einer prospektiv begleiteten Studie wurden von August 1993 bis Februar 1996 49 Patienten mit 50 komplexen Azetabulumfrakturen über den modifizierten erweiterten iliofemoralen Zugang (Maryland) operiert und mit Kleinfragmentimplantaten stabilisiert; 37 Patienten waren polytraumatisiert mit einem mittleren ISS von 20 Punkten, bei 10 Patienten betrug der ISS 〉 25 Punkte. Bei 48 Frakturen (96 %) war die primäre Reposition anatomisch oder gut mit einer verbliebenen intraartikulären Stufenbildung von K 2 mm; 36 Patienten mit 37 Frakturen (76 %) konnten nach im Mittel 25 Monaten nachuntersucht werden. Bei 28 Frakturen (76 %) lagen gute oder sehr gute funktionelle Ergebnisse vor (d'Aubigné- bzw. Harris-Scores). Die radiologischen Ergebnisse waren bei 21 Frakturen (57 %) exzellent und bei 12 Frakturen (32 %) befriedigend (Heeg-Score). Komplikationen waren in 7 Fällen (14 %) therapiebedürftige subkutane Serome, in 4 Fällen (11 %) ein sekundärer Repositionsverlust, in 5 Fällen (14 %) heterotope Ossifikationen Grad III/IV (Brooker-Score) und in 2 Fällen (5 %) Femurkopfnekrosen. Bei 2 Frakturen wurde bei posttraumatischer Arthrose eine Hüfttotalendoprothese (TEP) implantiert, 2 weitere Frakturen mit Femurkopfnekrose sind zur TEP geplant. Über den modifizierten erweiterten iliofemoralen Zugang ist bei komplexen Azetabulumfrakturen eine anatomische Gelenkrekonstruktion in der Regel möglich. Die Zugangsmorbidität und Gesamtkomplikationsrate erscheint jedoch kritisch. Bei Frakturen mit Trümmerzonen im Azetabulumdach bleibt die Prognose auch bei initial guter Gelenkrekonstruktion im Einzelfall unsicher.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Traumazentrum • Vorhaltekosten • Polytraumaversorgung ; und -kosten ; Key words Trauma center • Polytrauma treatment and ; -costs • Financial aspect of trauma surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The treatment of severely injured patients is a challenge for preclinical and clinical treatment concepts, causing financial aspects of increasing importance for the German health care system. A total of 32,500 polytraumatized patients (PTS III and IV) are managed in trauma center levels I–IV in Germany. Trauma center levels I or II are by definition capable of supporting the full range of treatment for the severely injured. With the baseline calculation of 64,000 DM per patient and 104 polytrauma treated per year in the Berlin Virchow Clinic, 6.66 million DM primary costs must be spent for treatment. The total annual costs of this center are nearly 24 million DM for emergency cases and 7 million DM fixed costs per year, for a trauma center level I. In Europe the distribution of trauma center levels I or II is sufficient and can be specified with 1 center per 1 million inhabitants. Nevertheless, the european air medical service could support more intensive use of these central trauma institutions. This was shown by comparing the number of polytrauma patients and the number of trauma centers. Less then half of these patients are treated in levels I or II trauma centers. The financial pressure on the health system and the rising quality must lead to better utilization of trauma centers. To meet this goal a annual treatment rate of 300–400 polytrauma patients should be aimed at. The claim of the American College of Surgeons that a trauma surgeon should treat 50 severely injured patients per year would then be possible.
    Notes: Zusammenfassung Der schwerstverletzte Patient stellt höchste Anforderungen an die präklinische und klinische Behandlungskonzepte, wodurch entsprechend hohe Kosten entstehen. In Deutschland werden ca. 32.500 polytraumatisierte Patienten der PTS-Gruppe III oder IV in Krankenhäuser der Kategorie Grund- und Regelversorgung, der Schwerpunktversorgung und der Maximalversorgung, behandelt. Traumazentren werden dabei als Kliniken definiert, welche das gesamte Spektrum der Versorgung polytraumatisierter Patienten abdecken. Legt man nun Kosten von 64.000 DM pro Patient zugrunde, so entstehen z. B. bei 104 Polytraumen im Virchow Klinikum pro Jahr 6,66 Millionen DM primäre Behandlungskosten. Weiter ergibt sich, daß sich die Gesamtkosten dieses Traumazentrums für die Behandlung der Notfallpatienten auf 24 Millionen DM belaufen, mit reinen Vorhaltekosten gemäß Fixkostenrechnung von jährlich 7 Millionen DM. Setzt man einen Bedarf von 1 Traumazentrum pro 1 Million Einwohner voraus, so ist sowohl in Deutschland, als auch in vielen Ländern Europas eine flächendeckende Versorgung mit Traumazentren vorhanden. Dennoch könnte das europäische Luftrettungssystem die Auslastung zentraler Einrichtungen für die Versorgung polytraumatisierter Patienten intensiver unterstützen. Dies zeigt ein Vergleich der jährlich versorgten Polytraumen und der zur Verfügung stehenden Traumazentren, welcher belegt, daß weniger als die Hälfte der Polytraumen in Zentren versorgt werden. Unter Berücksichtigung der immensen Vorhaltekosten von Traumazentren und dem wachsenden finanziellen Druck auf das Gesundheitssystem müssen diese Zentren mehr genutzt werden. Sowohl unter dem Aspekt der Qualität als auch der zukünftigen Finanzierbarkeit, ist eine Versorgungsrate von 300–400 Polytraumen pro Jahr und Zentrum anzustreben. Dies würde auch der Forderung des American College of Surgeons entsprechen, wonach ein Traumachirurg pro Jahr 50 polytraumatisierte Patienten behandeln sollte.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1436-6274
    Keywords: Schlüsselwörter Unterarmschaftfraktur ; Fixateur interne ; Point-contact-Fixateur ; Key words Forearm fractures ; Internal fixation ; Point contact fixator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Fractures of the forearm are considered to be a very good indication for internal stabilisation, but conventional plating methods are technically demanding. A new method using the so-called point contact fixator (PC-Fix) applies internal fixation to splint overall reduced fractures rather than applying interfragmental and axial compression to precisely reduced fragments. It is easy and fast to use and results in few complications. In contrast to standard internal plate systems, which stabilise by friction, the PC-Fix design uses self-tapping, monocortical screws with angular stability that enable minimal implant contact to the bone, thus reducing perfusion underneath the implant. It must be noted that direct interfragmentary compression of the fracture is not always feasible with this system, which has been in use since 1993. Results were analysed in a prospective multi-centre investigation of 277 cases involving 387 diaphyseal fractures in 272 patients from 16 trauma centres worldwide. The fractures were stabilised surgically with the PC-Fix system. Twenty-one per cent of the fractures were open and 25% occurred in polytraumatised patients. Healing of all 355 fractures took place within 4 months and was uneventful. Overall, there were 32 complications before union occurred, and 27 of these bones (7%) required reoperation. The PC-Fix internal fixator is a simple and safe technique resulting in shorter duration of surgery and a low rate of complications.
    Notes: Der Point-contact-Fixateur (PC-Fix) ist eine Weiterentwicklung der konventionellen Plattenosteosynthese. Es handelt sich um einen neuen Fixateur interne zur Frakturstabilisierung. Die Kraftübertragung erfolgt dabei nicht wie bei konventionellen Plattensystemen durch Reibung, sondern durch eine winkelstabile, monokortikale Verankerung. Aufgrund dieser Eigenschaft können der Implantat-Knochen-Kontakt auf ein Minimum reduziert und die Knochenperfusion unter dem Implantat geschont werden. Das Implantat verfügt über selbstbohrende und selbstschneidende Schrauben in 3 verschiedenen Längen. Es ist zu beachten, daß eine direkte interfragmentäre Kompression der Fraktur mit dem Implantat nur eingeschränkt möglich ist. Das Implantat wird seit 1993 verwendet. In einer prospektiven multizentrischen Studie wurden 277 Unterarmschaftfrakturen in 272 Patienten mit 387 PC-Fix (387 gebrochene Radii und Ulnae) stabilisiert. 21% der Frakturen waren offen und 25% ereigneten sich bei polytraumatisierten Patienten. 251 der Unterarmschaftfrakturen heilten innerhalb von 4–6 Monaten mit ausgezeichnetem funktionellem Ergebnis. Es gab insgesamt 32 Komplikationen, von denen 27 eine Reoperation erforderten. Alle Frakturen heilten schließlich aus. Das PC-Fix-System zur Stabilisierung von Unterarmschaftfrakturen ist relativ leicht, schnell in der Anwendung und komplikationsarm. Dieses System stellt eine konsequente Weiterentwicklung von Implantatsystemen zur Schonung der Knochendurchblutung dar.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Human genetics 〈Berlin〉 22 (1974), S. 139-152 
    ISSN: 1432-1203
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Description / Table of Contents: Zusammenfassung Es wurde eine auslesefreie Gruppe von Neugeborenen im Vergleich zu einer Gruppe mit angeborenen Mißbildungen sowie einer Gruppe von Frühgeborenen cytogenetisch untersucht. Die Untersuchung von 2500 aufeinander folgenden Geburten ergab verschieden Chromosomenanomalien bei 19 Kindern (0.76%) und verschiedene Mikroanomalien ohne phänotypische Manifestation bei 38 Neugeborenen (1,52%). Die Häufigkeit von Chromosomenanomalien bei Neugeborenen mit erkennbaren, stärkeren oder geringeren Mißbildungen betrug 13,64%. Auf Grund unserer Ergebnisse und der Literaturdaten wurde die Häufigkeit der D-Trisomie (1:10000 Geburten) und der E-Trisomie (1:7500 Geburten) bestimmt. Frühgeborene zeigten eine hohe Häufigkeit von Abweichungen im Karyotyp. In somatischen Zellen Neugeborener fanden sich 1,32% Chromosomenaberrationen; dieser Wert betrug bei Frühgeborenen 7,39%; das wird auf Entwicklungsstörungen zurückgeführt. In somatischen Zellen fand sich eine Aneuploidiehäufigkeit von 4,13%. Der Chromosomenverlust war mit der Länge der Metaphasechromosomen eng korreliert; je kleiner ein Chromosom war, desto leighter ging es verloren. Es wurden einige allgemeine Grundsätze für die Durchführung populationsgenetischer Untersuchungen aufgestellt: a) Karyotypanalyse an einer Zellzahl, die auf Grund der Binomialverteilung festgelegt werden sollte, b) Nachuntersuchung aller Personen, bei denen ein Verdacht auf ein Mosaik vorliegt, c) Bestimmung des Geschlechtschromatins in Fällen mit Anomalien der Geschlechtschromosomen.
    Notes: Summary The cytogenetic study was undertaken of an unselected group of newborns, a group of newborns with congenital malformations, and a group of premature babies. The examination of 2500 consecutive births revealed various chromosome abnormalities in 19 infants (0.76%) and various chromosome microabnormalities with no phenotypic manifestations in 38 newborns (1.52%). The frequency of chromosome abnormalities in newborns with recognizable major and multiple physical congenital malformations was 13.64%. We used our findings and literature data to calculate the frequencies of D and E trisomies in the general population; they averaged 1:10000 and 1:7500 births respectively. A high frequency of karyotypic abnormalities was revealed in premature babies. The frequency of spontaneous chromosome aberrations in somatic cells of newborns was found to be 1.32%. The same index in premature babies appeared to be 7.39%, which is suggestive of the degree of environmental effect on the embryonal and fetal development. The frequency of aneuploidy in somatic cells was 4.13%. The loss of chromosomes correlated closely with their lengths in metaphase, the size of chromosomes being inversely proportional to the risk of loss. The general principles to be observed in conducting the population cytogenetic investigations with analysis of mosaicism were established: a) the karyotypic analysis of cells, the number being determined from Bernulli statistical design, b) reexamination of all individuals suspected of mosaicism, c) determination of sex chromatin in cases of sex chromosome abnormalities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Human genetics 〈Berlin〉 24 (1974), S. 115-128 
    ISSN: 1432-1203
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Description / Table of Contents: Zusammenfassung Es wurden Chromosomen aus peripherem Blut von Patienten mit Ataxia-telangiectasia untersucht. Dieses autosomal-recessive Erbleiden zeigt bei den Patienten die folgenden Manifestationen: progressive cerebelläre Ataxie; okulocutane Teleangiektasie; rekurrierende sinopulmonale Infektionen; ein IgA-Mangel; eine Verminderung der Zahl der T-Lymphocyten; eine geringe Blasten-Transformation der Lymphocyten. 3 Patienten zeigten eine lymphoreticuläre Neoplasie. Es wurden 2004 Zellen analysiert (49 Kulturen von 23 Patienten), von denen 151 Zellen (7,5%) eine Chromosomenaberration zeigten. Diese aberranten Zellen enthielten 168 Chromosomenbrüche (0,08/Zelle). Außerdem zeigte sich eine hohe Häufigkeit von Endoreduplikationen und Polyploidie. Bei 8 Patienten fanden sich Klone und Marker-Chromosomen: 46,Dq-; 46,t(Dq-Cq+); 46,t(Dq-Dq+) und 47,+C. Die Häufigkeit dieser Klone zu Beginn der Untersuchung war 5–10% bei verschiedenen Patienten. Nach 12 Monaten war die Häufigkeit auf 8–16% angestiegen. Entweder repräsentieren die markierten Klone einen Schritt in Richtung auf die lymphoide Neoplasie, für welche die Patienten disponiert sind, oder Proliferation abnormer Klone und Malignisierung sind zwei verschiedene Prozesse auf dem Hintergrund eines Immunglobulin-Mangels.
    Notes: Summary The peripheral blood chromosomes of patients with ataxia-telangiectasia were studied. The general manifestations of this autosomal recessive mutation in the examined patients were: a progressive cerebellar ataxia, oculocutaneous telanggiectasia, recurrent sinopulmonary infections, a deficit or lack of IgA, a diminished number of thymus-derived lymphocytes, and low lymphocyte blasttransformation. In 3 patients lymphoreticular neoplasia was diagnosed. 2004 cells were analyzed (49 cultures from 23 patients). 151 of these cells were found to have chromosomal aberration (7.5%). The aberrant cells contained 168 chromosomal breaks (0.08 per cell). A high frequency of endoreduplication and polyploidy was revealed in patients with ataxia-telangiectasia. Chromosomally marked clones were found in 8 patients. The types of clones were following; 46,Dq-; 46,t(Dq-Cq+); 46,t(Dq-Dq+) and 47,+C. The initial level of clones was 5–10% in different patients. The study after 12 months showed the increasing proportion of marked clones to 8–16%. Either the marked clones represent a step toward lymphoid neoplasia, to which the patients with ataxia-telangiectasia are predisposed, or proliferation of abnormal clones and malignization in such patients appear as two independent processes agianst a background of immunoglobulin deficit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    International orthopaedics 24 (2000), S. 143-147 
    ISSN: 1432-5195
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé  La fixation avec des vis corticales de taille 3,5 mm a été réalisée pour 51 fractures du cotyle (50 patients) à fragments suffisamment grands de 1992 à 1995. Il y avait 21 fractures simples et 30 fractures associées d’après la classification de Letournel. La plupart des patients souffraient de multiples lésions et un ISS moyen de 20 points a été enregistré. La voie d’abord de Kocher Langenbeck a été utilisée chez 9 patients et la voie ilio-inguinale chez 9 patients. La voie d’abord ilio-fémorale prolongée modifiée a été utilisée dans 31 des cas, et la voie iliocrurale élargie classique à deux reprises. Dans 40 fractures, une réduction anatomique a pu être atteinte avec un déplacement restant mesuré de moins de 1 mm. Un échec d’implant avec perte de réduction a été observé chez trois patients entraînant ainsi une re-opération. Lors des examens de suivi après 2 ans, 38/44 des patients avaient un excellent ou un bon résultat clinique et radiologique. Pour les fractures du cotyle à fragments suffisamment larges, la fixation avec des vis corticales de taille 3,5 mm a prouvéêtre une méthode adéquate pour obtenir une réduction anatomique et une rétention. Pour les fractures comminutives ou chez les patients à compliance réduite, une plaque d’appui supplémentaire est recommandée.
    Notes: Abstract  Between 1992 and 1995, 50 patients with 51 acetabular fractures underwent internal fixation using 3.5 mm cortical screws. There were 21 simple and 30 associated fracture types, as described by Letournel. Most of the patients had sustained multiple injuries with an average injury severity score (ISS) of 20 points. The modified extended iliofemoral approach was used in 32 cases, the Kocher Langenbeck approach in 9 cases, the ilioinguinal approach in 7 cases, the extended iliofemoral in 2 cases and the Kocher-Langenbeck approach combined with an ilioinguinal approach in a second stage procedure in 1. Anatomical reduction could be achieved with persistent displacement of no more than 1 mm in 40 fractures. Implant failure with loss of reduction occurred in 3 patients who underwent a revision procedure. At 2 year follow-up, 38 out of 44 of the patients had excellent or good clinical and radiological results. In acetabular fractures with sufficiently large fragments, screw fixation with 3.5 mm cortical screws proved satisfactory. In very comminuted fractures or where there is poor patient compliance an additional buttress plate should be used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...