Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1971
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1971
    Keywords: Aorto-pulmonary window ; Surgical technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The surgical treatment of aorto-pulmonary window by a closed technique is described. This avoids the increased risks of extracorporeal circulation and deep hypothermia with or without total circulatory arrest in the neonate or very sick infant.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 286 (1965), S. 171-180 
    ISSN: 1432-2013
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Using a microperfusion technique proximal tubular reabsorption of sulfamerazine, phenobarbital, p-aminohippuric acid, uric acid, sulfaurea and N4-acetylsulfamerazine was studied as a function of intratubular pH in the rat kidney in vivo. Transtubular permeabilities were related to in vitro lipoid solubility measurements and degrees of non-dissociation of the acids. It was found that 1. sulfamerazine and phenobarbital exhibit nonionic backdiffusion, the magnitude of which is dependent on lipoid solubility, 2. p-aminohippuric acid, uric acid and sulfaurea do not show this backdiffusion, a finding explained by lack of lipoid solubility, 3. N4-acetylsulfamerazine, despite relatively high lipoid solubility, is not reabsorbed in the proximal tubule.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 300 (1968), S. 35-48 
    ISSN: 1432-2013
    Keywords: Ammonia ; P nh 3 ; Cortical Nephron ; Permeability ; Acid-base ; Ammoniak ; Ammoniakdruck P nh 3 ; Corticaler Nierentubulus ; Permeabilität ; Säure-Basen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In Mikropunktions- und Mikroperfusionsuntersuchungen an der Rattenniere wurde der Ammoniakpartialdruck (P nh 3) im proximalen und distalen Tubulus und im Nierenvenenblut bestimmt. Zur Errechnung des P nh 3 wurden in Tubulusflüssigkeit und Nierenvenenblut Gesamtammoniakkonzentration (Berthelotsche Reaktion) und pH-Wert (Chinhydronelektrode) gemessen, wobei das Disäquilibrium-pH im distalen Tubulus (Rector et al., [17]) durch i.v. Infusion von Kohlensäureanhydratase ausgeschaltet war. Außer Punktionen im freien Fluß wurden Teile proximaler und distaler Rindenkonvolute mit ammoniakfreier kohlensäureanhydratasehaltiger Phosphatpufferlösung pH 6,30 durchströmt, die so zusammengesetzt war, daß keine transtubulären Wasser- und Elektrolytnettoflüsse stattfinden konnten. Längs des proximalen Konvoluts fällt der pH-Wert kontinuierlich von 7,22±0,10 (SD) auf 6,95±0,20 (SD) ab, während die Gesamtammoniakkonzentration von 0,20 auf 0,45 mM/l ansteigt. Bei Ratten mit Kohlensäureanhydratase-Infusion sind im distalen Konvolut der pH-Wert und die NH4-Konzentration nicht von den Werten am Ende des proximalen Konvolutes verschieden: pH-Wert 6,88±0,24 (SD), NH4-Konzentration 0,50 mM/l. Bei Ratten ohne Kohlensäureanhydratase-Infusion ist hingegen die Gesamtammoniakkonzentration im distalen Konvolut durchschnittlich 2,5fach höher. Dieser Befund ist durch das Vorliegen eines Disäquilibrium-pH im distalen Tubulus erklärbar. Innerhalb der Fehlerbreite der Methode wurde kein signifikanter Unterschied des P nh 3 zwischen proximalem (118±27·10−6 mm Hg) und distalem (121±29·10−6 mm Hg) Konvolut oder einzelnen Segmenten des proximalen Konvolutes gefunden. Die mittleren Werte des P nh 3 corticaler Tubulusflüssigkeit im freien Fluß waren nicht signifikant verschieden vom P nh 3 des Nierenvenenblutes (109±20·10−6 mm Hg) bei denselben Versuchstieren. Der P nh 3 der Durchströmungsflüssigkeit erreichte innerhalb 0,1–0,2 sec Perfusionszeit einen konstanten Wert, der im proximalen und distalen Konvolut gleich groß war (115±32 respektive 116±30·10−6 mm Hg) und mit dem P nh 3 der im freien Fluß entnommenen Tubulusproben gut übereinstimmte. Aus den Mikroperfusionsexperimenten geht hervor, daß die Permeabilität (P) der proximalen und distalen Tubulusmembran für Ammoniak sehr hoch ist, sie beträgt mehr als 1·10−2 cm/sec. Die Ergebnisse unterstützen die Hypothese, daß zwischen den verschiedenen Flüssigkeitsräumen der Nierenrinde keine mit den zur Verfügung stehenden Methoden meßbaren NH3-Druckdifferenzen bestehen.
    Notes: Summary The ammonia pressure (P nh 3) within the proximal and distal convoluted tubules was investigated in Charles River rats by micropuncture and microperfusion. P nh 3 was estimated on free-flow luminal fluid from total ammonia concentration (Berthelot reaction) and pH (quinhydrone electrode), development of disequilibrium pH being prevented in some experiments by simultaneous intravenous infusion of carbonic anhydrase. In free-flow the ammonia concentration rises and the pH decreases along the proximal convoluted tubule. Within the limits of error of the methods, no significant difference of P nh 3 was demonstrable between the distal (121±29·10−6 mm Hg) and proximal convolution (118±27·10−6 mm Hg) nor between successive segments of the proximal convolution, despite decline of pH of luminal fluid in the segments punctured. The mean value for P nh 3 of the cortical convolutions did not significantly differ from the P nh 3 of renal venous blood (109±20·10−6 mm Hg) estimated in the same experiments. Segments of proximal cortical convolutions and distal cortical convolutions were also perfused with an ammonia-free, carbonic-anhydrase-containing phosphate buffer solution at pH 6.30, compounded in such a way as to minimize net gain or loss of luminal water and sodium. Perfusate P nh 3 attained a constant value within 0.1–0.2 second, and the value was similar in proximal and distal convolutions (115±32 and 116±30·10−6 mm Hg respectively). The microperfusion data show that the permeability of the cortical nephrons to ammonia is very high (P = at least 1·10−2 cm/sec). All the data support the hypothesis that the several compartments of cortical water of rat kidneys are equilibrated to a near approximation with respect to P nh 3.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 290 (1966), S. 311-314 
    ISSN: 1432-2013
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung 1. Bei Äquilibrierung des ekkrinen menschlichen Schweißes mit einem Kohlensäurepartialdruck von 40 Torr ist der Schweiß stets sauer, wobei der pH-Wert mit zunehmender Schweißrate von 4,8 auf 5,8 ansteigt. 2. Ohne Äquilibrierung zeigen dieselben Schweißproben bei kleinen Schweißraten saure (pH 4,8) und bei hohen Schweißraten alkalische pH-Werte (pH 8). Dieser Befund wird dadurch erklärt, daß mit steigender Schweißrate die Milchsäurekonzentration abnimmt, während die Bicarbonatkonzentration zunimmt. 3. Die Gesamtammoniakkonzentration im Schweiß nimmt mit steigender Schweißrate von 8 auf 0,6 m Mol/l ab. 4. Die ausgeschiedene Gesamtammoniakmenge ist im gesamten Schweißratenbereich konstant (5±1) 10−4 μMol/Drüse · Std. Da der Ammoniakpartialdruck im Schweiß stets unter dem des arteriellen Blutes liegt, wird angenommen, daß Ammoniak passiv aus dem Plasma in den Schweiß diffundiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1615-6692
    Keywords: Schlüsselwörter Aneurysma ; Ductus arteriosus ; Angeboren ; Säugling ; Key Words Aneurysm ; Ductus arteriosus ; Congenital ; Infancy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract A congenital aneurysm of the ductus arteriosus Botalli was detected by chest X-ray as an intrathoracic mass in a 7-day-old infant. Following confirmation of the diagnosis by echocardiography and MRI the aneurysm was successfully resected via left lateral thoracotomy without cardiopulmonary bypass. The postoperative course was uneventful. Six years after operation the patient is asymptomatic and growing normally. An intrathoracic mass may be considered in the differential diagnosis especially in infants and children. Aneurysms of ductus arteriosus potentially are associated with serious complications. Timely diagnosis and early surgical intervention are decisive for prevention of serious complication and death.
    Notes: Zusammenfassung Wir berichten über ein angeborenes Aneurysma des Ductus arteriosus Botalli bei einem sieben Tage alten Neugeborenen. Auf einer Röntgenthoraxübersichtsaufnahme war es als intrathorakale Raumforderung aufgefallen, und nach Klärung der Diagnose durch MRT und Farb-Doppler-Echokardiographie war es durch eine linkslaterale Thorakotomie ohne Einsatz der extrakorporalen Zirkulation erfolgreich reseziert worden. Bei einer herznahen intrathorakalen Raumforderung sollte insbesondere bei Patienten im Neugeborenen- und Kindesalter differenzialdiagnostisch das seltene Aneurysma des Ductus arteriosus Botalli in Betracht gezogen werden. Nur durch eine frühzeitige Diagnose und rechtzeitige operative Therapie kann der mit der Zeit zunehmenden Gefahr von Komplikationen begegnet werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-0743
    Keywords: three-dimensional reconstruction ; transesophageal echocardiography ; mitral valve stenosis ; Doppler-echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D-echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D-echocardiographic data acquisition was performed by automatic transducer rotation at 2° increments over a span of 180°. The transesophageal probe was linked to an ultrasound unit and to a 3D-workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/ 3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes out of the 3D data set. The spatial position of the planes was indicated in a reference image. In the cross-sectional plane with the narrowest part of the leaflets the orifice area was measured by planimetry. For topographic information a 3D view down from the top of the left atrium was reconstructed. Measurements were compared to conventional transthoracic planimetry, to Doppler-echocardiographic pressure half time and to invasive data. The mean difference to transthoracic planimetry, pressure half time and to invasive measurements were 0.3 ± 0.1 cm2, 0.2 ± 0.1 cm2 and 0.1 ± 0.1 cm2, respectively. Remarkable differences between the 3D- echocardiographic and the 2D- or Doppler- echocardiographic methods were observed in patients with severe calcification or aortic regurgitation. In 22% of the patients the 3D data set was not of diagnostic quality. New diagnostic information from a 3D view of the mitral valve could be obtained in 69% of the patients. Thus, although image quality is limited, 3D- echocardiography provides new topographic information in mitral valve stenosis. It allows the use of a new quantitative method, by which image plane positioning errors and flow-dependent calculation is avoided.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗