Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry research 29 (1990), S. 988-994 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 68 (1996), S. 2804-2806 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The generation of hard-x-ray radiation ((h-dash-bar)ω≥25 keV) from short-pulse Ti:sapphire laser-produced plasmas is studied. Solid targets are irradiated by 0.2–10 ps laser pulses in the intensity range of 5×1013−5×1016 W/cm2. It is shown that the measured dose rates obey a simple scaling law. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-0743
    Keywords: three-dimensional reconstruction ; transesophageal echocardiography ; mitral valve stenosis ; Doppler-echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D-echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D-echocardiographic data acquisition was performed by automatic transducer rotation at 2° increments over a span of 180°. The transesophageal probe was linked to an ultrasound unit and to a 3D-workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/ 3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes out of the 3D data set. The spatial position of the planes was indicated in a reference image. In the cross-sectional plane with the narrowest part of the leaflets the orifice area was measured by planimetry. For topographic information a 3D view down from the top of the left atrium was reconstructed. Measurements were compared to conventional transthoracic planimetry, to Doppler-echocardiographic pressure half time and to invasive data. The mean difference to transthoracic planimetry, pressure half time and to invasive measurements were 0.3 ± 0.1 cm2, 0.2 ± 0.1 cm2 and 0.1 ± 0.1 cm2, respectively. Remarkable differences between the 3D- echocardiographic and the 2D- or Doppler- echocardiographic methods were observed in patients with severe calcification or aortic regurgitation. In 22% of the patients the 3D data set was not of diagnostic quality. New diagnostic information from a 3D view of the mitral valve could be obtained in 69% of the patients. Thus, although image quality is limited, 3D- echocardiography provides new topographic information in mitral valve stenosis. It allows the use of a new quantitative method, by which image plane positioning errors and flow-dependent calculation is avoided.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-0743
    Keywords: three-dimensional echocardiography ; aortic valve stenosis ; left ventricular outflow tract ; continuity equation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In 23 patients with aortic valve stenosis (14 male, 9 female, mean age 66 ± 21.5 years) left ventricular outflow tract cross-sectional area was determined in planimetric fashion using three-dimensional echocardiography. The 3-D data-set for each patient had been acquired in the course of a multiplane transesophageal examination. Aortic valve area was determined using the continuity equation. Results obtained were compared to those calculated by continuity equation using to the conventionally determined LVOT area (a = π [d/2]2). As reference method the results were compared to invasive measurements. 3-D planimetric determination of LVOT cross-sectional area was possible in 20 of 23 patients. In three patients, this method failed due to artefacts. The mean difference to the conventionally calculated LVOT area amounted to 0.18 cm2 (SD = 0.46). The comparison of AVA determined by continuity equation and by invasive measurement showed a mean difference of −0.074 cm2 (SD = 0.21) for the conventionally calculated LVOT area; for the planimetrically determined LVOT area the mean difference of AVA amounted to −0.03 cm2 (SD = 0.14) (p 〈 0.05). Planimetric determination of LVOT area using 3-D echocardiography improves the agreement of the continuity equation with invasive measurement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemical Engineering & Technology - CET 12 (1989), S. 374-378 
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Wall shear rate vectors in a bubble column and an airlift-loop reactor were measured using the limiting-current electrodiffusion technique. In connection with a new circular three-segment probe, the magnitudes and directions of shear rates were determined. The results for the bubble column are in good agreement with hot film-anemometry measurements in the same column. Moreover, the spiral flow structure, postulated in the shear-zone model of Franz, has been confirmed. In addition, the measuring technique was used to determine the flow structure in an airlift-loop reactor employed for the cultivation of animal cells. The region above the gas distributor of this fermenter has been identified as critical for mechanical damage to the cells.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 57 (1985), S. 139-141 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 57 (1985), S. 474-475 
    ISSN: 0009-286X
    Keywords: Blasensäule ; Hydrodynamik ; axiale Vermischung ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 59 (1987), S. 492-493 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 61 (1989), S. 70-71 
    ISSN: 0009-286X
    Keywords: Blasensäulenreaktoren ; Gas/Flüssigkeits-Zweiphasenströmung ; höherviskose Flüssigkeiten ; Meßtechnik, lokale Messungen ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Basic fibroblast growth factor (bFGF, FGF-2) is progressively lost from mammary epithelial cells as they become malignant. To investigate the effects of restoring the expression of bFGF in breast cancer cells, we constructed MCF-7 cells that permanently overexpress 18-kD cytoplasm-localizing bFGF (MCF-7/ΔAFGF(18) cells) and cells that express both the 18-kD along with the 22- and 24-kD nucleus-localizing bFGF peptides (MCF-7/NCFFGF(18,22,24) cells), using retroviral transduction. These stable cell constructs grew more slowly and had a larger fraction of their populations in the G0/G1 phase of the cell cycle than control cells. All forms of bFGF were eluted from MCF-7/NCFFGF(18,22,24) cell monolayers with 2 M NaCl, in contrast to fibroblasts that were demonstrated to secrete only the 18-kD bFGF isoform. High-affinity binding of 18-kD 125I-bFGF to these cells was significantly decreased, probably because of competitive binding by the autocrine-secreted bFGF. Recombinant 18-kD bFGF that was previously demonstrated in our laboratory to inhibit proliferation, activate MAP kinase, and induce the cyclin-dependent kinase inhibitor p21WAF1/CIP1 in MCF-7 cells, further inhibited MCF-7/ΔAFGF(18) cells but had no effect on MCF-7/NCFFGF(18,22,24) cells. The total cellular content of the high-affinity FGF receptors 1-3 was unchanged, but FGF receptor 4 was decreased in MCF-7/NCFFGF(18,22,24) cells. Both cell types overexpressing bFGF isoforms had elevated levels of the cyclin-dependent kinase inhibitor p27Kip1 but not that of p21WAF1/CIP1. In MCF-7/ΔAFGF(18) cells, FGFR1 and MAP kinase were constitutively phosphorylated. Exogenous recombinant 18-kD bFGF did not accentuate these effects but did induce an increase in the levels of p21WAF1/CIP1 corresponding to the further inhibition induced by exogenous bFGF in these cells. In MCF-7/NCFFGF(18,22,24) cells, FGFR1 and MAP kinase were not phosphorylated at baseline nor upon stimulation with recombinant bFGF, and exogenous bFGF only had a minimal effect on low steady-state p21WAF1/CIP1 levels. However, stimulation of these cells with phorbol ester or insulin did result in MAP kinase phosphorylation. While growth-inhibited in the G1 phase of the cell cycle, MCF-7/NCFFGF(18,22,24) cells retained active isoforms of cdk2 and the hyperphosphorylated form of Rb. These data suggest that high molecular weight forms of bFGF overexpressed in MCF-7 cells do not activate the receptor-mediated MAP kinase pathway, and do not induce p21WAF1/CIP1 in an autocrine manner, but inhibit proliferation through other, possibly direct nuclear signalling mechanisms. J. Cell. Physiol. 177:411-425, 1998. © 1998 Wiley-Liss, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...