Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 255-260 
    ISSN: 1741-0444
    Keywords: Aging ; Arteriosclerosis ; Autocorrelation ; Fourier analysis ; Photoplethysmography ; Pulse wave velocity ; Serum lipid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Pulse wave patterns at a finger and a toe are obtained using photoplethysmography. The data recorded at two recording sites are transformed by digital filters into six waveforms and the transmission time of each wave is estimated by the crosscorrelation function. Relationships between the transmission times, age, and parameters obtained from several laboratory tests are examined using multiple regression analysis. The results may be summarised as follows: the power of photoplethysmograms of a finger and a toe is concentrated in the range below 6 or 8 Hz; age correlates highly with the transmission time of a pulse wave rather than with velocity; the multiple correlation coefficients between age and the transmission times is 0·853 in male and 0·866 in female; there are no differences of transmission time among disease types; the correlations between age and other parameters measured by laboratory tests, that is, total cholesterol, phospholipid, triglyceride, β-lipoprotein, are very small.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 19 (1981), S. 257-261 
    ISSN: 1741-0444
    Keywords: Emergency medical service ; Man-machine interface ; Microprocessor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An intelligent terminal has been developed to provide the clinical staffs with a means of utmost simplicity to communicate with the computer. Only 16 keys and a single switch are all which are involved in any terminal operation. The members of the operating system are the interpreter of TEXTOR (a language developed in this study), editor, monitor, and data-communication handler. This system configuration greatly reduces the cost for data communication compared with the conventional communication systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...