Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 66 (1989), S. 5344-5348 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The diffusion of Be from buried Be-doped layers in GaInAs has been studied for temperatures between 600 and 700 °C. An interstitial-substitutional model is proposed for the diffusion mechanism, which is dependent on growth conditions and consistent with the data presented. Under growth conditions where Be transport is minimized GaInAs junction field-effect transistors have been produced with transconductances in excess of 200 mS mm−1 for a 1-μm gate length.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 10 (1987), S. 338-342 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Multi-element (52Cr, 56Fe and 66Zn) implanted GaAs samples have been prepared specially for SIMS calibration. Absolute chemical measurements gave retained ion doses which agreed to within 12% of the nominal implanted dose (2.0 × 1014 atoms cm-2). Comparative SIMS depth profiles with five instruments gave Cr mode depth data which showed a variability of 5%. After data normalization to a common mode depth (168 nm) the shape of all profiles showed good agreement. SIMS anàlysis of similar samples containing lower dose implants (1.0 × 1013 atoms cm-2) showed that ∼50% of the Cr was contained in the near surface region (0-0.03 μm). This surface peak was not observed in profiles of samples which had been singly implanted with Cr. It is proposed that the Cr surface peak results from radiation enhanced out-diffusion initiated by the subsequent Fe implant. Whilst the high dose multi-implant samples showed a similar Cr surface accumulation, its magnitude in relation to the ion implanted dose, was smaller. These samples therefore form reliable calibration specimens for the simultaneous determination of the secondary ion responses of Cr, Fe and Zn in GaAs.