Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Physiology 49 (1987), S. 533-543 
    ISSN: 0066-4278
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Medicine , Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 266 (1977), S. 703-704 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The linearly polarised 20 GHz beacon signal from the NASA ATS-6 geostationary satellite was received at the Bradford University Oxenhope Laboratory during the period October 1975 to July 1976, while the satellite was stationed at longitude 35 ?. At the receiving site (which is 450m above sea level) ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 208 (1965), S. 786-787 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Fig. 1. Ammo-nitrogen of y-keratose. , In water; O, in 0-2 M potassium chloride; f), in buffer, pH 10; 3, in buffer, j?H 4 With the exception of y-keratose under acid conditions, the amino-nitrogen value rose to a steady value over a period of time, the time depending on the pQ. of the solution. ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We have previously suggested that altering the height of the porous-coat segment of a partially porous-coated TiAl6V4 endosseous dental implant would affect the degree of crestal bone loss occurring during implant function by changing the patterns of stress transfer. This conclusion arose from the analysis of data from several different experiments and lacked a direct intra-animal comparison. In the present study we have compared two implant designs varying only in the extent to which they were porous-coated. With one design (type A) the coronal 1.8 mm of the implant root had a machined surface while the remainder of its length was porous-coated with TiAl6V4 beads. The other design (type B) had all but the coronal-most 0.75 mm porous-coated. Two implants of each type were placed in each of 4 dogs and the sites allowed to heal for 4 weeks before re-entry and prosthesis attachment. Monthly the implant-supported bridges were removed and radiographs exposed of each implant using a special film holder connected separately to each implant. These radiographs were analyzed for crestal bone loss using both direct visual and computer-assisted techniques. The results showed that bone remodelled to the machined surface-to-porous coat junction for type B implants and achieved a steady state by 12 weeks of function, whereas a longer time was required to achieve this state with type A implants. Significantly more bone loss occurred with the type A design, and this difference was detectable as early as after the first month of function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 7 (1996), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: It has previously been reported that porous-coated root form endosseous dental implants, became well integrated when used in the traditional 2-stage surgical approach. In this study, the placement of the implant in a 1-stage (non-submerged)technique was to be explored. Implants were placed in the mandibles of dogs, and 2 designs were used differing only in that one (experimental) had a 3mm transgingival extension, permitting it to be exposed lo the oral cavity from the outset. 12 (3 per animal) non-submerged implants were placed on I side of 4 beagle dogs and 12 control (submerged) implants were placed contralaterally. All implants were allowed to heal for 6 weeks, after which histological preparations were made. 2 of 12 non-submerged implants were lost due to post-operative complications: otherwise, all implants healed uneventfully. Histomorphometric analysis revealed bone-implant contact, as assessed by absolute bone contact (ABC) and contact length fraction (CLF). to be greater for the submerged design, suggesting that bone healing may be delayed with the non-submerged approach. As well. at this early stage of healing, for both implant designs, ABC and CLF were significantly greater on proximal than on buccal and lingual aspects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 467-483 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bone remodeling around three different endossesous dental implant designs placed in dog mandibles was studied using radiography during lengthy periods of function and by histology after animal sacrifice. The three designs investigated were (a) threaded (c.p. titanium), (b) fully porous-coated (titanium alloy), and (c) partially porous-coated (titanium alloy). The implants were kept in function for either 32 weeks (fully porous-coated) or 73 to 77 weeks (partially porous-coated and threaded). The studies indicated that some crestal bone loss occurred for both the threaded and partially porous-coated implants while no significant bone loss was seen with fully porous-coated implants in the absence of plaque-associated infection. It is suggested that these observed differences are a result of the different stress states that develop in bone surrounding the three designs underlying the importance of implant design on bone remodeling.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...