    ISSN: 0956-5663
    Keywords: enzyme electrode ; glucose oxidase ; glucose sensor ; implantation ; subcutaneous tissue
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Electrical Engineering, Measurement and Control Technology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1440
    Keywords: Sc. glucose concentrations ; Implantable glucose sensor ; In vivo testing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary An amperometric enzyme electrode and a wick technique were used for measurement of glucose in sc. tissue of sheep. When wicks were left implanted long enough to equilibrate with interstitial fluid, sc. glucose could have been reproducibly determined with the necessary accuracy. It was demonstrated that sc. tissue glucose concentrations in sheep are about 30% higher than in whole blood and are on the level of plasma glucose. This allows interpretation of sc. glucose sensor currents since results of in vitro-calibrations cannot be transferred to in vivo conditions. When an enzymatic sensor was implanted in the sc. compartment, the sensor signals were closely related to changes of blood glucose. These in vivo experiments indicate that short term glucose-monitoring with an subcutaneously implantable glucose sensor is feasible and so may provide a possible access to glycemic control. Further experiments will have to show, if glucose-controlled insulin infusions based on the output of a sc. glucose sensor will be able to maintain stable normoglycemia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0428
    Keywords: Continuous glucose sensing ; enzyme electrode ; glucose oxidase ; subcutaneous glucose concentration ; microdialysis ; oral glucose load
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary For the normalisation of blood glucose levels in diabetic patients by feedback controlled insulin delivery, a self-manageable and reliable method for continuous glucose estimation is still not available. By combining a commercially available needle type dialysis probe (molecular cutoff 20,000 Da) with a sensitive glucose sensor, we obtained a device for continuous glucose measurement in dialysate. This device was tested in healthy volunteers during a 75-g oral glucose tolerance test and in Type 2 (non-insulin-dependent) diabetic patients. Venous glucose and subcutaneous sensor signal were followed for 300 min (ten healthy subjects), 21 h (three healthy subjects) or 9 h (seven Type 2 diabetic patients). The recovery of the microdialysis was interindividually different, but after calibration, glucose levels in the dialysate and subcutaneous glucose sensor signal correlated well (r = 0.84–0.95). Under the assumption of a physiologic and technical delay between intravenous and subcutaneous glucose, correlation coefficient between intravenous glucose and subcutaneous sensor signal ranged from 0.60 to 0.93. We conclude that changes in blood glucose could be monitored in the subcutaneous tissue by the microdialysis technique in a continuous on line manner.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...