    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Defibrillation Efficacy. Introduction: Placement of implantable cardioverter defibrillators (ICDs) has been simplified by using the shell of a pectorally implanted ICD as a defibrillation electrode in combination with an endocardial right ventricular defibrillation lead. However, a sufficiently low defibrillation threshold (DFT) cannot be obtained in a few patients. Therefore, alternative approaches were systematically tested in the Active Can versus Array Trial (ACAT). Methods and Results: In the first of two prospective randomized studies, the DFT of a subcutaneous left dorsolateral array anode introduced from a pectoral incision was compared to that of a standard active can anode in 68 patients. Intraoperatively, the DFT was determined twice in each patient using either the active can or, in patients with a subcutaneous array lead, once with all three fingers and once omitting the middle finger of the array. The second prospective randomized study included 40 patients. DFT also was determined twice in each patient using an active can in a left pectoral position as anode alone and combined with a left dorsolateral array electrode with two fingers. In ACAT I, stored energy at DFT decreased from 13.1 ± 7.7 J (active can) to 9.6 ± 6.1 J (three-finger array lead) (P = 0.04), impedance decreased from 53 ± 8 Ω to 40 ± 6 Ω (P 〈 0.0001). Omitting the middle finger of the array lead, stored energy at DFT increased by 0.9 J (P = 0.47) and impedance by 2 Ω (P 〈 0.0001). In ACAT II, DFT and impedance using an active can device were significantly lower when a two-finger array lead was added that decreased stored energy at DFT from 10.1 ± 5.2 J to 6.9 ± 3.9 J (P = 0.001) and impedance from 56 ± 5 Ω to 42 ± 5 Ω (P 〈 0.0001). Conclusion: In combination with a right ventricular defibrillation electrode, a left pectoral subcutaneous array lead improves defibrillation efficacy if used instead of, or in addition to, a left pectoral active can ICD device. Implantation of the array lead can be simplified by using two instead of three fingers, without a significant loss of defibrillation efficacy.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Primary Programming of Stability and Onset Criteria. Introduction: Inappropriate therapies are the most frequent adverse event in patients with implantable cardioverter defibrillators (ICDs). Most ICDs offer a stability criterion to discriminate ventricular tachycardia (VT) from atrial fibrillation and an onset criterion to discriminate VT from sinus tachycardia. The efficacy and safety of these criteria, if used immediately after implantation, is unknown. Methods and Results: In a case control study, 87 patients in whom stability and onset criteria had been activated immediately after ICD implantation were matched to 87 patients in whom these criteria had not been activated. The groups were matched for known predictors of inappropriate therapies. With stability and onset criteria off, 24 patients (28%) received inappropriate therapies due to atrial fibrillation (n = 14) or sinus tachycardia (n = 11); with stability and onset on, only 11 patients (13%) were treated by the ICD due to atrial fibrillation (n = 5) or sinus tachycardia (n = 7) (log rank: P = 0.029). Five patients suffered inappropriate therapies despite the fact that onset (n = 4) or stability (n = 1) criteria were not fulfilled once tachycardias continued for a prespecified duration. Only one patient experienced a failure to detect VT due to the onset criterion; none because of stability. Conclusion: The immediate use of stability and onset criteria after ICD implantation reduces inappropriate therapies due to atrial fibrillation and sinus tachycardia. Because of the potential for underdetection of VT, this approach should be limited to tachycardia rates hemodynamically tolerated by the patient.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...