Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2156-2158 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The output from an x-ray detector using a Chevron pair of microchannel plates has been linearly encoded using an artificial delay line technique. The detector, operating in the wavelength region 12–30 A(ring), has been mounted on the focusing plane of a Johann crystal spectrometer, radius 25 cm, and used to survey the spectrum from the Divertor Injection Tokamak Experiment (DITE) tokamak. The 20×20 mm2 detector is encoded by a remote, CAMAC based, computer acquisition system which at an electronic count rate of 1×105 Hz shows negligible degradation of the spectral profiles. Events encoded along the 20-mm dimension are directly histogrammed into a CAMAC memory which is capable of recording 128 time frames each with 256 spectral bins with 12 bits/bin. In nonoptimized tests, a FWHM of 60 μm is observed, and a count rate up to 2×104 Hz/mm has been achieved. The high-resolution capability and the shallow detection depth of the microchannel plate both complement the low f number of the spectrometer. Results are reported for the DITE tokamak.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @Muslim world 15 (1925), S. 0 
    ISSN: 1478-1913
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Theology and Religious Studies
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 8 (2001), S. 1157-1161 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: X-ray magnetic circular dichroism studies of magnetic 3d transition-metal samples require the recording of high-quality absorption scans in high magnetic fields using circularly polarized soft X-rays of energies in the range 0.5–1 keV. Normally this is performed by electron yield measurements in vacuum. This technique is rendered problematic by the influence of the high magnetic field on the motion of the electrons emitted. Detection of the fluorescent X-rays avoids this problem and eases the constraints of sample preparation and environment. However, the specifications required for a successful X-ray detector are severe, requiring an insensitivity to magnetic fields up to 4 T (for hysteresis curve measurements), a large dynamic range, detection of soft X-rays with good efficiency and signal to noise and containment of the detector structure within a space of a few cm3. Such a detector has been developed using gas microstrip technology and tests show that these requirements can be met.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 7 (2000), S. 307-312 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Counting detector systems are increasingly used in X-ray experiments because of their attractive properties as regards linearity, large dynamic range and simple noise properties. In synchrotron radiation source (SRS) applications of X-ray detectors, counting rates are generally high enough to require dead-time correction. The time structure of an SRS beam interacts with the dead-time characteristics of the detector in a way that the simple stochastic dead-time models cannot always handle. This report generates analytical and Monte Carlo mathematical models which describe the rate performance of any given detector system when used with the typical beam structures encountered in an SRS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...