Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 66 (1983), S. 49-56 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents The characteristics of a sixpulse bridge converter with external commutation on the d.c. side are described. For that purpose the waveforms of currents and voltages are evaluated at first neglecting the impedances in the commutation circuits. Next the influence of these impedances on the commutation procedure, on the angle of overlap and on the direct current characteristic is considered. Harmonics in currents and voltages are investigated using some special assumptions. Finally the behaviour of the sixpulse bridge converter with external commutation on the d.c. side is evaluated when working with intermittent current on the a.c. side. The conditions for this operation mode are derived.
    Notes: Übersicht Es werden die wichtigsten Eigenschaften der Sechspuls-Brückenschaltung mit gleichspannungsseitiger Kommutierung beschrieben. Dazu werden zunächst die Strom-und Spannungszeitverläufe ohne Berücksichtigung von Impedanzen im Kommutierungskreis abgeleitet. Danach wird der Einfluß von Impedanzen im Kommutierungskreis auf den Kommutierungsvorgang, auf den Überlappungswinkel und die Steuerkennlinien untersucht. Weiter wird auf Spannungsund Stromoberschwingungen auf der Wechselstrom- und Gleichspannungsseite eingegangen. Es werden diese Oberschwingungen unter vereinfachenden Annahmen berechnet. Zum Abschluß wird auf den auch bei gleichspannungsseitiger Kommutierung auftretenden Lückbetrieb eingegangen. Es werden die Funktion der Schaltung im Lückbetrieb erläutert und die Bedingungen für das Auftreten von lückendem Wechselstrom angegeben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 65 (1982), S. 245-250 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents The characteristics of converters with natural commutation on the d.c. side are described using the example of a two pulse bridge connection. This type of converters was not evaluated very largely in the past compared to the converters with natural commutation on the a.c. side. In this paper the characteristics of the direct current and the commutation procedure are evaluated. This includes calculating the angle of overlap. The advantagous behaviour of this type of converters is shown when operating in the inverter mode. The equation of the angle of advance is derived. This equation is compared to that of the converter using natural commutation on the a.c. side. The influence of inductances in the commutation circuits on the average value of the direct current is shown. Some systematic remarks are made on single-way connections and double-way connections of converters using natural commutation on the d.c. side.
    Notes: Übersicht Die wichtigsten Eigenschaften von Stromrichtern mit natürlicher, gleichspannungsseitiger Kommutierung werden am Beispiel der Zweipulsbrückenschaltung beschrieben. Dieser Stromrichtertyp wurde in der Vergangenheit im Gegensatz zu den Stromrichtern mit natürlicher, wechselspannungseitiger Kommutierung kaum behandelt. Im vorliegenden Aufsatz wird auf die Bildung des Gleichstromes und den Kommutierungsvorgang einschließlich der Berechnung des Überlappungswinkels eingegangen. Das vorteilhafte Verhalten dieser Stromrichter im Wechselrichterbetrieb wird mit der Ableitung der Beziehung für den Voreilwinkel gezeigt. Diese wird mit der entsprechenden Beziehung für die Stromrichter mit wechselspannungsseitiger Kommutierung verglichen. Weiter wird auf den Einfluß der Induktivitäten im Kommutierungskreis auf den Mittelwert des Gleichstromes eingegangen. Für Stromrichter mit natürlicher Gleichspannungskommutierung wird schließlich eine Systematik der Schaltungen mit einer Einteilung in Einweg- und Zweiwegschaltungen angegeben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 81 (1999), S. 395-407 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents A static synchronous converter with an active damping circuit is introduced in its basic construction as well as in operation. The new concept is based on the known principle of the static reactive power converter, which was widened by system integration of largely standardized components of the drive converter-technology in its functional ability. The paper deals beside the system-technology above all with the structure and mathematical interpretation of a modular control concept for the use of power conditioning in power systems and the coherent network control in isolated operation.
    Notes: Übersicht Es wird ein Statischer Synchronkonverter mit aktivem Dämpferkreis in seinem grundlegenden Aufbau sowie Wirkungsweise vorgestellt. Das neue Konzept basiert auf dem bekannten Prinzip des statischen Blindleistungsstromrichters, welches durch Systemintegration weitgehend standardisierter Komponenten der Stromrichtertechnik in seiner Funktionsfähigkeit erweitert wurde. Der Aufsatz beschäftigt sich neben der Systemtechnik vor allem mit der Struktur und mathematischen Auslegung eines modularen Regelungskonzeptes für den Einsatz zur Energiekonditionierung in Verteilnetzen und der kohärenten Netzführung im Inselbetrieb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 81 (1998), S. 309-315 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Übersicht Ein Regelverfahren für Netzpusstromrichter wird vorgestellt, welches die Eigenschaften einer hochdynamischen Vektorregelung mit “off-line”-optimierten Pulsmustern verbindet. Die Optimierung der Pulsmuster kann dabei abhängig von den am Anschlußort vorherschenden Netzverhältnissen durchgeführt werden. Auch der Wechsel des optimierten Pulsmusters im Betrieb für die Adaption an sich ändernde Netzimpedanzen ist denkbar.
    Notes: Contents A control method for three-phase voltage source converters which combines the benefits of a highly dynamic vector control with “off-line”-optimized pulse patterns is presented. The pulse pattern optimization can be realized in accordance with the conditions of the local grid configuration. Furthermore, the control method allows the adaptive selection of different pulse patterns during operation in dependence of changing grid impedances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 81 (1998), S. 309-315 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Übersicht Ein Regelverfahren für Netzpulsstromrichter wird vorgestellt, welches die Eigenschaften einer hoch- dynamischen Vektorregelung mit “off-line”-optimierten Pulsmustern verbindet. Die Optimierung der Pulsmuster kann dabei abhängig von den am Anschlußort vorherrschenden Netzverhältnissen durchgeführt werden. Auch der Wechsel des optimierten Pulsmusters im Betrieb für die Adaption an sich ändernde Netzimpedanzen ist denkbar.
    Notes: Contents A control method for three-phase voltage source converters which combines the benefits of a highly dynamic vector control with “off-line”-optimized pulse patterns is presented. The pulse pattern optimization can be realized in accordance with the conditions of the local grid configuration. Furthermore, the control method allows the adaptive selection of different pulse patterns during operation in dependence of changing grid impedances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 81 (1999), S. 395-407 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents A static synchronous converter with an active damping circuit is introduced in its basic construction as well as in operation. The new concept is based on the known principle of the static reactive power converter, which was widened by system integration of largely standardized components of the drive converter-technology in its functional ability. The paper deals beside the system-technology above all with the structure and mathematical interpretation of a modular control concept for the use of power conditioning in power systems and the coherent network control in isolated operation.
    Notes: Übersicht Es wird ein Statischer Synchronkonverter mit aktivem Dämpferkreis in seinem grundlegenden Aufbau sowie Wirkungsweise vorgestellt. Das neue Konzept basiert auf dem bekannten Prinzip des statischen Blindleistungsstromrichters, welches durch Systemintegration weitgehend standardisierter Komponenten der Stromrichtertechnik in seiner Funktionsfähigkeit erweitert wurde. Der Aufsatz beschäftigt sich neben der Systemtechnik vor allem mit der Struktur und mathematischen Auslegung eines modularen Regelungskonzeptes für den Einsatz zur Energiekonditionierung in Verteilnetzen und der kohärenten Netzführung im Inselbetrieb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents This method for numerical and analytical calculations of magnetic fields emitted by low frequency eddy currents in conducting shielding material is based on the law of Biot-Savart as well as on the substitution of those eddy currents by short-circuited turns. It is suitable especially for field calculations for power electronic facilities of large, inhomogeneous geometry and defined conductors. The method may be applied in the calculation of conductor geometries and shielding measures in power converter facilities.
    Notes: Übersicht Die dargestellte Methode zur numerischen und analytischen Berechnung der Magnetfelder von in leitfähigem Schirmmaterial induzierten niederfrequenten Wirbelströmen basiert auf dem Gesetz von Biot-Savart sowie auf der Modellierung der Wirbelströme durch Kurzschlußschleifen. Sie eignet sich besonders für die Feldberechnung leistungselektronischer Anlagen mit räumlich ausgedehnten, inhomogenen Geometrien und ausgeprägten Stromleitern. Anwendung finden soll die Methode bei der Berechnung von Leiteranordnungen und Schirmmaßnahmen in Stromrichteranlagen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 357 (1997), S. 652-655 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract  The oxygen content of oxides such as SiO2, ZrO2, Fe2O3, Cr2O3, Co3O4, and of Cr-, Fe- and Co-doped ZrO2 was determined by carrier-gas-heat-extraction. Special attention was given to the accuracy and the precision of the results and to the behaviour of the samples during the process of thermal decomposition. A precision of 0.5 to 1% vol could be achieved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 39 (1983), S. 401-404 
    ISSN: 1600-5740
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Cell Biology International Reports 8 (1984), S. 193-205 
    ISSN: 0309-1651
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗