Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 202-204 
    ISSN: 0935-6304
    Keywords: GC×GC ; comprehensive two-dimensional GC ; thermal modulation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A jet of cool gas is used to locally cool a section of modulator tube in the presence of the stirred oven bath of a GC×GC instrument. Local cooling decouples the temperature of the modulator tube from that of the first dimension column, which was 100 meters long. Overall resolution of the GC×GC experiment was improved as a result. Another consequence of the jet-cooled thermal modulation structure is the elimination of moving parts in the GC oven. By pulsing cold and hot jets of gas onto a modulator tube with solenoid valves, two stage thermal modulation can be obtained without the complexity of moving parts in the vicinity of the capillary columns.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 205-207 
    ISSN: 0935-6304
    Keywords: GC×GC ; thermal modulation ; comprehensive three-dimensional GC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Comprehensive three-dimensional gas chromatography (GC3) is demonstrated using modified GC×GC apparatus. A new thermal modulation scheme employing a single moving heater to operate two thermal modulators is introduced. Considerations of the bandwidth/resolution tradeoff of GC3 show that high-speed tertiary columns would make GC3 practical, with modest loss of underlying GC×GC peak capacity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...