Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 36 (1990), S. 1151-1154 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 36 (1990), S. 1141-1150 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Based on the well-known mechanism describing Michaelis-Menten kinetics, three rate expressions may be developed: the exact solution (Model 1), a rate equation resulting from the pseudo-steady-state assumption (Model 2), and Model 2 with the additional assumption that the amount of free substrate is approximately equal to the total amount of substrate (Model 3). Although Model 1 is the most precise, it must be integrated numerically and it requires three experimentally determined parameters. Models 2 and 3, however, are simpler and require only two parameters. Using dimensionless forms of the three models, we have evaluated the errors in the two simplified models relative to the exact solution using a wide range of parameter values. The choice of model for reactor design depends on the initial substrate to enzyme ratio (α0), and on the ratio of the Michaelis-Menten constant to the enzyme concentration (σ). Based on a 2% model error criteria, when α0 〉 15 or σ ≥ 100, Model 3 is adequate; if 5 〈 α0 〈 15, or if σ ≥ 10, then Model 2 may be used; and if α0 〈 5 and σ 〈 10, then the exact solution (Model 1) is required.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...